• 제목/요약/키워드: Fire alarm

Search Result 258, Processing Time 0.026 seconds

Design and Verification of Addressable Automatic Fire Detection System for Existing Apartments (기존아파트의 적용성을 고려한 주소형 자동화재탐지설비의 설계 및 검증)

  • An, Hyunsung
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.105-114
    • /
    • 2022
  • Non-fire activated fire alarms caused by such actions as cigarette smoke, cooking, and high humidity are fire safety risk factors. In such instances, it is important to quickly locate and replace the actuated detector. However, it is difficult to locate those detectors because most do not have an address function. While new apartments can incorporate addressable fire alarm detectors, in existing apartments there are limitations in converting over to addressable detectors due to cost and power line issues. This study developed an efficient address function for fire alarms in existing apartments. The newly developed system consists of the existing receiver, and a proposed addressable repeater and detector. Utilizing an experimental setup, the performance of the proposed address monitoring system was confirmed to be stable and compatible with the receiver and existing detectors.

The effect of cooling rate on electrical properties of ZnO varistor for Fire Alarm Circuit

  • Lee, Duck-Chool;Kim, Yong-Hyuk;Chu, Soon-Nam
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.3-12
    • /
    • 1996
  • The aim of the present study is to find out the effect of cooling rate on the electrical behavior of ZnO varistors. The microstructure, 1-V characteristics and complex impedance spectra were investigated under the change of cooling rates. It is found that at cooling rate $200^{\circ}$/h, nonlinearity and breakdown voltage reached a maximum value which may show that good intergranular layer is formed as a results of proper cooling rate. Complex Impedance spectras were measured as a function of frequency range 100Hz to 13MHz to determine grain and grainboundary resistance. The semicircles were attributed to the dependence of grain and grainboundary resistance on cooling rates.

  • PDF

Development of an USN Based Integrated Open Server System for Disaster Prevention Management (USN 기반 개방형 방재관리 통합시스템 개발)

  • Lee, Jeong-Kyoon;Lee, Ki-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.929-932
    • /
    • 2007
  • The integrated prevention of disaster management system is collected prevention of disaster data from prevention of disaster relation other systems and smart sensor in USN. This system manages fire fighting facility effectively. The relation equipment which is used in existing and network using "Open Protocols" about under using the support system which is integrated effectively as the destroyer. It connects CCTV, the sensitivity environmental sensor, automatic fire detection equipment and security equipment and air flow equipment system using Internet. The System Server was collected monitoring data at the each equipment and processing by operational scenario. It will verified the effectiveness of operational scenario and integrated prevention of disaster management system

  • PDF

Fire Response Education for Hospital Healthcare Providers: A Scoping Review (병원 의료종사자 대상 화재 대응 교육 현황: 주제범위 문헌고찰)

  • Min-Ji Kim;Seung-Eun Lee;Hyun-Eun Park
    • Quality Improvement in Health Care
    • /
    • v.29 no.2
    • /
    • pp.32-46
    • /
    • 2023
  • Purpose: Fire response education is critical for healthcare providers working in hospitals to ensure a safe environment for patients and staff. However, a comprehensive review that thoroughly examines the contents, methodologies, and outcomes of fire response education in hospitals is currently lacking. Methods: We conducted a scoping review by adhering to the framework proposed by Arksey and O'Malley. We searched five electronic databases for literature published after 1990, using the key categories of "hospitals," "fires," and "education." As a result, we identified 15 relevant articles that met our inclusion criteria for the review. Results: Of the 15 articles, 12 had adopted a quasi-experimental design and the remaining 3 had employed a true experimental design. The majority of these studies (11 out of 15) were conducted in the United States, with 4 studies forming committees or teams dedicated to education. Simulation methods were used in 13 studies, while 2 studies had employed a combination of methods. All studies focused on first-response procedures based on RACE (Rescue, Alarm, Contain, Extinguish/Evacuation). Outcome measures included the learners' overall experience, performance in the educational settings, and performance in the field, with all studies reporting positive results following the educational interventions. Conclusion: Our review highlights the importance of multi-professional and multi-departmental educational strategies based on institutional-level initiatives for healthcare providers to create a safe hospital environment.

The Study on the Integrated Emergency Management System using Network GR-type Receiver and Control Desk (네트워크 GR형 수신기와 컨트롤데스크를 이용한 통합방재관리시스템에 대한 연구)

  • Baek, Dong-Hyun;Song, Ho-Bin;Kang, Won-Shun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • The buildings of domestic wear the upper floors and an underground in-depth reconciliation tendency to do and the possibility of fire occurrence at the time of formation accident is coming to be high. Therefore will be scattered to various place and is established and prevention of disaster information of the receiver which will integrate there is a necessity which will manage. In this paper away where each receiver is installed in the fire for the remote monitoring and controld able to connect to the Internet and fiber optic cable that can be networked fire receiver and control desk was constructed. Between each device can be used by the fire, and more depending on the status of monitoring and alarm, control and maintenance can be performed to develop an integrated management system. The system is evaluated by the criteria of the KFI, and for each segment of the signal propagation time to perform experiments confirmed the reliability of the performance.

