• Title/Summary/Keyword: Fire frequency

Search Result 425, Processing Time 0.028 seconds

Analysis of Medicinal Ingredients that Compose Liu Hejian's Formulae (류하간(劉河間)의 처방 구성 약재에 대한 연구)

  • Jeong, Heon-Young;Keum, Kyung-Soo;Lee, Jae-Seon;Kae, Eun-Kyung;Sa, Hee-Su;Jeon, Hak-Su;Ko, Geum-Young;Lee, Jun-Geun;Hong, Seong-Cheon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.373-381
    • /
    • 2011
  • Liu Hejian maintained that the six types of energy can become fire and focused on the treatment of fire and heat symptoms along with the prescriptions of cryotherapy, believing that a vast majority of disease are due to fire. In this study, we investigated the characteristics of Hejian's formulae by classifying medicinal ingredients in consideration of medicinal properties and efficacy in order to examine how many cold and hot medicinal ingredients are included in the formulae of Hejian. We analysis 848 formulae among 1,055 formulae in total, excluding 207 redundant ones, which includes 366 Sunmyunglon formulae, 223 Bomyeongjip formulae, 8 Samsolon formulae, 61 Sanghanjigkyeok formulae, 68 Sanghanpyobon formulae, 22 Sanghansimyo formulae, 103 Hwalbeopgiyo formulae, 186 Bodongbiyo formulae, and 18 Gagamyoungbisippalbang formulae. In the analysis of the frequency of using each medicinal herb after classifying medicinal ingredients of Hejian's formulae by medicinal properties, we found that cold medicinal ingredients accounted for 40%, the biggest share in the formulae, and hot medicinal ingredients accounted for around 45%, which indicates that Hejian's formulae consist of both elimination and reinforcement and cold and heat, rather than cold medicinal ingredients only. As a comparison of the frequency of using each medicinal ingredients for the formulae by efficacy, we found that clear heat medicinal ingredients, totify qi and replenish blood medicinal herbs, and activate blood medicinal ingredients were most frequently used.

A study on the extraction of risk factor and its application for senile dementia patient at home based on accidental cases (사고사례를 통한 재가치매환자의 위험요소 추출 및 그 활용에 관한 연구)

  • Lee, Hang-Woon;Eom, Jin-Sup;Choi, Mi-Hyun;Lee, Soo-Jeong;Choi, Jin-Seung;Moon, Seok-Woo;Tack, Gye-Rae;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.12 no.1
    • /
    • pp.11-18
    • /
    • 2009
  • The purpose of this study was, first, to extract the risk factor by investigating several cases of accident of senile dementia patient at home, and second, based on these results to provide basic information for the determination of monitoring factor for the care of senile dementia patient. Basic and behavioral characteristics, Short form of Samsung Dementia Questionnaire (S-SDQ), Activities of Daily Living (ADL), and cases of accident were investigated with 55 senile dementia patient at home (16 male, 39 female). Based on these questionnaires, risk factors were extracted and frequency, cooccurrence frequency, and occurring place of risk factors, presence or not, region, and degree of injury were investigated. Frequency between risk factors and behavioral characteristics, ADL, and S-SDQ was analyzed by crosstabulation frequency analysis. Results showed that 12 risk factors were extracted, and the frequency of 'going out' was the highest, and risk factors for injury were 'tumble', 'bump', 'slip', and 'fall'. Cooccurrence frequency analysis showed that the occurrence of 'fall', 'going out', 'fire of gas', and 'violence' with other factors was relatively higher than others. The occurring place of risk factor was the highest in home neighborhood, and the region of injury in knee, and the degree of injury with bruise. Crosstabulation frequency analysis showed that factors which had difference in frequency of risk factor were behavioral disorder, disorder of daily living and ADL. Factor which had difference in frequency due to the degree of behavioral disorder and disorder of daily living was 'going out', and factors which had difference in frequency due to the degree of ADL were 'slip' and 'fire of gas'.

  • PDF

Posttraumatic Stress by Work in Firefighters (소방공무원의 직무별 외상 후 스트레스)

