• Title/Summary/Keyword: Fire alarms

Search Result 53, Processing Time 0.022 seconds

Importance-Performance Analysis for Developing Convergence Firefighter Helmets (융합 소방용 안전모 개발을 위한 중요도-만족도 연관 분석)

  • Oh, Mi-Ok;Shin, Jong-Kuk;Kang, Myung Chang;Shin, Bo-Sung;Moon, Min-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.109-114
    • /
    • 2016
  • This study executes Importance-Performance Analysis (IPA) on existing firefighter helmet attributes and gathers ideas for improvements from fire-fighting officers to develop a convergence firefighter helmet. The results of empirical analysis were as follows: First, the weight, head fitness, ease of wearing and removal, and ease of managing the existing helmet's attributes need urgent improvement. In addition, fire-fighting officers want to add innovative functions such as oxygen deficiency alarms, poison gas sensors, temperature sensors, and network communication systems to the convergence firefighter helmet under development.

A Design of Dangerous Sound Detection Engine of Wearable Device for Hearing Impaired Persons (청각장애인을 위한 웨어러블 기기의 위험소리 검출 엔진 설계)

  • Byun, Sung-Woo;Lee, Soek-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1263-1269
    • /
    • 2016
  • Hearing impaired persons are exposed to the danger since they can't be aware of many dangerous situations like fire alarms, car hones and so on. Therefore they need haptic or visual informations when they meet dangerous situations. In this paper, we design a dangerous sound detection engine for hearing impaired. We consider four dangerous indoor situations such as a boiled sound of kettle, a fire alarm, a door bell and a phone ringing. For outdoor, two dangerous situations such as a car horn and a siren of emergency vehicle are considered. For a test, 6 data sets are collected from those six situations. we extract LPC, LPCC and MFCC as feature vectors from the collected data and compare the vectors for feasibility. Finally we design a matching engine using an artificial neural network and perform classification tests. We perform classification tests for 3 times considering the use outdoors and indoors. The test result shows the feasibility for the dangerous sound detection.

The Actual Conditions and Needs for Housing Remodeling among the Elderly Households with Adult Children (노부모-성인자녀 동거 가구의 주택개조 실태 및 요구)

  • Kim, Mi-Hee;Oh, Ji-Young
    • Journal of the Korean housing association
    • /
    • v.20 no.2
    • /
    • pp.77-86
    • /
    • 2009
  • The purpose of this study was to examine the household characteristics, the actual residential environment of the elderly living with their offsprings together in Gwangju. We also evaluated their satisfaction with the needs for remodeling of their houses and the different opinions about those things between the elderly and their off springs. We used comparative and descriptive T-test in statistical analysis. The results were as follows. There were more families living in the detached houses than those living in the apartments. The average size of the houses was 100.8 square meters. The mean residence period was 13.5 years. The sons were usually the legal householders. The residents who experienced remodeling before reassigned the furniture and installed the bathtub, which was designed to be sat on comfortably in a common. A few residents installed safety system such as alarms for incident fire or gas, convenient knobs for handling and faucets for running hot or cold water separately. After the installation of alarms, convenient knobs of windows or door, Customer satisfaction for those things were quite high. But that for the installation of safety bar were the lowest in contrast. The most things the old wanted to change were to rearrange bedrooms and bathrooms on the first floor and to decorate them in westernized styles. They didn't need to set up safety bars or shower instrument for modulating heights. The second generation wanted to install the blinds or curtains more than the third generations.

Flame and Smoke Detection for Early Fire Recognition (조기 화재인식을 위한 화염 및 연기 검출)

  • Park, Jang-Sik;Kim, Hyun-Tae;Choi, Soo-Young;Kang, Chang-Soon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.427-430
    • /
    • 2007
  • Many victims and property damages are caused in fires every year. In this paper, flame and smoke detection algorithm by using image processing technique is proposed to early alarm fires. The first decision of proposed algorithms is to check candidate of flame region with its unique color distribution distinguished from artificial lights. If it is not a flame region then we can check to candidate of smoke region by measuring difference of brightness and chroma at present frame. If we just check flame and smoke with only simple brightness and hue, we will occasionally get false alarms. Therefore we also use motion information about candidate of flame and smoke regions. Finally, to determine the flame after motion detection, activity information is used. And in order to determine the smoke, edges detection method is adopted. As a result of simulation with real CCTV video signal, it is shown that the proposed algorithm is useful for early fire recognition.

