• Title/Summary/Keyword: Fire Protection Rate

Search Result 188, Processing Time 0.024 seconds

[Retracted]Improving Performance of Foam Proportioner Utilizing Metering Venturi Type ([논문철회]미터링 벤츄리를 이용한 포소화약제 혼합장치의 성능개선)

  • Joo, Seung-Ho;Kong, Ha-Sung;Gong, Ye-Som
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.48-52
    • /
    • 2015
  • In this study, we have evaluated whether the mixing ratio is proper by creating a mixing device for foam proportioner that mainly is employed in practice utilizing a metering venturi type. In case of the mixing ratio for 3%, water under pressure of 76 mm in diameter and the original liquid of a foam fire extinguishing agent of 31.75 mm in diameter have showed up the fluctuation rate just as much as 3.1~3.5% of the mixing ratio. Because water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have showed up 3.3~3.7% of the fluctuation rate, water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have satisfied 3.0~3.9% of performance criterion. And also, in case of the 6% of mixture rate, water under pressure of 76.2 mm in diameter and the original liquid of a foam fire extinguishing agent of 31.75 mm in diameter have showed up the fluctuation rate just as much as 6.4~6.8% of the mixing ratio. Because water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have showed up 6.0~6.8% of the fluctuation rate, water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have satisfied 6.0~7.0% of performance criterion.

Numerical Simulation of Vertical Wall fires II. Propane Fire (수직벽화재의 수치 시뮬레이션 II. 프로판 화재)

  • Park, Woe-Chul;Trouve, Arnaud
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.188-193
    • /
    • 2008
  • Numerical simulation was carried out for a propane fire of mass transfer rate 3g/m^2-s$ on a 1m high vertical wall. The objectives of this study are to confirm the outcomes of evaluation of the simulator through simulation of natural convection, and to compare the results of the wall fire with those of previous studies. It was confirmed that the simulated boundary layer was laminar at C_s=0.2$ while it was turbulent at C_s=0.1$. The z direction velocity showed lack of turbulent mixing as seen in the natural convection case, and the profiles of temperature and velocities were in relatively good agreement with those of experiment and previous simulation. It was found that the air entrainment into the boundary layer was well predicted.

Inhibitory Effects of Aureobasidium pullulans MHAU2101 Isolated from Domestic Pear Blossom Against Fire Blight (국내 배나무 꽃에서 분리한 Aureobasidium pullulans MHAU2101의 화상병 발생 억제 효과)

  • Hyeonseok Oh;Hyo-Won Choi;Yong Hwan Lee;Seung Yeup Lee;Mi-Hyun Lee;Sang-Keun Oh
    • The Korean Journal of Mycology
    • /
    • v.50 no.4
    • /
    • pp.331-341
    • /
    • 2022
  • This study was conducted to identify yeast species isolated from domestic pear blossom through gene sequencing and analysis of morphological characteristics, and to confirm specific yeast species inhibitory effects toward fire blight in immature apples, pears, and crab apple blossoms. Yeast morphological characteristics were consistent with the known characteristics of Aureobasidium pullulans. Nucleotide sequencing of the D1/D2 region of large-subunit (LSU) 26S ribosomal DNA and the internal transcribed spacer (ITS) region confirmed its identity as A. pullulans (MHAU2101). Inoculation of immature fruits with A. pullulans MHAU2101 before exposure to Erwinia amylovora prevented fire blight symptoms in apples and pears. A. pullulans MHAU2101 treated crab apple blossoms had a significantly lower flower infection rate than untreated blossoms, revealing 64% of the potency of streptomycin. The A. pullulans MHAU2101 treated group also displayed lower E. amylovora density in both pistil and hypanthium compared to the untreated group, especially in the hypanthium. This study confirms that A. pullulans MHAU2101 isolated from domestic pear blossom can effectively suppress the onset of fire blight.

