• Title/Summary/Keyword: Fire characteristics

Search Result 2,117, Processing Time 0.03 seconds

Spatial Patterns of Forest Fires between 1991 and 2007 (1991년부터 2007년까지 산불의 공간적 특성)

  • Lee, Byung-Doo;Lee, Myung-Bo
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • For the effective management of forest fire, understanding of regional forest fire patterns is needed. In this paper, forest fire ignition and spread characteristics were analyzed based on forest fire statistics. Fire occurrences, burned area, rate of spread, and burned area per fire between 1991 and 2007 were parameterized for the cluster analysis, which results were displayed using GIS to detect spatial patterns of forest fire. Administrative districts such as cities and counties were classified into 5 clusters by fire susceptibility. Metropolitan areas had fire characteristics that were infrequent, slow rate of spread, and small burned area. However, 4 cities and counties showing fast rate of spread, and large burned area, in the eastern regions of Taeback Mountain range, were the most susceptible areas to forest fire. The next vulnerable cities and counties were located in the West and South Coast area.

On Basic Characteristics of A Pool Fire (Pool fire의 기본적 특성에 관하여)

  • 김명배
    • Fire Science and Engineering
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 1997
  • Pool fire는 본격적인 화재연구의 시작과 더불어 그 구조 및 특성에 대한 연구가 지속적으로 수행되어 왔다. Pool fire는 복잡하고 취급하기 어려운 화재의 제문제들을 비교적 간단하게 다룰수 있게 하면서도 현실과 괴리되지 않는 형태를 가지는 가장 기본적인 형태의 화재로, 학문적 측면뿐 아니라 응용측면에서도 매우 유용한 결과 및 단서를 제공하여 왔다. 따라서, 본고에서는 pool fire의 특성을 화염기저(flame base)부근과 플륨(plume)부근으로 나누어 그 동안 발표되었던 연구결과를 정리하고, 화재 시뮬레이션을 위한 zone 모델기법의 가장 중요한 부분의 하나인 연기량 산정과 플륨해석이 어떤 형태로 연결되는 지를 설명하고자 한다.

  • PDF

Development of User-centered Fire Safety Evaluation Model for School Buildings (교육시설의 사용자 중심 화재안전수준 평가모형 개발)

  • Park, Sung-Chul;Kim, Jin-Wook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.238-239
    • /
    • 2021
  • This study presented the development of a user centered school facility fire safety evaluation model that would support fire safety evaluation, which is globally recognized as being important in terms of school safety, to be more efficiently implemented in the school field mainly by students. The study consisted of five steps. First, actual condition survey tools were developed based on the major fire safety evaluation items derived through literature review. Second, the characteristics of domestic school facilities in terms of fire safety were developed using the survey tools. Third, an evaluation model at a level utilizable by students was developed based on the foregoing characteristics. Fourth, the applicability of the model was verified through a trial application of the model to elementary school students. Finally, legal and institutional improvement plans and fire safety education materials were presented through a policy proposal.

  • PDF

A Comparative Study on the Determinant of Fire Service Budget and Police Service Budget (소방예산과 경찰예산의 결정요인에 관한 비교연구)

  • Kim, Jin-Dong
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.119-130
    • /
    • 2010
  • In the fire and disaster prevention administration of which is not developed in comparison with any other administrative system, the systematic improvement is necessary. For system's more development, financial resource of fire service must be increased sufficiently. If fire service's budget is not allocated sufficiently, fire and disaster were not prevented effectively. This study set up hypothesis based on theoretical background and past research. In this study, dependent variables are fire service budget and police service budget per person Whereas independent variables include demand characteristics, economical characteristics, political characteristics, and previous fiscal year's budget. Statistical methods for the hypothesis's verification are regression analysis, correlation analysis and t-test. The major finding on this study are as follows: First, regression analysis showed that significant variable were past budget variable and economical variable. But political variable and demand variable were not significant except for a emergency medical variable. Second, fire service budget's average was not different significantly from police service budget's average. The above result are contingent upon the theory described in this research. A sustained research and development effort will be necessary if substantial and meaningful progress is to be made in fire service budget.

