• Title/Summary/Keyword: Fire Safety Module

Search Result 52, Processing Time 0.027 seconds

Risk Assessment of Stationary Hydrogen Refueling Station by Section in Dispenser Module (고정식 수소충전소에서의 Dispenser Module 내 구역별 위험성 평가)

  • SangJin Lim;MinGi Kim;Su Kim;YoonHo Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.1
    • /
    • pp.76-85
    • /
    • 2023
  • Demand for hydrogen as a renewable energy resource is increasing. However, unlike conventional fossil fuels, hydrogen requires a dedicated refueling station for fuel supply. A risk assessment of hydrogen refueling stations must be undertaken to secure the infrastructure. Therefore, in this study, a risk assessment for hydrogen refueling stations was conducted through both qualitative and quantitative risk assessments. For the qualitative evaluation, the hydrogen dispenser module was evaluated as two nodes using the hazard and operability (HAZOP) analysis. The risk due to filter clogging and high-pressure accidents was evaluated to be high according to the criticality estimation matrix. For the quantitative risk assessment, the Hydrogen Korea Risk Assessment Module (Hy-KoRAM) was used to indicate the shape of the fire and the range of damage impact, and to evaluate the individual and social risks. The individual risk level was determined of to be as low as reasonably practicable (ALARP). Additional safety measures proposed include placing the hydrogen refueling station about 100m away from public facilities. The social risk level was derived as 1E-04/year, with a frequency of approximately 10 deaths, falling within the ALARP range. As a result of the qualitative and quantitative risk assessments, additional safety measures for the process and a safety improvement plan are proposed through the establishment of a restricted area near the hydrogen refueling station.

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.

An Experimental Study on the Charging/Discharging Characteristics and Safety of Lithium-Ion Battery System for Submarine Propulsion (잠수함 추진용 리튬이온전지 충방전 특성 및 안전성 확보를 위한 실험적 연구)

  • Kim, Beomseog;Sohn, Seung hyun;Kang, Seokjoong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.4
    • /
    • pp.225-233
    • /
    • 2021
  • Conventional submarine propulsion batteries have mainly used lead acid batteries, which have proved relatively safe, but in recent years, research on mounting lithium-ion batteries to improve the underwater operation capability of submarines is underway in advanced countries such as Japan. Korea has world-class technology in the development of electric vehicles and lithium-ion batteries for energy storage, but fire safety accidents continue to occur in electric vehicles and energy storage lithium-ion batteries. In order to mount the lithium-ion battery in a submarine, it is necessary to check the safety as well as whether the performance is improved compared to the lead acid battery. Through the charge/discharge experiment of this lithium-ion battery module unit, it was possible to measure how much performance was improved compared to the lead acid battery. Safety tests were conducted on the lithium-ion battery module assuming that it was mounted on a submarine, and it was confirmed that safety was secured when applied to a submarine. Since many modules are mounted on actual submarines, it has been confirmed that it can be applied to submarine systems by simulating charge/discharge characteristics through Hardware-in-the Loop(HILS). Through the results of this study, the application of lithium-ion batteries to submarines is expected to significantly improve the sustainability of underwater operations.

A Study on the Drying Performance of the Flux Adhered to Photovoltaic Ribbon (플럭스가 점착된 솔라 리본 건조 연구)

  • Cho, Nam-Cheol;Jeon, Young-Han;Han, Sang-Pil;Kim, Dong-Choon;Lee, Chae-Moon;Jeon, Taeg-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • The photovoltaic ribbon attached the flux reduces the solar module manufacturing process and the pollution. This paper presents an analytical method for solving the continuous flux drying system of photovoltaic ribbon. Also, some experiments of the drying of photovoltaic ribbon are carried out in order to design the drying system. Numerical results indicate the air temperature, the air velocity, the air pressure and the timewise temperature variation of ribbon during drying process. In case of the drier process length is short, 400mm, the photovoltaic ribbon is wet. Thus, another study of drying system is necessary to improve the drying ability. As a result, multi-stage drier system is proposed and shown to be good drying ability.

Study on the Evacuation Time Analysis by Platform Screen Door Opening Rate (스크린도어(PSD)의 개폐율에 따른 피난소요시간 분석에 관한 연구)

  • Kim, Min-Jae;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.59-64
    • /
    • 2016
  • The PSD (Platform Screen Door System) has been installed to enhance the passengers' safety. A total of 592 stations operate the PSD system, which is almost 71.8% of all stations in South Korea. This study compared the opening rate between the PSD and train door, and calculated the exact amount of passengers at peak time. In addition, the evacuation time was simulated by Pathfinder 2015 with the exact input data. Some of the high density stations have extremely high dangerous points about the passengers' evacuation at some situations by the PSD door opening rate. In particular, due to the interference of a fixed door, when it stops at 7 m less than the regular position, its opening rate becomes less than half of the normal state. To solve this problem, it should be made possible to open the fixed door by changing it to an emergency door or improving the PSD module system.

