• 제목/요약/키워드: Fire cases

검색결과 588건 처리시간 0.025초

화재사례분석을 통한 화재피해자 지원체계 구축방안 (Strategy about Support System for Victims of Fire Cases through the Analysis of A Fire Cases)

  • 차종호
    • 산업경영시스템학회지
    • /
    • 제41권4호
    • /
    • pp.196-202
    • /
    • 2018
  • There have been more than 40,000 cases of fires in Korea in the last three years. However, as 'Accidental Fire Liability Act' was judged to be non-conform to the Constitution in 2007, the damages by light mistakes should be compensated. Accordingly, disputes such as compensation claims, litigations and indemnification cases of the victims of fire increased. However, it is so difficult for victims of fire cases to take proper action. So, this study is to help victims of fire cases in the disputes and compensation claims of the victims, and to find actual and practical support system based on the analysis of compensation status. To help victims of fire cases, we need to survey about victims of fire cases with multiple victims. That survey is analyzed to find support plan for victims. Furthermore, to find support plan the current law is needed to be analyzed and reviewed to revision. It is also tried to identify problems in the operation of the Center for victims of Fire currently operated by fire stations and to find countermeasures. In addition, the status of subscription and problem of fire insurance for the compensation for the victims and the method to increase fire insurance subscription rate will be studied.

화재사례를 통한 에어컨의 화재위험성 연구 (Study on Fire Risk of Air Conditioner through Fire Cases)

  • 최승복;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.70-77
    • /
    • 2017
  • 삶의 질이 높아짐에 따라 에어컨의 사용이 증가하고 있다. 따라서 에어컨 사용에 따른 화재 또한 빈번하게 발생하고 있어, 이에 따른 예방대책이 요구된다. 지난 2016년 전국 화재발생은 43,413건 이며, 이중 전기로 인한 화재가 8,655건으로 약 20%를 차지하였다. 전기화재 중 에어컨은 134건으로 약 1.5%를 차지하였고, 불완전접촉, 합선, 트래킹과 같은 다양한 원인으로 발생하는 것으로 나타났다. 본 연구는 에어컨 설치과정에서 실외기에 연결된 전원코드를 임으로 연결하는 접속부위에서 발화한 사례에 대하여 연구하고 그 원인에 따른 예방대책을 제시하여 전기화재로부터 인명과 재산피해를 다소나마 줄이고자 한다.

과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석 (Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석 (A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments)

  • 이정일;임종화
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

침대 매트리스 실물규모 화재안전성 실험 연구 (Experimental study on the reaction-to-fire performance of bed mattress in real scale)

  • 박계원;정재군;양우진;이길용;김인선;정정호;김정욱
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.38-41
    • /
    • 2012
  • This study aims to analyze fourteen cases' HRR & SPR results on bed mattress's reaction-to-fire test in real scale where open flame burner system is used with total heat supply of 27 kW. Most cases show all burning within 5 minutes from the beginning of the test and 3 cases of them reach flashover situation.

  • PDF

화재안전을 위한 건축물 용도별 피난리스크 분석에 관한 연구 (A Study on the Analysis of Evacuation Risk by Building Application for Fire Safety)

  • 진승현;구인혁;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.164-165
    • /
    • 2021
  • In Korea, in the case of fire scenarios in performance design, it is assumed that the sprinkler is not working. In addition, it does not applicate various fire conditions. Therefore it is not enough that the accuracy about fire scenario. In foreign countries, reseach is being conducted to predict the casualities that can occur due to fire in the building space through statistical risk analysis. Also, research is consistently conducting for design that consider the sprinker probability of operation. Therefore, to analyze the fire risk of each building in Korea, the risk was analyzed using statistical data. As a result, the risk of casualties that can occur for each building use was analyzed as 0.6(persons/cases) for residential buildings, 0.25(persons/cases) for sales facilities, and 0.12(persons/cases) for buisiness facilities.