The Proposal of Installations Standards for Commercial Kitchen Automatic Fire System (상업용 주방자동소화장치 도입과 설치기준 제안)

  • Lee, Changwoo;Kang, Dowoo;Oh, Seungju;Ham, Eungu;Cho, Yongsun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.89-97
    • /
    • 2016
  • According to the statistics released by Ministry of Public Safety and Security, the number of restaurant fires in Korea reached around 2,400 and 169 damages of human life and damages to property was approximately over $8.8 billion for recent 3 years. It could be desirable having automatic commercial fire-extinguishing equipment at commercial facilities excluding housing facilities for the safety, applying at the place first where it has been more risky and expected fire can be occurred relatively because economical burden can be accelerated. In order to do this, adjust its level to meet the same level of the kitchen for 'Specific Target for Fire Fighting' that "gas leak alarm" has be equipped relevant regulations and it is considered and reasonable to expand the limit of application gradually.

Study on the Multi Functional Base Circuit for Fire Detector (다기능형 화재감지기 베이스에 관한 연구)

  • Baek Dong-Hyun;Park Sang-Tae;Lee Bog-Young;Lee Byung-Gon;Chun JI-Yong
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.99-103
    • /
    • 2005
  • This study is the mono signal detector and the multitype detector of mono signal On/Off circuit type. The multi functional base circuit focused on which is made of compatible with exiting fire detector base. The multi functional base circuit generates two fire signals at the same time, so it can link the existing fire alarm system with security system. The base circuit is easily able to be connected to exiting HA or OA facilities, having stability and reliability. As a result of the study, the multi functional base circuit has met the acceptance criteria of related national standards. Also, the security system of input signal can contribute to the smallest loss of lives and the property.

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.

Video smoke detection with block DNCNN and visual change image

  • Liu, Tong;Cheng, Jianghua;Yuan, Zhimin;Hua, Honghu;Zhao, Kangcheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.9
    • /
    • pp.3712-3729
    • /
    • 2020
  • Smoke detection is helpful for early fire detection. With its large coverage area and low cost, vision-based smoke detection technology is the main research direction of outdoor smoke detection. We propose a two-stage smoke detection method combined with block Deep Normalization and Convolutional Neural Network (DNCNN) and visual change image. In the first stage, each suspected smoke region is detected from each frame of the images by using block DNCNN. According to the physical characteristics of smoke diffusion, a concept of visual change image is put forward in this paper, which is constructed by the video motion change state of the suspected smoke regions, and can describe the physical diffusion characteristics of smoke in the time and space domains. In the second stage, the Support Vector Machine (SVM) classifier is used to classify the Histogram of Oriented Gradients (HOG) features of visual change images of the suspected smoke regions, in this way to reduce the false alarm caused by the smoke-like objects such as cloud and fog. Simulation experiments are carried out on two public datasets of smoke. Results show that the accuracy and recall rate of smoke detection are high, and the false alarm rate is much lower than that of other comparison methods.

A study on the efficiency advancement for evacuation of the crews by ship structural improvement (선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구)

  • Kim, Wonouk;Lee, Myoungho;Kim, Jongsu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.342-348
    • /
    • 2014
  • Onshore great fires can normally be extinguished by firefighters using special firefighting equipment and its suitable method. However, offshore fires on the ships are to be extinguished by the crew without any supports from the onshore. Also, crews working on board are exposed to high risk of emergency evacuation due to the complicated structure arrangement of the ships and different accident types such as fire and ship collisions. As most of damage and loss of life in fire are associated with suffocation, shortening of evacuation time is an important factor to improve a survival rate. In this study, visibility in the accommodation area is analyzed by using the temperature and smoke flow which are obtained by the Fire Dynamic Simulator(FDS) as a Three-Dimensional Fire Analysis program to understand the survival rate of the crew upon the fire. The fire doors for most of ships are designed to close automatically when the fire alarm is activated. These automatic closing of the fire doors is a very effective system to delay the spread of flame and smoke flow for the unmanned spaces of the fire protected area. However, if the crew cannot escape within the estimated time, the crew inside the fire protected area will be damaged a lot. In this paper, the comparative analysis between the evacuations by using the fire door from the fire protected area and the suggested fire shielding structure in this study is carried out by the smoke flow rate and the temperature rise rate.