Design of Daily Training Protocol for Field Crews Wearing Chemical Protective Clothing for Firefighting and Analysis of Activity (소방용 화학보호복 착용 현장대원의 일상 훈련용 프로토콜 설계 및 활동성 분석)

  • Kim, Si-Kuk;Lim, Woo-Sub;Hong, SungChul
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.110-121
    • /
    • 2018
  • The present article is concerned with a study on the daily training protocol for field crews wearing chemical protection clothing for firefighting and the analysis of activity. To improve coping ability of & secure safety for firefighting crews initially incorporated in the fields of chemical accident & chemical terror, 10 steps in total of daily training protocol have been designed. The designed protocol is largely composed of the extensive activity protocol for daily adaptation of firefighting chemical protection clothing (steps 1, 2, 6, 7 & 9), the precision operation protocol utilizing hands (steps 3, 4 & 5), and the protocol requiring strong physical burdens (steps 8 & 10). According to the measurement results for activity as a result of the protocol, the average maximum heart rate upon wearing the firefighting chemical protection clothing was shown to increase by step 1 20.32%, step 2 18.69%, step 3 25.23%, step 4 34.77%, step 5 27.44%, step 6 30.24%, step 7 25.33%, step 8 22.25%, step 9 22.80% and step 10 20.85% compared with the time of not wearing them. The average maximum breathing rate was shown to increase by step 3 1.92%, step 4 4.11%, step 5 1.24%, step 6 3.95%, step 7 0.93%, step 8 10.23%, step 9 3.36% and step 10 15.10%, except for steps 1 & 2.

Study on the Improvement of Inspection-Related Regulation of Fire Protection Systems and Equipment - Focused on the Fire Administration Process - (소방시설 자체점검 관계법령의 개선방안에 대한 연구 - 소방행정프로세서를 중심으로 -)

  • Lee, Jong Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.188-193
    • /
    • 2019
  • In the past, the risk of fire and the rate of fire occurrence has increased gradually as the quality of life improved due to rapid economic growth, and the government enacted Fire Prevention Act. The existing inspection method was revised considering the rapid increase in the number of fire-fighting objects(hereinafter referred to as specific fire-fighting objects) that require the installation of fire-fighting facilities, and has been applied to this day. On the other hand, unlike the rapid increase in specific fire-fighting objects and the development of fire prevention technologies, the scope of work and inspections by unsuitable inspectors caused a large fire accident, which required improvement of the related laws. This study evaluated, the Act on the relationship of firefighting facilities, which had been implemented previously to identify fire victims, save lives, secure independence of fire inspection agencies, and ensure the accuracy of fire prevention actions.

A Study on the Application Scheme of Fire Identification Considering the Heat Release Rate Characteristics of Inflammable Material (가연물의 발열량 특성을 고려한 화재감식 적용방안에 관한 연구)

  • Kang, Jung-Ki;Oh, Jin-Hee;You, Woo-Jun;Ryou, Hong-Sun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.52-57
    • /
    • 2014
  • The present study suggests the fundamental method for the prediction time of the fire origin by analyzing the combustion phenomenon of inflammable material in the building structure. The heat release rate (HRR) with time variant is evaluated for the interphone as a inflammable material, which is opted from the fire incidents in the stairwell. the fire dynamics simulator (FDS ver. 6.1) is applied in order to analyze the difference of the smoke inflow time to the downstair from the fire event area with various fire pattern. The results show that the maximum inflow time difference for the case of the interphone made from ABS materials is about 4.93 times with the input conditions of heat flux values and the environment in the FDS for the fixed stairwell which composed of total volume $291.3m^3$, floorage $23.3m^2$ and the height of each floor 2.5 m. This research can be practical information for the application method of simulation scheme with experimental data to the fire Identification.