Numerical Analysis of the Effects of Droplets Characteristics of Water Spray on Fire Suppression (물 분무 액적 특성이 화재진압에 미치는 영향에 대한 수치해석)

  • Lee, Jaiho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effects of the characteristics of droplets of water spray on suppression of fire were analyzed numerically using fire dynamics simulator (FDS) 6.5.2. Additionally, the fire suppression characteristics by the water spray nozzle, including the extinguishing coefficient (EC), droplet size distribution function (SDF), median volumetric diameter (MVD), and droplets per second (DPS), were evaluated in terms of the decreasing normalized heat release rate (HRR) curve and cooling time. It was observed that with increase in the EC, the normalized HRR curve decreased rapidly, and the changing MVD affected the suppression of fire. In case of mono-disperse, the normalized HRR curve decreased slowly with the increase in DPS. On the contrary, in case of multi-disperse, the normalized HRR curve decreased rapidly even with a small increase in DPS.

Surface and Component Analysis of Deteriorated ACSR due to a Flame (화염에 열화된 강심알루미늄연선의 표면 및 성분분석)

  • Kim, Young-Dal;Shim, Jae-Myung;Park, Keun-Seok;Jeong, Yun-Mi;Kim, Jae-Kwang;Byun, Jeong-Seop;Lee, Dae-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1966-1971
    • /
    • 2011
  • Generally, the characteristics of the conductor that was affected by forest fire can be analyzed only when the forest fire is accurately modeled and its effect is identified. Few studies have been conducted with a forest fire model for transmission lines, and no results of the examination of the actual test specimens that were exposed to forest fire have been reported. As the deterioration characteristics of a forest fire are difficult to analyze in the actual field, an environment that was similar to that in the field was used in this study. Deterioration was deposited on a wire using an artificial flame experiment device, to analysis the temperature, surface and component characteristics. It seems that this analysis data in this study can be used as the basic data for the database that can be utilized to analyze wires exposed to forest fire and deterioration and to predict the ACSR wire refurnishment life.

Characteristics of Performance and Back-Fire for External Mixture Hydrogen Fueled Engine without Valve Overlap Period (밸브 오버랩 기간이 없는 흡기관 분사식 수소기관의 성능 및 역화특성)

  • Lee, K.J.;Kang, J.K.;Cong, Huynh Thanh;Noh, K.C.;Lee, J.T.
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.4
    • /
    • pp.374-381
    • /
    • 2007
  • In order to verify the feasibility of expansion of back-fire limit equivalence ratio in the hydrogen-fueled engine with external mixture, the characteristics of performance and combustion are experimentally analyzed with change of intake/exhaust valve timings under the fixed valve overlap period of $0^{\circ}$ CA(non-valve overlap period). These characteristics are also tested for the change of exhaust valve closing timing while intake valve opening timing is fixed to clear the main cause of back-fire occurrence. As the results, the less valve overlap period center is retarded, the more back-fire limit equivalence ratio increases and back-fire does not occurred after TDC. In addition, it was shown that the control of back-fire is dependent on intake valve opening timing than valve overlap period.

Characteristic Analysis of Forest Fire Burned Area using GIS (GIS를 이용한 산불피해지역 특성분석)

  • Lee, Si-Young;Kang, Yong-Seok;An, Sang-Hyun;Oh, Jeong-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.5 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • The forest fire occurrences and burned area are increasing every year since 1990 in Korea, of which 65% is covered by forest. This study attempts to analyze topographic characteristics of forest fire burned area using GIS, and we also applied the statistical analysis based on the fire characteristics such as weather, forest as fuels and topography in small and large forest fire burned areas. The result of the statistical analysis shows that the size of forest fire was related to the slope length, slope degree, wind speed, forest type, and forest continuity.

  • PDF

Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area (산불피해지역에서 숲 가꾸기 실행유무가 산불에 미치는 영향)

  • Lee, Si-Young;Lee, Myung-Woog;Yeom, Chan-Ho;Kwon, Chun-Geun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.153-156
    • /
    • 2008
  • Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area was studied in this work. To investigate the effect of thinning slash in forest fire, Gangneung-si Wangsan-myeon, Ulgin-gun Wonnam-Myeon, Samchok-si Gagok-Myeon, in which forest fire broke out, were selected. As a result that investigated forest fire danger ratio between thinning slash and non-thinning slash, leeward scorching ratio(36%), crown damage ratio(29%), mortality of branch at the former are higher than those at the latter, leeward scorching ratio of tree, where thinning slash is around, is 10%-20% higher than that of independent tree. So I estimate that thinning slash has a some effect on the intensity of forest fire. And the result to investigate damage of forest fire according to tree species shows that leeward scorching ratio of conifer is 5% higher than that of non-conifer, and mortality of branch of the former is 19% higher than that of the latter. It is considered that forest fire may affect directly to a tree trunk if it diffuse to piled thinning tree because there was no space between thinning trees and trees. Furthermore, it was found that re-ignition had a chance to occur due to lots of piled thinning trees.

  • PDF