• Title/Summary/Keyword: Fire escape safety

Search Result 118, Processing Time 0.024 seconds

Evaluation of the Appropriateness of Smoke Control Conditions of Platform at the Subway Fire by using FDS (FDS를 이용한 지하철 객실 화재 시 승강장 제연조건의 적정성 평가)

  • Kim, Ki-Sung;Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.8-14
    • /
    • 2013
  • In the subway, various fires continue to take place across the world. In the Daegu subway accident in 2003, many people were damaged by shortened visibility range caused by toxic gas and smoke. This paper, assuming that a subway fire happens in the Mandeok Station of the subway system in Busan, analyzed different smoke-spreading situations depending on the ventilation situation at its platform (opening of the train doors, operation of ventilation facilities in the tunnel, and working of fire door), using FDS. The calculation proved that it would be more effective to secure evacuation route when the ventilation facilities of the tunnel are not operated, than when they are on. And, it was also found that the case where the doors of the platform to the escape route and only the platform-facing doors of the subway car on fire office are open would be more effective to ventilation than the case where all the doors are open. And, it was found to be important that the fire doors of the platform are working properly.

Radio Frequency Based Emergency Exit Node Technology

  • Choi, Youngwoo;Kim, Dong Kyoo;Kang, Do Wook;Choi, Wan Sik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.91-100
    • /
    • 2013
  • This paper introduces an indoor sensor fusion wireless communication device which provides the Location Based Service (LBS) using fire prevention facility. The proposed system can provide information in real time by optimizing the hardware of Wi-Fi technology. The proposed system can be applied to a fire prevention facility (i.e., emergency exit) and provide information such as escape way, emergency exit location, and accident alarm to smart phone users, dedicated terminal holders, or other related organizations including guardians, which makes them respond instantly with lifesaving, emergency mobilization, etc. Also, the proposed system can be used as a composite fire detection sensor node with additional fire and motion detect sensors.

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

CFD-based Fire Accident Impact Analysis in Clean Room for semiconductor PR Process (반도체 PR 공정의 클린룸내 CFD 기반 화재 사고 영향 분석)

  • Chun, Kwang-Su;Yi, Jinseok;Park, Myeongnam
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.35-44
    • /
    • 2021
  • The PR (Photo Resist) process in the semiconductor process is a process that uses a mixture of flammable substances. Due to the process equipment is installed in a clean room and when flammable substances leak, there is a high risk of suffocation, fire, and explosion. It is necessary to analyze the impact of accidents that may occur during operation and to evaluate whether the safety of workers can be guaranteed. In this study, the value of radiant heat and temperature change at the monitor point set up virtual inside the clean room was confirmed through CFD simulation of 10 leak and fire scenarios using the FLACS CFD - Fire Module. A fire that occurs inside a clean room transfers high radiant heat to the inter-story structure, but its scope is quite limited, and it is unlikely that it will collapse in a single fire accident. There was no scenario in which two stairs leading to the exit were exposed to high radiant heat at the same time due to a fire accident, therefore workers were able to escape in case of a fire. In addition, it was confirmed that the level of radiant heat and temperature rise rapidly decreased as they moved downstairs. According to the API 520 standard, workers exposed to 6.31 kW/m2 of radiant heat that workers can withstand for 30 seconds were confirmed that it was possible to sufficiently escape from the inside.

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.

Survey on a Research for Fire Safety in Space with the Understanding of Combustion Characteristics in Microgravity based on NASA's Space Research Program (NASA의 우주 연구 프로그램에 따른 미소 중력하에서의 연소 특성 및 화재 안전 연구 개괄)

  • Sohn, Chae-Hoon;Son, Young-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.65-72
    • /
    • 2007
  • Fire is one of important checkpoints in crewed exploration systems, where men inhabit in space. In space, astronaut can't escape from fire out of a spacecraft and not expect any help of fire fighters, either. Accordingly, the best way to stand against fire is to prevent it. But, when fire occurs in space, flame behaviors are quite different from those observed on earth because of micro- or zero-gravity in space. The present paper introduces major research results on flame behaviors under microgravity and fire prevention, detection, and suppression in crewed exploration spacecrafts and international space station based on NASA's FPDS research program.

A Study on the Smoke Venting Plan in the High-Rise Building Fires (고층건물 화재시 배연계획에 관한 연구)

  • 김우영
    • Fire Science and Engineering
    • /
    • v.3 no.1
    • /
    • pp.11-18
    • /
    • 1989
  • The suffering damage of persons and properties from fires has become large sized in modem society that buildings are rapidly higher, denser and more complex. Especially, in the building fires, it is recently the most important issue that the treatment of smoke which is the hardest hindrance in escape. Therefore, as effective exhaust matter of smoke or poisonous gas is connected directly, synthetic, fundamental fire prevention countermeasure must be achieved after mutual connections between architecture and mechanical system and requlations ars sufficiently examinated. From this studies, 1 show the structure computation data which can be applied to smoke venting plan and architectural design for safety after find necessity and point at issue of prevention plan of fires by examinating statistical data about cause and damage situation.