  • Baek, Mi-Lye
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.59-65
    • /
    • 2009
  • To investigate a posttraumatic stress, social support and work burden and to identify high risk group and related factors which were exerted influence on posttraumatic stress of firefighters. Data were gathered from total 264 firefighters consisting of 85 fire distinguishers & rescue workers, 96 emergency medical personnel and 83 in ambulance & fire truck drivers in C province and were analyzed 22 items by IES-R, 20 work burden items by Choi(2000), 8 social support items by Oh(2006) using SPSSWIN 14.0 program. Posttraumatic stress of general characteristics by work was showed significant difference in age, marriage status, education, position, office duration, mobilization frequency and experience of traumatic events. Posttraumatic stress were showed significant difference in 3 groups and fire distinguishers & rescue workers is the highest group. Posttraumatic stress was correlated with work burden(r=.317, p<0.01) for fire distinguishers & rescue workers, social support(r=-.331, p<0.01) and work burden(r=.522 p<0.001) for emergency medical personnel and work burden(r=.454, p<0.01) for ambulance & fire truck drivers. The high risk groups are fire distinguishers & rescue workers(60%), emergency medical personnel(55.2%)and ambulance & fire truck drivers(45.8%). Related factors are the experience seeing victim's danger for fire distinguishers & rescue workers(odds ratio=1.216, 95% confidence interval:1.068-1.383), and are work burden(odds ratio=1.100, 95% confidence interval:1.043-1.159) and office duration(odds ratio=1.010, 95% confidence interval 1.001-1.018) for emergency medical personnel, and are the experience seeing victim's danger(odds ratio=1.178, 95% confidence interval:1.010-1.373), age(odds ratio=1.129, 95%confidence interval:1.020-1.249), work burden(odds ratio=1.103, 95% confidence interval:1.034-1.177) for ambulance & fire truck drivers.

Numerical Analysis of Three Dimensional Supersonic Flow around Cavities

  • Woo Chel-Hun;Kim Jae-Soo;Kim Jong-Rok
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.05a
    • /
    • pp.311-314
    • /
    • 2006
  • The supersonic flow around tandem cavities was investigated by three- dimensional numerical simulations using the Reynolds-Averaged Navier-Stokes(RANS) equation with the $\kappa-\omega$ thrbulence model. The flow around a cavity is characterized as unsteady flow because of the formation and dissipation of vortices due to the interaction between the freestream shear layer and cavity internal flow, the generation of shock and expansion waves, and the acoustic effect transmitted from wake flow to upstream. The upwind TVD scheme based on the flux vector split using van Leer's limiter was used as the numerical method. Numerical calculations were performed by the parallel processing with time discretizations carried out by the 4th-order Runge-Kutta method. The aspect ratio of cavities are 3 for the first cavity and 1 for the second cavity. The ratio of cavity interval to depth is 1. The ratio of cavity width to depth is 1 in the case of three dimensional flow. The Mach number and the Reynolds number were 1.5 and $4.5{\times}10^5$, respectively. The characteristics of the dominant frequency between two-dimensional and three-dimensional flows were compared, and the characteristics of the second cavity flow due to the fire cavity flow cavity flow was analyzed. Both two dimensional and three dimensional flow oscillations were in the 'shear layer mode', which is based on the feedback mechanism of Rossiter's formula. However, three dimensional flow was much less turbulent than two dimensional flow, depending on whether it could inflow and outflow laterally. The dominant frequencies of the two dimensional flow and three dimensional flows coincided with Rossiter's 2nd mode frequency. The another dominant frequency of the three dimensional flow corresponded to Rossiter's 1st mode frequency.

  • PDF

An Approach to Risk Assessment of City Gas Pipeline (도시가스 배관의 위험평가 방법론 제시)

  • Park Kyo-Shik;Lee Jin-Han;Jo Young-Do;Park Jin-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.33-40
    • /
    • 2003
  • In this work, a novel approach was introduced to assess cost of loss resulting from risk as well as to help deciding inspection period through quantifying risk. In order to quantifying risk of city gas pipeline, frequency and consequence analysis were required. The main causes of city gas accident were analyzed to be digging, external corrosion, ground movement, and equipment failure. Tools to evaluate frequency of each cause was also suggested. Among city gas accidents, fire damage is the dominant one and mainly discussed; fatality, burning injury, and damage to building were estimated using the consequence model suggested. By combining frequency and consequence analysis, evaluating cost of risk management together with calculating example. This work could be applicable for city gas companies to plan how to manage risk most effectively.

  • PDF

Risk Analysis of Ammonia Leak in the Refrigeration Manufacturing Facilities (냉동제조 시설의 암모니아 누출사고 위험 분석)

  • Kang, Su-Jin;Lee, Ik-Mo;Moon, Jin-Young;Chon, Young-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • Recently, ammonia leak occurred frequently in the domestic refrigeration manufacturing facilities. Ammonia caused great damage to the environment and human health in the event of an accident as combustible gases and toxic gases. After considering the types of ammonia accidents of domestic refrigeration manufacturing facilities and selected accident scenarios and to analyze the risk analysis through Impact range estimates and frequency analysis and there was a need to establish measures to minimize accident damage. In this study, depending on the method of analysis quantitative risk assessment we analyzed the risk of the receiver tank of ammonia system. Scenario analysis conditions were set according to the 'Technical guidelines for the selection of accident scenario' under the chemicals control act and 'Guidelines for chemical process quantitative risk analysis' of center for chemical process safety. The risk estimates were utilized for consequence analysis and frequency analysis by SAFETI program of DNV, event tree analysis methodology and part count methodology. The individual risk of ammonia system was derived as 7.71E-04 / yr, social risk were derived as 1.17E-03 / yr. The derived risk was confirmed to apply as low as reasonably practicable of the national fire protection association and through risk calculation, it can be used as a way to minimize accidents ammonia leakage accident damage.

