• Title/Summary/Keyword: Fire frequency

Search Result 425, Processing Time 0.024 seconds

A Study on the Impacting Factors Influencing on the Volunteer Firefighter's Satisfaction in Sejong City Upon their Activities as a Volunteer Firefighter (세종특별자치시 의용소방대원의 활동 만족도에 미치는 영향 요인 연구)

  • Kim, Seon Woong;Lee, Wonjoo;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.96-103
    • /
    • 2016
  • The purpose of this paper is to study effects of participation motivations, relationships, and compensation on a satisfaction in activity of volunteer firefighter. For this purpose, we surveyed 106 volunteer firefighter worked in Sejong city. The survey data was analyzed the reliability in questionnaire design by SPSS 20.0 win program. Also, the interrelationship of each factors were confirmed by analysis of frequency, percentage and regression analysis. Furthermore, the regression analysis was performed in order to investigate effects of motivations, interpersonal relationships, and compensation on a satisfaction in activity of volunteer firefighter. A factor of motivations, interpersonal relationships, and compensation was found to be a positive influence on a satisfaction in activity of volunteer firefighter under significance probability of < 0.05. The overall satisfaction was influenced in order of motivations, compensation, interpersonal relationships. This paper is expected to serve as a basis for the efficient operation of the Korean Volunteer Fire Department.

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

A Study on the Propagation Characteristics of Fire Alarm Sound in Buildings (화재비상경보음의 건물 내 전달특성에 관한 연구)

  • Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.153-160
    • /
    • 2009
  • This study aims to review the propagation characteristics of fire alarm sound in building through computer simulation. In order to achieve this goal, the sound power level of existing three different emergency alarms were measured in an anechoic chamber. Sound power level of alarm bell was 98.6dB and electronic-siren speaker was 95.7dB, and electronic-siren phon was 101.8dB at the voltage of DC 24V in the condition of anechoic chamber. As the results of acoustic simulation, it was shown that sound levels at the corridor of the building were relatively high and even. But, there were large difference in sound level at all the frequency bands between corridor and lecture rooms. This mean that alarm sound couldn't be recognized sometimes in lecture rooms. Through the computer simulation, the propagation characteristics of fire alarm sound could be forecasted and compared due to plans of buildings.

Sensitivity Analysis on Ecological Factors Affecting Forest Fire Spreading: Simulation Study (산불확산에 영향을 미치는 생태학적 요소들간의 민감도 분석: 시뮬레이션 연구)

  • Song, Hark-Soo;Lee, Sang-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.3
    • /
    • pp.178-185
    • /
    • 2013
  • Forest fires are expected to increase in severity and frequency under global climate change and thus better understanding of fire dynamics is critical for mitigation and adaptation. Researchers with different background, such as ecologists, physicists, and mathematical biologists, have developed various simulation models to reproduce forest fire spread dynamics. However, these models have limitations in the fire spreading because of the complicated factors such as fuel types, wind, and moisture. In this study, we suggested a simple model considering the wind effect and two different fuel types. The two fuels correspond to susceptible tree and resistant tree with different probabilities of transferring fire. The trees were randomly distributed in simulation space with a density ranging from 0.0 (low) to 1.0 (high). The susceptible tree had higher value of the probability than the resistant tree. Based on the number of burnt trees, we then carried out the sensitivity analysis to quantify how the forest fire patterns are affected by wind and tree density. The statistical analysis showed that the total tree density had greatest effect on the forest fire spreading and wind had the next greatest effect. The density of the susceptible tree was relatively lower factor affecting the forest fire. We believe that our model can be a useful tool to explore forest fire spreading patterns.

Developing Forest Fire Status Information Management System using Web GIS Technology (웹 지리정보시스템 기술을 이용한 산불 현황정보 관리시스템 개발)

  • Jo, Myung-Hee;Kim, Joon-Bum;Kim, Hyun-Sik;Jo, Yun-Won
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.5 no.4
    • /
    • pp.93-105
    • /
    • 2002
  • In this paper forest fire status information management system was developed under web environment using web GIS(geographic information system) technology. Though this system, general users can easily retrieval domestic forest fire status information and obtain that in visual way such as maps, graphs, and texts if they have only certain web browsers. Moreover, officials, who have system access authority, can easily control and manage all domestic forest fire status information through input interface, retrieval interface, and out interface of the system. This system can be considered as the first domestic system to manage forest fire status data and service them in visual through user friendly interfaces on web. In order to implement this system, IIS 5.0 of Microsoft is used as web server and Oracle 8i and ASP(active server page) are used for database construction and dynamic web page operation, respectively. Also, ArcGIS IMS(internet map server) of ESRI is used to serve maps by using Java and HTML as system development languages. Not only the domestic tendency of forest fire but also the forest fire status information of certain area and time such as the frequency and the loss can be presented through distribution maps, graphs and tables. Therefore, this system is supposed to play as a important role when the policy relate to domestic forest fire is established. In addition, the self consciousness of people against forest fire can be inspired and the foundation of scientific and systemic forest fire services can be obtained through this system in the future.

