• Title/Summary/Keyword: Fire detection sensor

Search Result 147, Processing Time 0.023 seconds

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

Clustering Algorithm for Efficient Energy Consumption in Wireless Sensor Networks (무선 센서 네트워크에서 효율적인 에너지 사용을 위한 클러스터링 알고리즘)

  • Na, Sung-Won;Choi, Seung-Kwon;Lee, Tae-Woo;Cho, Yong-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.49-59
    • /
    • 2014
  • Recently, wireless sensor networks(WSNs) are widely used for intrusion detection and ecology, environment, atmosphere, industry, traffic, fire monitoring. In this paper, an energy efficient clustering algorithm is proposed. The proposed algorithm forms clusters uniformly by selecting cluster head that optimally located based on receiving power. Besides, proposed algorithm can induce uniform energy consumption regardless of location of nodes by multi-hop transmission and MST formation with limited maximum depth. Through the above, proposed algorithm elongates network life time, reduces energy consumption of nodes and induces fair energy consumption compared to conventional LEACH and HEED. The results of simulation show that the proposed clustering algorithm elongates network life time through fair energy consumption.

A Study on Performance Evaluation and Security Measures of U-IT Electrical Safety Integrated Management System's Module (U-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.307-310
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. U-City in order to prevent the disaster of U-IT Power Equipment Performance Module and the security for the safety of the U-City is necessary. In this paper, the power unit of U-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation and security measures will be studied. U-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as U-IT integrated management system for electrical safety and strengthen the security, safety and security with a U-City will contribute to the construction and operation.

  • PDF

Hazardous and Noxious Substances (HNSs) Styrene Detection Using Spectral Matching and Mixture Analysis Methods (분광정합 및 혼합 분석 방법을 활용한 위험·유해물질 스티렌 탐지)

  • Jae-Jin Park;Kyung-Ae Park;Tae-Sung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.1-10
    • /
    • 2022
  • As the volume of marine hazardous and noxious substances (HNSs) transported in domestic and overseas seas increases, the risk of HNS spill accidents is gradually increasing. HNS leaked into the sea causes destruction of marine ecosystems, pollution of the marine environment, and human casualties. Secondary accidents accompanied by fire and explosion are possible. Therefore, various types of HNSs must be rapidly detected, and a control strategy suitable for the characteristics of each substance must be established. In this study, the ground HNS spill experiment process and application result of detection algorithms were presented based on hyperspectral remote sensing. For this, styrene was spilled in an outdoor pool in Brest, France, and simultaneous observation was performed through a hyperspectral sensor. Pure styrene and seawater spectra were extracted by applying principal component analysis (PCA) and the N-Findr method. In addition, pixels in hyperspectral image were classified with styrene and seawater by applying spectral matching techniques such as spectral distance similarity (SDS), spectral correlation similarity (SCS), spectral similarity value (SSV), and spectral angle mapper (SAM). As a result, the SDS and SSV techniques showed good styrene detection results, and the total extent of styrene was estimated to be approximately 1.03 m2. The study is expected to play a major role in marine HNS monitoring.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.