Fast and Efficient Method for Fire Detection Using Image Processing

  • Celik, Turgay
    • ETRI Journal
    • /
    • v.32 no.6
    • /
    • pp.881-890
    • /
    • 2010
  • Conventional fire detection systems use physical sensors to detect fire. Chemical properties of particles in the air are acquired by sensors and are used by conventional fire detection systems to raise an alarm. However, this can also cause false alarms; for example, a person smoking in a room may trigger a typical fire alarm system. In order to manage false alarms of conventional fire detection systems, a computer vision-based fire detection algorithm is proposed in this paper. The proposed fire detection algorithm consists of two main parts: fire color modeling and motion detection. The algorithm can be used in parallel with conventional fire detection systems to reduce false alarms. It can also be deployed as a stand-alone system to detect fire by using video frames acquired through a video acquisition device. A novel fire color model is developed in CIE $L^*a^*b^*$ color space to identify fire pixels. The proposed fire color model is tested with ten diverse video sequences including different types of fire. The experimental results are quite encouraging in terms of correctly classifying fire pixels according to color information only. The overall fire detection system's performance is tested over a benchmark fire video database, and its performance is compared with the state-of-the-art fire detection method.

A Design of Communication Protocol for Fire Detection by Using MANGO ZDK Development Tool (MANGO ZDK 개발툴을 이용한 화재감지용 통신 프로토콜 개발)

  • Yun, Dong-Yol;Joo, Young-Hoon;Kim, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.426-429
    • /
    • 2007
  • When a fire happens in builds or apartments, peoples are tend to be caught in dangerous situations owing to the failure of searching escape route to the outside. In this work, an efficient fire detection and alarm system which makes it possible for the escapers to take adequate actions is proposed. The proposed system consists of two parts. One is fire detection modules which are located at each compartments in a building. The other is fire warning modules equipped with portable flashes having ability of visual/voice warning. Fire detection information is transmitted between each modules wirelessly. In this work, an efficient communication protocol for sensor network-based fire detection system is proposed and its feasibility is verified by practical experiments using MANGO ZDK Development tools

  • PDF

Fire Detection Using Multi-Channel Information and Gray Level Co-occurrence Matrix Image Features

  • Jun, Jae-Hyun;Kim, Min-Jun;Jang, Yong-Suk;Kim, Sung-Ho
    • Journal of Information Processing Systems
    • /
    • v.13 no.3
    • /
    • pp.590-598
    • /
    • 2017
  • Recently, there has been an increase in the number of hazardous events, such as fire accidents. Monitoring systems that rely on human resources depend on people; hence, the performance of the system can be degraded when human operators are fatigued or tensed. It is easy to use fire alarm boxes; however, these are frequently activated by external factors such as temperature and humidity. We propose an approach to fire detection using an image processing technique. In this paper, we propose a fire detection method using multichannel information and gray level co-occurrence matrix (GLCM) image features. Multi-channels consist of RGB, YCbCr, and HSV color spaces. The flame color and smoke texture information are used to detect the flames and smoke, respectively. The experimental results show that the proposed method performs better than the previous method in terms of accuracy of fire detection.

A Study on the Early Response System Subway Cabin Arson Fire (지하철 차량 방화사고 초기대응에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Si-Gon
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.21-30
    • /
    • 2006
  • Since Daegu subway arson fire disaster in 2003, there have been several copycat crimes such as at Seoul Metro line number seven and Hongkong Chuiwan line cases. Oil and gas were used for fire propagation in most cases as in Daegu case and such fire could be expanded to a whole subway cabin within several minutes. The fire may eventually cause the whole subway system stop. Fire damage can be minimized when fire occurrence and diffusion are blocked by stages or isolated rapidly. This study suggests an effective early response system that separates passengers from fire and a real-time fire extinguishment program by stages. Based on the subway arson case studies, the early response scenario has been structured by three stages, i.e., confirmation of fire and damage, early fire extinguishment, and information dissemination and passengers evacuation.

A Study on the Evaluation Method of the Building Safety Performance and the during Building Fires with Computer Prediction of Occupants′ Egress Behavior Simulation (컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가 방법에 관한 연구(I))

  • 최원령;이경회
    • Fire Science and Engineering
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1989
  • It has been recognized that the escape facility planning is very important for effective evacuation of accupants on fire event. The ultimate goal of the escape facility planning is to evacuate occupants rapidly from building fires to the safe areas. In fire event, occupants usually gather, utilize and finally act upon information about state transient of building fire system, which is consisted of components of fire, building and accupant during the ralatively short period of the fire event. That is, occupants' egress behavior is largely dependent upon building fire system. Therefore, comprehensive study for the relationship between building fire system and occupants' egress behavior is needed. This study aims to suggest the pre -occupancy evaluation method of the life safety performance for the architectural design based on prediction of occupants' egress behavior during building fires with computer simulation.

  • PDF

The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory (화학공장의 소방안전을 위한 원격감시 제어시스템 개발)

  • Kim, Hyung-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

A Study on the Emergency Response System by Five Sense in the Subway Fire (오감인지를 통한 지하철 화재 비상대응시스템에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2008
  • In the subway fire case, it is important that judge accuracy subway fire type and on the initial response minimize accident damage. But when the subway fire accident occurring, if it have know impossible that accuracy subway fire type to judge at once though witnessing driver or emergency response staff. This study suggests type of five senses that using information of five sense take to the subway fire accident information which analyses five senses as occurring subway fire accident. Also it is proposed that emergency response system though fire scenario by using Activity-Action Diagram(AAD).

A Study on the Multiple Disaster Administration's Problem and Improvement (대형 재해관리의 문제점과 개선방안)

  • Kim, Hak-Soo;Koh, Jae-Moon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.7 no.1
    • /
    • pp.179-198
    • /
    • 2003
  • If see disaster administration system of our country, start in terms of is coping by countermeasure after four immediately after disaster occurrence many problems blessing with a sons by tribe and so on of link nature between formation, disaster administration complete charge utensil's absence, disaster charge manpower and budget be indicated and join. If examine improvement way accordingly, is as following ; Necessity of synthetic disaster administration system, Fire fighting formation's independence guarantee, Integration of fire fighting connection similarity business, Disaster administration's permanent establishment complete charge utensil's necessity, Disaster administration midautumn complete charge utensil at a metropolitan autonomous fire fighting system reorganization, Role division of labor between center and local government, Disaster administration professional human strength positivity, Disaster administration information system construction practical use, Equipment and improvement of budget state, Education public information for safety culture consciousness fixing, Internationalization of fire fighting business, globalization propulsion, Structure, member of rescue confrontation system and efficiency. Fire fighting environment is changing greatly, and fire fighting must become center to correspond to do confrontation that do one thing troble when produce disaster.

  • PDF

Establishment of Fire-Safety System that combines BIM technology for fire safety with drones and IT convergence technologies (화재안전을 위한 BIM기술과 드론 및 IT융복합 기술을 접목시킨 소방안전시스템 구축)

  • Kim, Dae-Geon;Lee, Gi-Hwi;Hong, Il-Hyeok;Kim, Min-Sung;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.175-176
    • /
    • 2018
  • While damage caused by fire increases, awareness of fire is still low. Morever, Small fires often spread into big fires as they fail to keep the golden time due to the delay in initial response. In particular, the initial response is more important in areas where many unauthorized buildings are called " Panjachon " as firefighting facilities are insufficient compared to other residential facilities. Therefore, we will combine BIM technology, drones and IT convergence technologies to develop a firefighting safety information system that can speed up initial response and help combat fires.

  • PDF

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.