• Title/Summary/Keyword: Fire Risk Analysis

Search Result 496, Processing Time 0.025 seconds

A Development of Consequence Analysis System for Combustible Materials Release Events Based on HTML5 Web (HTML5 웹 기반 가연성 물질 누출 피해영향평가 시스템 개발)

  • Lee, Ugwiyeon;Ji, Hyunmin;Oh, Jeongseok;Cho, Wansu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.39-60
    • /
    • 2019
  • Korea Gas Safety Corporation is developing consequence analysis system for combustible materials release events to enhance risk assessment technology and its efficiency. Unlike general consequence analysis programs, the final consequence area was implemented through ETA analysis based on API-581 standard, and a convenient user interface was constructed based on HTML5-based responsive web technology. In addition, a phase equilibrium module using third-order state equations (such as Peng-Robinson, SRK, and RK) and fugecity was implemented to analyze the mixture quality. Also. using the consequence analysis algorithm introduced in CCPS books and TNO Yellow Book, we developed material leak analysis module, fireball, pool fire, jet fire, flash fire, and vapor cloud explosion consequence assessment module. In addition, the conditions for calculating the safety distance were prepared with using the control values in the EIGA standard, PAC, and Bevi Reference Book.

A Study on Risk Analysis of Social Disaster (사회재난의 재난위해분석에 관한 연구)

  • Lee, Kwan-Hyoung;Yi, Waon-Ho;Yang, Won-Jik
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.15-21
    • /
    • 2016
  • According to the disaster statistics issued by the Ministry of Public Safety and Security, traffic accidents, fire, collapses and others are classified into twenty-three (23) categories. In the past, disasters were mainly caused by the influence of nature, such as typhoon or drought. On the other hand, as society has become city-centered, social disasters' types, frequencies and scales are becoming more diversified and ever-increasing. However, there are no specific criteria and assessment methods that can measure degrees of social disasters-related risks objectively. Therefore, this study targeted traffic accidents, fire and collapses from major social disasters, utilized data that are related to occurrence rate, scale of casualties and scale of property loss in past eight years, and calculated the disaster risk index using the distance (Euclidean distance) between two points on the 3D spatial coordinates, in order to make the objective assessment by social disaster type possible. These results will enable the objective evaluation of risk index of major social disaster to be used as the foundational data when building the national disaster management system.

Analysis on The Characteristics of Occupancy Prediction and The Fire Hazard in Narrow Dwelling Space (협소 거주공간 재실자 특성 및 화재위험성 분석)

  • Lee, Changwoo;Oh, Seungju;Yoo, Juyoul;Kim, Jinsung;Cho, Ahra;Cho, Yongsun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.342-349
    • /
    • 2016
  • The objectives of this study is analysis of the characteristics of fire risk and survey of narrow dwelling space(the Karaoke, Gosiwon etc). The narrow dwelling space has special structure characteristics; the narrow and the complex escape rote. Gosiwon have very separate and exclusive space room, so have the problem a suppression of fire. Furthermore almost Karaokes located in basement have a complex and limitary escape rote. Therefore we should research and development the exploration equipment that search a source of the fire and a emergency rescuer in the scene of the fire.

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.

Fire District Adjustment for Improving Fire Service Vulnerable Areas in Jinju (진주시 소방서비스 취약지역 개선을 위한 소방권역 조정)

  • Yoo, Hwan Hee;Koo, Seul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • This study analyzed the vulnerable areas to the fire service in regard to 119 safety centers, currently established in Jinju city. In this study, the district of fire was examined through the analysis of the OD cost matrix to find the transference or increase methods of the existing centers for improving the fire services. The study results demonstrate that the numbers of 119 safety centers were lacking in comparison with the areas of the administrative district in Jinju. In particular, relocation and the transference or increase of centers were required for the Cheonjeon 119 safety centers, which is the creation area of the National Industrial Complex among five 119 safety centers located in Jinju, and the fire service jurisdiction of Munsan 119 safety centers (including Banseong 119 regional unit), which is the location of a big fire risk due to the increase of population according to the development of the new town. In addition, the OD cost matrix analysis in this study reveals the fact that the time of fire service in the Jeonchon Industrial Complex, which is the significantly vulnerable area, will be reduced from 8 minutes to 3.3 minutes if the current Cheonjeon 119 safety center is moved to Gaho-dong. It indicates that the increase of safety centers in Geumsan-myeon areas, where the population has increased rapidly in recent days due to the development of the new town, is keenly needed.