Analysis of Contents of Website Information about CPR and Automated External Defibrillator (심폐소생술(CPR) 및 자동제세동기(AED)에 대한 웹사이트 내용성 분석)

  • Gang, Bo-Ra;Yang, Hyun-Mo;Lee, In-Soo
    • The Korean Journal of Health Service Management
    • /
    • v.7 no.3
    • /
    • pp.29-44
    • /
    • 2013
  • The purpose of this study is to give the users, who wants to know the information about CPR and AED on the Internet, more accurate information which is analyzed and considered with the factors to improve the contents of them. The source of the instrument for this study is from the contents of twenty four websites which is able to join in and searched by the Web Search Engine with four keywords: 'Cardiopulmonary Resuscitation', 'CPR', 'Automated External Defibrillator', and 'AED'. According to the results of the study, frequency questions of more than 50% among 53 questions on whether to suggest were investigated as 22 questions from content analysis results of the websites, and it showed that the highest frequency, which were examined to that chest compressions and respiratory rate; 79.2%. The correctness of the contents of the all websites of the study is as low as 36.00 point full marks at 100 points.

Effect of Earthquake characteristics on seismic progressive collapse potential in steel moment resisting frame

  • Tavakoli, Hamid R.;Hasani, Amir H.
    • Earthquakes and Structures
    • /
    • v.12 no.5
    • /
    • pp.529-541
    • /
    • 2017
  • According to the definition, progressive collapse could occur due to the initial partial failure of the structural members which by spreading to the adjacent members, could result in partial or overall collapse of the structure. Up to now, most researchers have investigated the progressive collapse due to explosion, fire or impact loads. But new research has shown that the seismic load could also be a factor for initiation of the progressive collapse. In this research, the progressive collapse capacity for the 5 and 15-story steel special moment resisting frames using push-down nonlinear static analysis, and nonlinear dynamic analysis under the gravity loads specified in the GSA Guidelines, were studied. After identifying the critical members, in order to investigate the seismic progressive collapse, the 5-story steel special moment resisting frame was analyzed by the nonlinear time history analysis under the effect of earthquakes with different characteristics. In order to account for the initial damage, one of the critical columns was weakened at the initiation of the earthquake or its Peak Ground Acceleration (PGA). The results of progressive collapse analyses showed that the potential of progressive collapse is considerably dependent upon location of the removed column and the number of stories, also the results of seismic progressive collapse showed that the dynamic response of column removal under the seismic load is completely dependent on earthquake characteristics like Arias intensity, PGA and earthquake frequency contents.

The Ion Generation Characteristics of Charge Neutralizer Applied a Pulse Voltage (펄스전압을 적용한 전하중화장치의 이온발생 특성)

  • Moon, Jae-Duk;Chung, Suk-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.140-146
    • /
    • 1998
  • Methods and systems to remove static electricity are requested necessarily because the static electricity causes a flammable gas explosion, a fire, reduction of production rate in manufacturing VLSI semiconductor device and so on. In this paper, abrasion and dust contaminant of needle electrode are studied experimentally. And, frequencies and pulse durations of a high frequency pulse source were controlled effectively to minimize the abrasion of needle electrode and control generated numbers of ions. As a result, it is verified experimentally that the ion generation of charge neutralizer increases by using a high frequency pulse source.

  • PDF

A Development on Universal RF based Module for Wireless Network (계측 시스템의 무선통신을 위한 RF모듈 개발)

  • Park, Suk-Hyun;Shim, Woo-Hyuk;Seo, Young-Jo;Kim, Beung-Jin;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3064-3066
    • /
    • 1999
  • The existing equipment with wire communication can expect the stability of data transmission. However, according to increasing a number of DTE (Data Terminal Equipment), wiring work becomes a heavy burden. Restriction to application about portable DTE and the lack of flexibility are another drawback of wire communication. This paper presents the design and implementation of a RF (Radio Frequency) based wireless communication system. The RF based module is designed to the multi communication between DTEs. The RF based module consists of RF circuit and microprocessor. The main properties of RF circuit are maximum 5Kbps transmission rate, maximum 90m transmission distance and 433MHz frequency band. The microprocessor rearrange the data into AHDLC(Advanced High level Data Link Control) format and then instructs RF circuits to transmit/receive the data. The RF module have a wide application field such as fire/security alarm, remote control/measurement etc..

  • PDF