• Title/Summary/Keyword: Fire evacuation

Search Result 695, Processing Time 0.03 seconds

A Study on the Character and Walking Velocity of Crowd Going up Stairs (계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-77
    • /
    • 2011
  • The effort of transferring some parts of urban functions to the underground space is growing trend among modem cities because of the limit of horizontal land use, the rise of land value, the diversification of human desire, etc. Thus, the basement of building and the subway station have deepened. It calls our attention to safety about evacuation from the underground space to the ground. Until now, the study about crowding walk in stairs has been progressed, focusing on the crowding walk that is going down the stairs, and there is no study about crowding walk that is going up the stairs. This study measured walking pace by crowd density that is going up the stairs in the subway station stairs making one-way movement of crowd. The actual survey showed that the mathematical relation 'V=0.638-0.0949p' determines going up walking velocity at a gradient of $23^{\circ}$, and the mathematical relation will be 'V=0.597-0.1067p' at a gradient of $30^{\circ}$, when it is converted, based on the average walking velocity of crowd by the slope of the stairs which is recommended by Architectural Institute of Japan.

Case Study of the Longest Roadway Tunnel in Korea, Baehuryeong Tunnel (국내 최장대 양방향 도로터널 설계사례-배후령터널)

  • Lee Seon-Bok;Je Hae-Chan
    • Tunnel and Underground Space
    • /
    • v.15 no.6 s.59
    • /
    • pp.432-440
    • /
    • 2005
  • Baehuryeong tunnel connects Chuncheon with Hwacheon in Kangwon, Korea, This tunnel is a single tunnel with 5,057 m long and two bidirectional lanes which will be extended into low lanes in the future. The estimated construction period of Baehuryeong tunnel is approximately 55 months. This tunnel will become the longest bidirectional roadway tunnel in Korea. Compared to a twin tunnel, a bidirectional single tunnel has two major disadvantages with regard to the ventilation system and ease of escape during fire. For these reasons, a service tunnel and the transverse ventilation system are planned first time in Korea. In case of fire, the tunnel ventilation design aims to maintain a smoke free layer for passenger evacuation. The geology of Baehuryeong tunnel site is mainly composed of gneiss and granite. Baehuryeong fault is a mainly large scale fault which stands vertical and parallels with tunnel direction. The influenced zone of this fault is within 70 m. Baehuryeong tunnel was designed that it was separated with the distance of more than 100 m from Baehuryeong fault for its safety.

The Counterflow Speed and Density of a Fire fighter in Corridor (복도에서 소방관에 의한 카운터플로우 발생 시 밀도와 속도 측정)

  • Kim, Woon-Hyung;Kim, Heung-Youl;Joung, Woo-In;Kim, Jong-Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.76-83
    • /
    • 2019
  • Purpose: The purpose of this study is to present data of density and speed through the experiment of the counterflow by firefighter in corridor. Method: Experimental setup including a corridor in building was prepared for measuring data with 1.5m and 2m width. Normal flow and counterflow were created for each. Data were measured using camera and acquired by video image analysis. Results: The counterflow in corridor resulted in increasing average density of about $0.55P/m^2$ and decreasing average movement speed of about 0.61 m/s. These data measured during the time when the counterflow occurred. Conclusion: It was found that counterflow by firefighter in corridor momentary increasing the density and decreasing walking speed of evacuee. Further experiments of the counterflow effect in the total evacuation time are needed.

Correlation Analysis between BLE-based RSSI and SoC Internal or Local Temperature (BLE 기반 RSSI와 SoC 내부 또는 국부 온도의 상관관계)

  • Kim, Seong-Chang;Lee, Min-Jeong;Oh, Sung-Bhin;Kim, Jun-Su;Kim, Jin-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.89-91
    • /
    • 2022
  • Wireless sensor networks(WSN), which are mainly used for indoor positioning, rely on the accuracy of RSSI. This RSSI is sensitive to several factors that cause interference, and there are foreign studies showing that temperature has a large effect on RSSI in indoor/outdoor environment among several factors. The temperature of the indoor space is uneven due to heat sources or air cooling systems indoors, and temperature changes frequently occur at certain locations. In particular, in case of an indoor fire, the accurate positioning system is required to guide an evacuation route, but a high temperature is locally formed due to a fire around the receiver, so the RSSI value could be influenced. In this paper, the effect on RSSI is studied by analyzing the correlation between SoC internal/local temperature and RSSI.