  • PDF

역사문헌 고찰을 통한 조선시대 산불특성 분석 (Analysis of Forest Fires during Chosun Dynasty through Historical Literature Survey)

  • 김동현;강영호;김광일
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.8-21
    • /
    • 2011
  • 본 연구는 역사기록서 분석을 통해 조선시대 518년 동안 산불발생 및 특성에 관한 기록을 고찰하였다. 본 연구에 활용된 역사기록서는 조선왕조실록, 승정원일기, 국역비변사 등록, 각부청의서존안, 철종행장 등으로 조선시대 왕조별로 산불이 기록된 문헌을 조사, 분석하였다. 역사기록문헌에서 기록된 산불 내용은 발생 개요, 산불 종류, 산불피해 등에 관한 사항과 함께 송전(松田)의 산불예방 조치사항 등이 포함되어 있다. 조선시대 역사기록서를 분석한 결과, 산불발생건수가 많았던 왕조는 현종(14건)과 순조(13건)로 강풍으로 인한 산불피해가 극심한 것으로 기록되었고 최대 산불피해는 순조 4년(1804)에 발생한 강원도 동해안 산불로 사망자 61명, 민가 2,600호가 소실되었다. 또한 최대 인명피해가 발생한 산불은 현종 13년(1672) 강원도 동해안 산불로 65명이 사망하였다. 조선시대 산불 발생 원인은 원인미상(42건)>실화(10건)>방화, 낙뢰(3건)>수렵입화(2건)>어린이 불장난, 논밭두렁소각, 가옥화재(각 1건)로 나타났으며 지역별 산불발생은 동해안 지역이 39건(56 %)으로 가장 많이 발생한 것으로 나타났다. 계절별 산불발생은 봄철기간 산불이 46건(73 %)으로 가장 많은 것으로 나타났으며 연중 산불이 가장 많이 발생한 기간은 4~5월로 현재의 산불위험시기와 유사하다. 산불관련자에 대한 처벌의 경우, 방화자 및 실화자에 대해서는 유배, 관직박탈, 효시 등의 처벌기록과 관리지역 책임자에 대한 문책이 기록되어 있다. 결론적으로 조선시대의 경우에도 산불 위험성과 심각성에 대해 여러 문헌에서 기록되어 있는 것을 알 수 있고 현재 우리나라 산불발생 기간 및 지역 패턴과 유사한 것으로 나타났다.

현상학적 관찰에 의한 연소패턴의 식별에 관한 연구(사례를 중심으로) (A Study on the Discrimination of Fire Pattern by the Phenomenological Observation (Focused on the Fire Cases))

  • 최돈묵;최승복;최재성
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.98-110
    • /
    • 2009
  • 화재현장은 바람의 방향과 세기, 가연물의 조건, 건물의 형태 등에 따라 다양하게 소훼형태가 변하기 때문에 발화부와 화재원인을 판단함에 있어 세심한 주의가 필요하다. 본 연구에서는 화재 조사자들이 곤란을 겪고 있는 환기지배와 연료지배에 따른 연소형태, 인화성물질에 의한 바닥재의 탄화형태와 낙화(落火)물에 의한 연소흔적을 사례를 통해 살펴보고 조사방법을 제시하였다.

한국 . 일본 . 미국의 화재발생실태에 대한 비교분석 (1) 화재발생추이 (A Study on Fire Data Analysis in Korea, Japan and USA (1) Number of Fires and Fire Trends)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.74-94
    • /
    • 2004
  • 한국ㆍ일본ㆍ미국의 화재발생 실태를 분석해본 바, 미국은 1977년 3,264,500건에서 2002년 1,687,500 건으로 화재 발생건수가 크게 감소하는 경향에 있고, 일본은 1973년 73,072건을 정점으로 20년이상 6만건 전후의 화재가 발생하고 있으나, 우리나라의 경우에는 1980년 5,438건이던 화재가 급격하게 증가하여 2001년 36,169건까지 발생하였다가 2003년 31,372건의 화재가 발생하였다. 또한 화재통계 처리요령과 화재통계 보고서에 대해서도 분석해본 바, 우리나라가 가장 뒤떨어져 있으며, 화재발생건수의 정확한 산정 등 화재통계의 신뢰성을 확보하기 위한 화재통계 분류의 구체화 및 체계화의 필요성을 확인하였다.

차량화재 사고경향 및 사례분석 (Latest passenger vehicle fire trend and case study based on field investigation data)

  • 신준호;원유진;홍일민
    • 자동차안전학회지
    • /
    • 제6권2호
    • /
    • pp.67-71
    • /
    • 2014
  • Based on the analysis of the actual passenger vehicle fire cases for recent four years (2010~2013), the passenger vehicle fire is increasing annually. Main root cause was analyzed as an electric problem as a 39%. Vehicle fire case by electric problem was mainly caused by use of Non-genuine part. Vehicle fire case by mechanical problem was mainly caused by various oil system maintenance. Vehicle fire case by smoking material was mainly caused by cigarette and disposal lighter. And external fire transition issue and towing mistake fire cases was also confirmed.