A Study on Reliability Analysis and Quantitative Risk Analysis for Liquefied Petroleum Gas Station (LPG 충전시설에 대한 신뢰도 분석과 정량적 위험성 분석에 관한 연구)

  • Kim In-Won;Jin Sang-Hwa;Kim Tea-Woo;Kim In-Tae;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.40-48
    • /
    • 2001
  • For a Liquified Petroleum Gas(LPG) station, the reliability analysis, such as Fussell-Vesely importance, risk decrease factor and risk increase factor, was carried out and the risk ranks of events were determined. In order to confirm the degree of the risks identified in the reliability analysis, the quantitative risk analysis was done for the equipments which had the large values of risk ranks. As a result of the importance analysis for the LPG station, the external event was identified as the most riskful event. The defect of construction structure and the pipe corrosion were riskful as well. The result of quantitative risk analysis showed that the length of 46.3 meters were estimated to damage the process equipments by the thermal flux from the catastrophic rupture of storage tank in Boiling Liquid Expanding Vapor Explosion.

  • PDF

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.

A Study of System Analysis Method for Seismic PSA of Nuclear Power Plants (원자력발전소 지진 PSA의 계통분석방법 개선 연구)

  • Lim, Hak Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.159-166
    • /
    • 2019
  • The seismic PSA is to probabilistically estimate the potential damage that a large earthquake will cause to a nuclear power plant. It integrates the probabilistic seismic hazard analysis, seismic fragility analysis, and system analysis and is utilized to identify seismic vulnerability and improve seismic capacity of nuclear power plants. Recently, the seismic risk of domestic multi-unit nuclear power plant sites has been evaluated after the Great East Japan Earthquake and Gyeongju Earthquake in Korea. However, while the currently available methods for system analysis can derive basic required results of seismic PSA, they do not provide the detailed results required for the efficient improvement of seismic capacity. Therefore, for in-depth seismic risk evaluation, improved system analysis method for seismic PSA has become necessary. This study develops a system analysis method that is not only suitable for multi-unit seismic PSA but also provides risk information for the seismic capacity improvements. It will also contribute to the enhancement of the safety of nuclear power plants by identifying the seismic vulnerability using the detailed results of seismic PSA. In addition, this system analysis method can be applied to other external event PSAs, such as fire PSA and tsunami PSA, which require similar analysis.

Numerical study of the Effect of Ventilation Condition on Rolling Stock Fire Growth through the FDS Simulation (환기량 조건이 열차 화재 성장에 미치는 영향성에 대한 FDS 화재 시뮬레이션)

  • Yang, Sungl-Jin;Lee, Chang-Deok;Oh, Ji-Eun;Kang, Chan-Yong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.124-132
    • /
    • 2010
  • To predict and analyze the rolling stock's fire growth is considered not only important factor in estimating hazard analysis of rolling stock, but also a primary factor in aspect of a rail load facility. Because it's could be regarded as a ignition source in risk assesment for the facility i.e. tunnel and station. However, currently, standardized method to predict and analyze the fire growth has not been completed yet. it is due to the fact that fire growth is not only depended on thermal property of interior materials, but also is affected dominantly by various factors such as ignition source (characterized by location, duration, and intensity), train running condition and in/exterior ventilation condition. Especially, ventilation condition is one of the most effective factor to affect fire growth in compartment space as noticed by under-ventilation fire condition. In this study, the effect of each ventilation condition on fire growth and load were examined through the numerical method through FDS (Fire Dynamics Simulator).

  • PDF

Comparative Analysis of Forest Fire Danger Rating on the Forest Characteristics of Thinning Area and Non-thinning Area (숲 가꾸기 실행 및 미 실행지의 임분특성에 따른 산불위험성 비교분석)

  • Lee, Si-Young;Lee, Myung-Woog
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.52-58
    • /
    • 2007
  • The effect of stand-growing-stock characteristics of thinning area and non-thinning area on forest fire was studied in this work. 14 spots were selected from 3 counties such as Yangyang, Injae, and Gapyeong and on-the-spot investigations were performed to evaluate the effect of forest fire. The stand-growing-stock characteristics on the spots were analyzed through the height of tree, breast height diameter, clear length, mortality of branch, forest tree standing crop density, degree of closure, and shrub and grass cover degree. The relation between forest fire and the risk of spread of forest fire were analyzed from the analysis of the stand-growing-stock characteristics. It is considered from this work that the possibility of forest fire is decreased on the thinning area compared to the non-thinning area because of higher clearlength, lower number of tree, lower mortality of branch and higher shrub and grass cover degree.