  • PDF

Flow and smoke behavior of a longitudinal ventilation tunnel with various velocities using computational fluid dynamics (팬의 운전조건에 따른 종류식환기터널 내의 연기거동에 관한 전산유체역학연구)

  • Lee, J.H.;Kwon, Y.J.;Kim, D.E.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.1
    • /
    • pp.105-115
    • /
    • 2014
  • A numerical analysis on the smoke behavior and evacuee safety has been performed with computational fluid dynamics. The purpose of this study is to build computational processes for an evacuation and prevention of a fire disaster of a 3 km-length tunnel in Korea. To save computational cost, 1.5 km of the tunnel that can include a few cross-passing tunnels is considered. We are going to assess the fire safety in a road tunnel according to the smoke level, which consists of the smoke density and the height from the floor. The smoke density is obtained in detail from three-dimensional unsteady CFD analysis. To obtain proper temperature distributions on the tunnel wall, one-dimensional conduction equation is considered instead of an adiabatic wall boundary or a constant heat flux. The tunnel considered in this study equips the cross passing tunnels for evacuees every 250 m. The distance is critical in both safety and economy. The more cross passing tunnels, the more safe but the more expensive. Three different jet fan operations can be considered in this study; under- and over-critical velocities for normal traffic condition and 0-velocoty operation for the traffic congestion. The SE (smoke environment) level maps show a smoke environment and an evacuating behavior every moment.

A study on the Optimum Capacity of Citadel (선원대피처의 적정규모에 관한 연구)

  • Kim, Won-Ouk;Chae, Yang-Bum;Kim, Chang-Jae
    • Journal of Navigation and Port Research
    • /
    • v.36 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • Recently, vessel hijacking by pirates has been a big issue around the world. For example, the hostages of VLCC "SAMHO Dream" were released for a large sum of ransom. On January 20, 2011 "SAMHO Jewelry" succeeded releasing all of the 21 crews on the vessel by attacking the pirates in international waters for the first time since the founding of the Naval Force. Furthermore, the "HANJIN Tianjin" crews evacuated to the Citadel promptly and were rescued by the navy. As hijacking of Korean vessels by pirates is increasing, various safety measures must be implemented. As a matter of fact, the standard for ship's facilities has been partially revised and setting up an evacuation shelter on all vessels sailing dangerous zone has been reinforced. This research aims to discuss crew Citadel installation on vessels intended for long haul. In addition, it will look at measures against potential gas flow in the event of pirate armed attacks and fire outbreak onboard a vessel. It will also assess the optimal number of crew Citadels theoretically. Lastly, the optimal number of shelters in the event of fire outbreak will be discussed based on an FDS simulation.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

An Implementation of Congestion-based Server System for LBS Fire Evacuation Service (위치기반 화재대피 서비스를 위한 혼잡도 기반 서버시스템 구현)

  • Song, Dong-Hyuk;Min, Jin-Ki;Seo, Hyo-Seung;Lee, Joon-beom;Kim, Hyeon-Jung;Son, Bong-Ki;Lee, Jaeho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.452-454
    • /
    • 2016
  • 화재와 지진 등 재난 발생 시 인원이 많이 밀집되어 있는 건물 내에서는 혼란스러운 상황이 발생하는 것이 일반적이고 각 건물 내 사람들이 통솔하기도 어렵다. 이러한 문제를 해소하기 위해 본 논문에서는 상황에 따른 장치 간 전송하는 데이터를 나누어 데이터 전송에 효율성을 높이며 데이터베이스를 제안하여 데이터 간 관련성과 관리에 효율성을 높이고 사용자에게 직접 건물 내 상황을 알리고 안정적으로 대피를 할 수 있도록 도움을 주는 기술과 그에 필요한 Protocol을 제안한다.

Examination for Methodology of Design of Emergency Lightings by Using Space Syntax Theory (공간구문론을 이용한 지하공간 비상유도등의 효율적인 위치선정 방법론 검토)

  • Won, Seul-Ki;Kim, Young-Uk;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.1-9
    • /
    • 2006
  • The emergency lighting plan for underground space should be done with consideration of characteristics of the space. In terms of utilizing the Depthmap program from the Space Syntax theory, it is possible to analyze space quantitatively. Integration and intelligibility are major induces of this theory and we can use them as emergency lighting design parameters. For this study, human behaviors and survivor's evacuation routes in fire emergencies are analyzed through literature review. Based on those results, this study suggests the methodology of emergency lighting plan in underground space.

A basic study on improvement of Disasters Prevention System using space information from 3D CAD - focused on Multiple-use Facilities - (3D CAD 공간 정보를 활용한 방재 시스템 개선에 관한 기초 연구 - 다중이용시설물 중심으로 -)

  • Lee, Myoung-Hoon;Ahn, Byung-Ju;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.189-193
    • /
    • 2009
  • As large-scale buildings, skyscrapers, and multi-purpose buildings recently increase in numbers dramatically the internal space of such buildings becomes more and more large and complicated accordingly. The Multi-purpose buildings are increasing rapidly in number, and concerns over the evacuation process in case of fire emergency are also increasing. However, A controller who is responsible for visitor's safety makes a decision about measures for visitor safety in human based decision making process. Many potential accidents that are caused by human error lurk in results of the process. The accidents can be decreased by changing the decision making process from human-based into technology-based. Through this study, the way to improve current disasters prevention system is presented and it can also improve shelter inducement methods effectively. SICS(Spatial Information Control System) which is being studied in other research is used as the tool for improvement.

  • PDF