  • PDF

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

A Study on Real-Time Detection of Physical Abnormalities of Forestry Worker and Establishment of Disaster Early Warning IOT (임업인의 신체 이상 징후 실시간 감지 및 재해 조기경보 사물인터넷 구축에 관한 연구)

  • Park, In-Kyu;Ham, Woon-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.5
    • /
    • pp.1-8
    • /
    • 2021
  • In this paper, we propose the construction of an IOT that monitors foresters' physical abnormalities in real time, performs emergency measures, and provides alarms for natural disasters or heatstroke such as a nearby forest fire or landslide. Nodes provided to foresters include 6-axis sensors, temperature sensors, GPS, and LoRa, and transmit the measured data to the network server through the gateway using LoRa communication. The network server uses 6-axis sensor data to determine whether or not a forester has any signs of abnormal body, and performs emergency measures by tracking GPS location. After analyzing the temperature data, it provides an alarm when there is a possibility of heat stroke or when a forest fire or landslide occurs in the vicinity. In this paper, it was confirmed that the real-time detection of physical abnormalities of foresters and the establishment of disaster early warning IOT is possible by analyzing the data obtained by constructing a node and a gateway and constructing a network server.

Smart Vision Sensor for Satellite Video Surveillance Sensor Network (위성 영상감시 센서망을 위한 스마트 비젼 센서)

  • Kim, Won-Ho;Im, Jae-Yoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.2
    • /
    • pp.70-74
    • /
    • 2015
  • In this paper, satellite communication based video surveillance system that consisted of ultra-small aperture terminals with small-size smart vision sensor is proposed. The events such as forest fire, smoke, intruder movement are detected automatically in field and false alarms are minimized by using intelligent and high-reliable video analysis algorithms. The smart vision sensor is necessary to achieve high-confidence, high hardware endurance, seamless communication and easy maintenance requirements. To satisfy these requirements, real-time digital signal processor, camera module and satellite transceiver are integrated as a smart vision sensor-based ultra-small aperture terminal. Also, high-performance video analysis and image coding algorithms are embedded. The video analysis functions and performances were verified and confirmed practicality through computer simulation and vision sensor prototype test.

Effects of Auditory Warning Types on Response Time and Accuracy in Ship Bridges (선교내에서 청각경보음의 유형이 반응속도와 정확성에 미치는 영향)

  • Ha, Wook-Hyun;Park, Sung-Ha;Kim, Hong-Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.673-680
    • /
    • 2010
  • The effects of different auditory warnings on response time and accuracy were studied in a laboratory ship-bridge work environment. Subjective preference on the type of auditory warnings was also of a primary concern. Twenty five subjects were asked to select an appropriate button for the warning sound presented with three types of auditory warning (abstract sound, auditory icon, and voice alarm) and five levels of warning situation (fire, steering failure, collision, engine failure, and low power). Results showed that the response time and accuracy was significantly affected by the types of auditory warning. The voice alarm resulted in a higher accuracy and subjective preference, as compared to the auditory icon and abstract sound. Regarding the response time, auditory icons and voice alarms were equivalent and superior to abstract sounds. Actual or potential applications of this research include guidelines for the design of integrated ship bridge systems.

A Case Study on the Risk Assessment for Offshore Plant Solid Desiccant Dehydration Package by using HAZOP (HAZOP을 통한 해양플랜트 흡착식 탈수공정 패키지의 위험성평가 및 안전도 향상 방안)

  • Noh, Hyonjeong;Park, SangHyun;Cho, Su-gil;Kang, Kwangu;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.569-581
    • /
    • 2020
  • Since the dehydration packages of offshore plant deal directly with oil & gas, there is a great risk of fire and explosion during operation. Therefore, this study performed risk assessment through HAZard & OPerability (HAZOP) for solid desiccant dehydration package that can remove water component of natural gas in offshore floating liquefied natural gas (LNG) production facilities below 0.1 ppmv. The risk matrix was determined by dividing the likelihood and the severity into five levels separately by asset, life, environment and reputation. The piping & instrumentation diagram (P&ID) of the dehydration package was divided into 9 nodes. Total 22 deviations were assessed in consideration of the adsorption and desorption conversion cycle. A risk assessment based on deviations revealed 14 major hazards. Three representative types of hazards were open/close failure of the control valve, control failure of the heater, and abnormal operation of the regeneration gas cooler. Finally, we proposed the installation of additional safety devices to improve safety against these major hazards, such as safety instrumented functions, alarms, etc.