• 제목/요약/키워드: Fire investigation data

검색결과 115건 처리시간 0.021초

열화된 저압용 콘센트에서 방전신호의 발생과 검출 (Generation and Detection of Discharge Signals in Deteriorated)

  • 송재용;서황동;문승보;길경석;조영진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.200-203
    • /
    • 2005
  • Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. In this paper, we have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using an aged concent to provide information on the characteristics of discharge signals. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600 kHz - 1.5 MHz in incomplete connections and at 210 kHz - 8 Mhz in deteriorations of the concent.

  • PDF

노말도데칸의 인화점과 최소발화온도 측정에 의한 연소위험성 고찰 (The Investigation of Combustible Hazard by Measurement of Flash Point and Autoignition Temperature of n-Dodecane)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.120-125
    • /
    • 2011
  • 노말도데칸의 안전한 취급을 위해서 25에서 폭발한계를 고찰하였고, 하부인화점과 발화지연시간에 의한 발화온도를 측정하였다. 공정의 안전을 위해서 노말도데칸의 폭발하한계는 0.60Vol.%, 상한계는 4.7Vol.%를 추천하였고, 하부인화점은 밀폐계에서 $77^{\circ}C$$80^{\circ}C$와 개방식에서 $84{\sim}87^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 최소자연발화온도는 $222^{\circ}C$ 측정되었다.

Investigation of the effect of internal curing as a novel method for improvement of post-fire properties of high-performance concrete

  • Moein Mousavi;Habib Akbarzadeh Bengar
    • Computers and Concrete
    • /
    • 제33권3호
    • /
    • pp.309-324
    • /
    • 2024
  • Internal curing, a widely used method for mitigating early-age shrinkage in concrete, also offers notable advantages for concrete durability. This paper explores the potential of internal curing by partial replacement of sand with fine lightweight aggregate for enhancing the behavior of high-performance concrete at elevated temperatures. Such a technique may prove economical and safe for the construction of skyscrapers, where explosive spalling of high-performance concrete in fire is a potential hazard. To reach this aim, the physico-mechanical features of internally cured high-strength concrete specimens, including mass loss, compressive strength, strain at peak stress, modulus of elasticity, stress-strain curve, toughness, and flexural strength, were investigated under different temperature exposures; and to predict some of these mechanical properties, a number of equations were proposed. Based on the experimental results, an advanced stress-strain model was proposed for internally cured high-performance concrete at different temperature levels, the results of which agreed well with the test data. It was observed that the replacement of 10% of sand with pre-wetted fine lightweight expanded clay aggregate (LECA) not only did not reduce the compressive strength at ambient temperature, but also prevented explosive spalling and could retain 20% of its ambient compressive strength after heating up to 800℃. It was then concluded that internal curing is an excellent method to enhance the performance of high-strength concrete at elevated temperatures.

델파이 기법을 활용한 화재피난 시나리오 개선 연구- 모바일 어플리케이션과 재실자 심리를 중심으로 - (A Study on the Improvement of Fire Evacuation Scenario Using Delphi Technique -Focus on The Mobile Application and psychology-)

  • 이상기;김성현
    • 서비스연구
    • /
    • 제12권2호
    • /
    • pp.23-37
    • /
    • 2022
  • 본 연구에서는 화재가 발생했을 때, 화재감지시스템과 연동된 모바일 어플리케이션의 도움을 받아 재실자들이 안전하게 피난할 수 있는 기존의 김태완 외3명(2018)이 제안한 서비스 시나리오를 토대로 1950년 RAND사가 개발한 다양한 전문가의 경험적 지식을 통한 문제해결을 하는 기법인 델파이 조사(Delphi Method)를 통해 좀 더 현실적인 시나리오를 작성하여 피난심리나 행동에 도움이 될 수 있는 모바일 자극을 접목하여 시나리오를 고도화하는 것이 최종 목적이다. 또한 제작되어지는 시나리오가 일반적인 건물의 구조와 동선까지 고려하여 좀 더 현실적으로 만들기 위해 전문가 시나리오검증과 델파이 기법을 적용하여 기존 시나리오에서 불필요하거나 현실적으로 실현이 어려운 부분을 제외 하였다. 연구 결과 1차 델파이 조사에서 화재경보 시에 보일 수 있는 주요 심리로 꼽혔던 것은 의구심, 안전불감, 경각심이었으며, 2차 델파이 조사의 결과를 분석한 결과 내용타당도(CVR)와 수렴도, 합의도를 모두 만족하는 것은 의구심과 경각심 두 가지 심리가 도출되었다. 최종적으로 이 내용을 적용하여, 모바일 어플리케이션의 도움을 받아 화재 대응 단계에서 피난하는 시나리오를 작성하였다. 본 연구를 통해서 화재발생시 재실자들의 피난률을 높이기 위해 이를 활용하는 방법을 적용할 수 있을 것이다.