  • PDF

A Study on the Consciousness Investigation of Fire Protection and Safety Measures of Escape in Hotel Buildings (호텔건축물의 방화의식조사 및 피난안전대책에 관한 연구)

  • 안태용;이영재
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.233-241
    • /
    • 2001
  • 호텔 건축물은 현대적 기능요구에 따라 대규모화, 고급화, 복합용도화 될 것으로 예상된다. 또한 건물 이용자는 불특정 다수인으로 그 건물에 대한 정보가 부족하기 때문에 화재시 인명 피해가 우려된다, 그러므로 이러한 문제점을 극복하기 위하여 호텔 건축물에는 화재·피난안전상 유의하여야 할 사항에 대하여 체계적인 방화시설이 요구된다. 본 연구에서는 첫째, 호텔의 이용실적조사, 화재관련통계 화재사례조사, 방화의식조사를 하였으며, 둘째, 호텔 건축물의 건축계획적인 사항을 검토하였으며, 셋째, 방재시설에 관한 법규정을 분석한 후 제안하였다. 이 연구의 목적은 화재시 인간 및 재산의 보호와 그 피해를 최소화할 수 있는 호텔공간을 건축하는데 기초적인 자료를 제시하는 것이다.

  • PDF

A Study on Security Plans At Large-Scale International Event Halls: Focusing on Assessment of Escape Safety of K Stadium for The Incheon Asian Games (대규모 국제행사장의 경호경비계획에 관한 연구: 인천 아시안게임 K경기장의 피난안전성 평가를 중심으로)

  • Park, Nam-Kwun;Lee, Young-Ju;Yoon, Myong-O
    • Korean Security Journal
    • /
    • no.30
    • /
    • pp.7-32
    • /
    • 2012
  • Korea faces The 2014 Incheon Asian Games and 2018 Pyungchang Winter Olympics. It is imperative to hold a safe event for the economic benefits, enhancing Korea's image, social integration, national harmony and unity in order to be evaluated as a successful international event. Furthermore, since the international event tends to draw many spectators, the host country must be ready to accommodate a large number of injured people in the event of an accident or terror attack. As stadiums for international events are where a large number of spectators gather in, a large refuge is essential, when dangerous situations happen. In this study, evacuation simulation was conducted using three scenarios in order to predict escape behaviors of spectators during the large escape by destruction of safety systems of stadiums and assess escape safety. As the result, the following results and proposals were extracted. Firstly, it is considered that dangerous situations during the security of stadiums should be predicted in advance and concrete plans for a large refuge of spectators have to be established to minimize damage. Secondly, it was found that the reduction in evacuation exits has an important impact on evacuation in an emergency situation. It implies that securing escape exits are quite important. Thirdly, there were areas where spectators stayed, due to blocked escape exits, while they were dispersed and concentrated at once. It demonstrates that security plans considering properties of facilities are required to solve these problems.

  • PDF

Study on Stagnation Factors Analysis and Improvement Methods through an Evacuation Experiment (피난실험을 통한 피난시간 지연요인 분석과 개선방안에 관한 연구)

  • Han, Woon-Hee
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.57-66
    • /
    • 2018
  • The most urgent requirement in the event of disaster and fire in a skyscraper is to establish a system that enables people inside to evacuate safely. Hence, a practical direction needs to give evacuees confidence in the evacuation by reducing the psychological anxiety caused by the relatively large number of people inside and at the same time, the physically prolonged evacuation travel line. Evacuation tests with large numbers of people were conducted three times to solve these challenges and identify phenomena and issues that occurred during the experiment. The results revealed the factors that could cause a delay in evacuation and suggested improvements. The study results of this paper are as follows. First, a recent fire at a multipurpose high-rise resulted in a number of casualties due to a lack of experience with the disaster prevention system. To prevent such cases from occurring in advance, adaptability was achieved by conducting evacuation tests. Second, the data collected in the evacuation simulation statistics and the actual escape drills were compared and analyzed. Third, in the evacuation experiment, a large number of people could not participate in the experiment. The reasons for not participating were analyzed and their impact on the actual evacuation time was confirmed. Fourth, equipment aids were purchased to establish the optimal response measure to the causes of a delay in escape time and the standards for ensuring the safety of the evacuee were specified by developing improvements to minimize the evacuation delay time through comparative before and after analysis of the experiment. These results can be used for fire safety control of skyscrapers to improve the efficiency of evacuation.