  • PDF

Serviceability Evaluation of Slim Composite Floor System (슬림 합성보 바닥시스템의 사용성 평가)

  • Eun, Hee-Chang
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.63-70
    • /
    • 2008
  • Slim floor construction is becoming used throughout many countries. It combines the advantages of flat slab construction with significant inherent resistance to fire. The slim floor system with web openings leads to the reduction of its self-weight. Although the system has enough strength and stiffness, it is necessary to evaluate and improve the effects of dynamic vibration to be able to annoy the residents. Thus, this study evaluates the serviceability of vibration effects based on the dynamic test of five slim composite beams. Based on the experimental results, the initial stiffness and natural frequency of all specimens exhibit the similar trend regardless of the opening and the shape of cross section. The decrease in natural frequency is deeply related to the reduction in the stiffness of specimens and thus, it can be concluded that the damage of slim composite floor can be detected by the measurement of natural frequency instead of the load-carrying capacity and the stiffness.

A study on the evaluation of fire safety according to the ventilation mode in a train fire at the subway platform (지하철 승강장에서 열차 화재시 제연모드에 따른 화재 안전성 평가 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.293-310
    • /
    • 2020
  • The purpose of this study is to present the most effective smoke exhaust mode by comparing the quantitatively evaluated risks according to the smoke exhaust mode when a train fire occurs in a subway platform. Therefore, applying the typical subway platform as a model, train fire scenarios are developed with the evacuation start time and location of the fire train for each exhaust mode. The fire accident rates (F) are calculated and the number of fatalities (N) was quantitatively estimated by fire analysis and evacuation analysis for each scenario. In addition, the F/N curve compared with the social risk assessment criteria and the following conclusions were obtained. In the event of a train fire at the subway station platform, the evacuation must start up within 600 s in maximum to ensure the evacuees' safety. To secure evacuation safety, it is advantageous to operate the HVAC system of the platform in the air-supply mode at station without TVF. Comparing the F/N curve for each exhaust mode with the social risk criteria, it turned out that the risk significantly exceeds the social risk criteria in case of no mechanical ventilation. As a result, this paper shows that the ventilation mode in which TVF are exhausted and HVAC system is operated in the pressurized mode are the most effective smoke exhaust mode for ensuring evacuation safety.

Forest Fire Area Extraction Method Using VIIRS (VIIRS를 활용한 산불 피해 범위 추출 방법 연구)

  • Chae, Hanseong;Ahn, Jaeseong;Choi, Jinmu
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.669-683
    • /
    • 2022
  • The frequency and damage of forest fires have tended to increase over the past 20 years. In order to effectively respond to forest fires, information on forest fire damage should be well managed. However, information on the extent of forest fire damage is not well managed. This study attempted to present a method that extracting information on the area of forest fire in real time and quasi-real-time using visible infrared imaging radiometer suite (VIIRS) images. VIIRS data observing the Korean Peninsula were obtained and visualized at the time of the East Coast forest fire in March 2022. VIIRS images were classified without supervision using iterative self-organizing data analysis (ISODATA) algorithm. The results were reclassified using the relationship between the burned area and the location of the flame to extract the extent of forest fire. The final results were compared with verification and comparison data. As a result of the comparison, in the case of large forest fires, it was found that classifying and extracting VIIRS images was more accurate than estimating them through forest fire occurrence data. This method can be used to create spatial data for forest fire management. Furthermore, if this research method is automated, it is expected that daily forest fire damage monitoring based on VIIRS will be possible.

Electric Fire Prediction by Detection of Discharge Signal (방전신호 검출에 의한 전기화재 예측)

  • 길경석;송재용;권장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.413-419
    • /
    • 2004
  • This paper describes a technique that can predict electric fires by detection of discharge voltage signals caused by the use of electric facilities. In the experiment, various discharge modes, a flashover or a surface discharge through insulation paper and a line to line short, were simulated to acquire electrical information for predicting electrical fire as discharge modes. From the experimental results, it is hewn that electorial discharges which are ranked as majority causes of electric fires generate characterized signals distinguished from power frequency. Finally. We designed a prototype discharge detector based on the experimental results, and the detector is applied to a power lines. This study showed that the prediction of electric fires is possible by monitoring discharge voltage signals in electric power lines.

Response Characteristic of HVDC System According to Frequency Sensing Methods (주파수 측정방법에 따른 HVDC시스뎀의 응답특성)

  • Kim C,K;Yang B.M;Park J.G.;Jeong G.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.299-303
    • /
    • 2003
  • This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system areto fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is use a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC Program and experimental test.

  • PDF