우황에 대한 문헌적 고찰 (A Literary Study on Bezoar Bovis)

  • 박승규;박재석;백승일;권기록
    • 대한약침학회지
    • /
    • 제8권3호
    • /
    • pp.51-55
    • /
    • 2005
  • Objectives: Literary investigation of existing data was conducted to verify effects of Bezoar Bovis and its herbal acupuncture, and determine quality management through component analysis. Results: Following results were obtained through literary investigation. 1. Bezoar Bovis is dried cystic stone from a cattle. Its characteristics are cool, no toxicity, and bitter taste. Known actions are: quells heat and detoxifies Fire Poison, extinguishes internal movement of Liver Wind and stops convulsion, vaporizes phlegm, and opens orifice. It is mainly used for treating tremor, stroke, delirium, sore throat, oral furuncle, boil, and others. 2. Bezoar Bovis is effective for eliminating liver toxicity, protecting against brain damage, and has anti-microbial activities. 3. Bezoar Bovis is mixed with bear gall bladder and deer musk to be used as herbal acupuncture, and this mixture is effective is invigorating liver functions as well as treating arthritis, headache, and etc. 4. Principal components of Bezoar Bovis are bilirubin-type pigments and cholic acids. The amount of bilirubin can be used as a standard to determine the quality of Bezoar Bovis.

스프링클러헤드 감열부의 열적 특성에 관한 연구 (An Investigation on the Thermal Characteristics of Heat-Responsive Element of Sprinkler Head)

  • 유우준;문효준;염문천;유홍선
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.79-84
    • /
    • 2012
  • 본 연구에서는 국내외 스프링클러헤드 감도시험 기준에 적용하고 있는 반응시간지수(RTI, Response Time Index)를 사용하여 대류항과 전도항 그리고 시간 변화량을 고려한 감열부의 열전달 현상을 해석적으로 분석하였다. 원형 실린더 형상을 갖는 감열부의 열적 특성을 분석하기 위해서 비제차 2차 편미분 형태의 에너지 방정식을 사용하여 감열부 표면의 온도가 일정하고 대칭(Symmetric)인 경계조건을 적용하여 시간 증가에 대한 감열부의 반지름 방향 온도분포를 구하였다. 그 결과 본 연구의 감열부 열적 특성에 관한 분석 기법은 스프링클러헤드의 감도시험 및 감열부의 설계를 위한 자료의 활용이 가능할 것으로 판단된다.

이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰 (The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol)

  • 하동명
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2012
  • 이소프로필 알코올의 안전한 취급을 위해 $25^{\circ}C$에서 폭발한계를 고찰하였고, 실험장치를 이용하여 하부인화점, 상부인화점, 연소점 그리고 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 공정의 안전을 위한 이소프로필 알코올의 폭발 하한계는 2.0 vol%이고, 상한계는 12.0 vol%로 문헌을 통해 판단되었다. 하부인화점은 밀폐계에서 $12{\sim}14^{\circ}C$와 개방식에서 $18{\sim}19^{\circ}C$이었고, 상부인화점은 $38^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 측정된 최소자연발화온도는 $463^{\circ}C$이었다.

고온을 받은 콘크리트의 공학적 특성 (The Engineering Properties of Concrete Exposed at High Temperature)

  • 권영진;김용로;장재봉;김무한
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.31-36
    • /
    • 2004
  • 본 연구는 잔골재 및 혼화재 종류, W/C에 따른 콘크리트의 폭열성상 및 압축강도 초음파속도 등의 공학적 특성을 검토함으로서 폭열 방지 및 화재 피해를 입은 콘크리트 구조물의 재사용과 보수보강, 안전도평가 등에 기초적인 자료를 제시하고자 한다. 폭열성상을 살펴보면, 잔골재에 따라서는 바다모래를 사용한 경우 폭열이 발생하지 않았거나 약간의 폭열이 나타나는 정도이나 재생잔골재나 부순모래를 사용한 경우에는 폭열이 심하게 나타났다. 또한 혼화재 종류에 따라서는 대체로 유사한 폭열성상을 나타내었다. 한편, W/C 30.5%의 고강도 영역에서는 대부분 폭열하였으나 W/C 55%의 보통강도 영역에서는 대부분 폭열하지 않았다. 잔존 압축강도는 W/C 55%의 경우 평균 45%로 나타났으며, W/C 30.5%의 경우에는 평균 64%로 나타났다. 초음파속도는 잔골재 종류 및 W/C, 가열시간에 따라 다르게 나타났으며, 가열 후 3개월이 가열 후 1개월보다 약 1.3∼8.4%의 초음파속도 회복을 보였다.

재래시장 전기화재 감소를 위한 전기안전감시시스템 개발 연구 (Development of Electric safety monitoring system for reducing the electrical fire at traditional market)

  • 김기현;이상익;배석명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.259-262
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of traditional market developed the electric safety monitoring system which is suitable in traditional market. With for this did the actual condition investigation about electrical equipment of traditional market and we constructed Test-bed for testing reliability of electric safety monitoring system. Also experiment led in Test-bed and confirmed a stability. This paper following will be used with the data for the reliability security of the electric safe system operation which follows in the traditional market actual proof equipment construction which will be advanced.

  • PDF

섬유보강 고강도 콘크리트의 내구성능 향상에 관한 검토 (Investigation on Improve Durability of Fiber-Reinforced High-Strength concrete)

  • 이혜진;하정수;김규진;이영도;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.93-95
    • /
    • 2013
  • Recently, with the increase in the construction of ultra-high buildings and long-span structures, there is great demand for high-strength concrete which can reduce the structural weight and thickness of member sections. While developing high-strength concrete to meet performance requirements, certain issues at the design stage must also be considered. The issues include diseconomy from a great amount of per-unit cement, spalling failure by fire at ultra-high building, autogenous shrinkage caused by increased hydration activity of binder from use of a superplasticizer. Therefore, the purpose of this study is examined the strain characteristics of Fiber-reinforced-high-strength concrete(FRHSC), which differ from those of general concrete owing to autogenous shrinkage. Based on the experimental data, we proposed an autogenous shrinkage prediction model.

  • PDF