A Study on the Development of a Low-cost Device for Measuring the Optical Smoke Density (광학적 연기밀도 측정을 위한 저가형 장치의 개발에 관한 연구)

  • Kim, Bong-Jun;Cho, Jae-Ho;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.81-88
    • /
    • 2015
  • A low-cost device using the light-extinction method was developed to measure the optical smoke density in various fire experiments in the present study. The relative measurement accuracy of low-cost device was evaluated through the comparison of optical density measured by a high-cost standard device consisting of He-Ne laser, photo detector and various optical components. The low-cost device was composed of laser module, photocell and acrylic board. From the experiments using a smoke generator can be easily adjusted the smoke concentration, it was found that the low-cost device could measure the smoke density within the range of ${\pm}10%$, compared to the standard device. In addition, the reliability of low-cost device was also confirmed in the experiment using a polyethylene flame. Finally, it is expected that the low-cost device developed with real-time measurement and simple installation for measuring the smoke density will be used instead of the high-cost standard device.

Fire Extinguisher Maintenance System using Smart NFC Communication and Real-Time Pressure Measurement (스마트 NFC 통신과 실시간 압력 측정을 이용한 소화기 유지관리 시스템)

  • Park, Byeng-Cheol;Park, Ki-Hong
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.403-410
    • /
    • 2017
  • In this paper, the fire extinguisher maintenance system using smart NFC communication and the real-time pressure measurement is proposed. The proposed system consists of three steps in the flow of information. The first step is to identify the fire extinguisher through NFC tagging in the fire extinguisher module using the smart device. The fire extinguisher appearance check and the real-time pressure measurement is performed in the second step, and the last step sends the check status information to the management server. In particular, the actual pressure value is calculated based on the angle of the green area and the indicating needle. Some experiments are conducted so as to verify the proposed system, and as a result, the proposed system shows that the administrator can effectively control the status information of fire safety check.

A Study on the Development of a Work Operation Process Chart for Smart Distribution Board Fabrication (스마트 분전반 제작을 위한 작업 공정도 개발에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.15-20
    • /
    • 2017
  • This study presented the strength of the materials and parts for smart distribution board fabrication, and developed a work operation process chart for smart distribution board fabrication. This work operation process chart for smart distribution board fabrication complied with SPS-KEMC regulations, and the applicable range and object are less than 1,000 V and 1,000 Hz for the AC distribution board and less than 1,500 V for the DC distribution board. The power supply is 3 phase 4 wires ($3{\Phi}$ 4W), divided into a single phase circuit and a 3 phase circuit. In addition, the circuit was configured so that the leakage current flowing through the distribution line of the load could be monitored in real time by using the sensor module installed at the rear end of the circuit breaker. Therefore, the administrator can easily find the risk factor of the load since engineer can check the leakage current of each distribution line. In addition, if a leakage current greater than standard value flows, it is possible to generate an alarm against a short circuit and cut off the leakage current. The work operation process chart for the smart distribution board fabrication consists of the following steps: raw and subsidiary materials, sheet metal work, tube making, welding, painting, busbar fabrication, assembly and wiring, product inspection, shipment, etc. Moreover, symbols, ${\Delta}$, ${\nabla}$, ${\bigcirc}$, ${\Rightarrow}$, etc. were used according to the type of work and work progress so that workers can easily understand the progress of the work.

Development and Performance Test of Gas Safety Management System based on the Ubiquitous Home (u-home 가스안전관리시스템 개발 및 성능시험)

  • Park, Gyou-Tae;Lyu, Geun-Jun;Kim, Young-Gyu;Kim, Yeong-Dae;Jee, Cha-Wan;Kwon, Jong-Won;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.13-20
    • /
    • 2011
  • In this paper, we proposed a system to raise gas safety management by using the wireless communication module and intelligent gas safety appliances. Our designed systems configure a micom-gas meter, an automatic extinguisher, sensors, and a wallpad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks gas(combustible) leaks and temperature of $100^{\circ}C$ and $130^{\circ}C$. Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals for smoke and CO when occurring gas risk. Gas safety appliances and sensors takes safety measures, and transmit those signal to a wallpad. The wallpad again transmit signal like events to a control server. Users can connect web pages for gas safety through B-ISDN and control and manage them. We hereby devised scenarios for gas safety and risk management, and demonstrated their effectiveness through experiments.

Real-time Network Middleware Supporting Fault-Tolerant Operations for Personal Robot System

  • Choo, Seong-Ho;Park, Hong-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.756-760
    • /
    • 2005
  • By development of a robot technology, personal robot is being developed very actively. Various infra-technologies are accumulated in hardware and software how by internal a lot of research and development efforts, and it is circumstance that actual commodity is announced. But, personal robot is applied to be acting near human, and takes charge of safety and connected directly a lot of works of home security, gas-leakage, fire-warning facilities, or/and etc. So personal robot must do safe and stable action even if any unexpected accidents are happened, important functions are always operated. In this paper, we are wished to show design structures for supporting fault-tolerant operation from our real-time robot middleware viewpoint. Personal robot, in being developed, was designed by module structure to do to interconnect and to interoperate among each module that is mutually implemented by each research facilities or company. Also, each modules can use appreciate network system that is fit for handling and communicating its data. To guarantee this, we have being developed a real-time network middleware, for especially personal robot. Recent our working is to add and to adjust some functions like connection management, distributed routing mechanism, remote object management, and making platform independent robot application execution environment with self-moving of robot application, for fault-tolerant personal robot.

  • PDF