Study on the Conduction Heat Transfer Characteristics According to the Heating Temperature of Lightweight Panel Wall material (경량칸막이 벽체재료의 수열온도에 따른 전도 열전달 특성 연구)

  • Park, Sang-Min;Lee, Ho-Sung;Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.46-56
    • /
    • 2018
  • The paper relates to a study on the conduction heat transfer characteristics according to the heating temperature of lightweight panel wall material. Plywoods, marbles, heat resistant glasses, as well as general gypsum board and fire-proof gypsum board, which have been widely used for lightweight panel wall material, were selected as experiment samples, and heating temperatures were set as $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$ and $600^{\circ}C$. Next, each of the heating temperatures were introduced on the bottom part of the wall material for 30 minutes, and analyses were made on the heat transfer characteristics to the backside part on the top part through conduction. As results of the experiment, the maximum backside temperatures were measured up to $190^{\circ}C$ for a general gypsum board, $198^{\circ}C$ for a fire-proof gypsum board, $189^{\circ}C$ for a plywood, $321^{\circ}C$ for a marble, and $418^{\circ}C$ for a heat resistant glass as heating temperatures were introduced maximum of $600^{\circ}C$. In addition, the maximum change rate of conduction heat transfer were measured up to 85 W for a general gypsum board, 95 W for a fire-proof gypsum board, 67 W for a plywood, 1686 W for a marble, and 3196 W for a heat resistant glass as the maximum heating temperatures were introduced up to $600^{\circ}C$. Also, carbonization characteristics of the wallpapers were measured to visually check the danger of conduction heat transfer, and the results showed that smokes were first generated on the attached wallpapers for the heating temperature $600^{\circ}C$, which were 1021 s for a general gypsum board, 978 s for a fire-proof gypsum board, 1395 s for a plywood, 167 s for a marble, and 20 s for a heat resistant glass, and that the first generation of carbonization were 1115 s for a general gypsum board, 1089 s for a fire-proof gypsum board, 1489 s for a plywood, 192 s for a marble, and 36 s for a heat resistant glass.

Fire Resistance of U-shape Hybrid Composite Beam (신형상 U형 하이브리드 합성보의 내화성능에 관한 연구)

  • Kim, Sung Bae;Kim, Sang Seup;Ryu, Deog Su;Choi, Seng Kwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.4
    • /
    • pp.379-388
    • /
    • 2013
  • This paper aims to experimentally investigate the fire resistance of U-shaped hybrid composite beams protected by spay and paint insulations. Subjected to two and three hours of the Standard ISO fire, the flexural performance of 4.4m beams with/without imposed loadings was examined with respect to failure criteria such as deflection and deflection rate of the mid-span and temperatures measured in the steel section. The results demonstrated that the proposed configuration of the composite beam is able to achieve a very competitive 3-hour fire resistance rating in economical aspects.

Time-Temperature Curve of road tunnel for fire (도로터널 내 화재에 따른 시간-온도 가열곡선 도출)

  • Choi, Min-Jung;Jang, Chang-Il;Lee, Sang-Woo;Kim, Joon-Mo;Won, Jong-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.713-716
    • /
    • 2008
  • This study is performed to propose a standard to evaluate fire protection assessment for concrete structures during a fire on road tunnel. Recently, a number of road tunnels have been rapidly increased and fire risk also multiplyed according to extend tunnel length, due to natural features and environmentally-friendly road construction in domestic. But we have not yet been prescribed appropriate time-temperature curve for tunnel fire. Therefore we presented fire design model and investigated time-temperature curve proposed by a foreign country considering traffic, a kinds of vehicles which are a basis of heat rate.

  • PDF

The Study of Fire Suppression Capability of Sprinkler System for Wooden Cultural Properties (스프링클러 소화설비의 목조문화재 소화성능에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Dong-Chul
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.51-57
    • /
    • 2011
  • The domestic wooden cultural properties applied to the sprinkler extinguishing system was confirmed extinguishing performance through fire experiments. Consists of wooden cultural properties of a fire, a flammable material is vulnerable in terms of. The scale of fire will occur to vary appearance of the initial fire in case of arson. Sprinkler nozzles of the characteristics, the discharging pressure is 1 bar and the flow rate is 80 lpm, applied in this experiment. Fire performance experiments were tested in two separated in each of the scale of the fire and cultural properties. Fire extinguishing performance test results was low in high ceilings and two or more units of the fire scale. Fire growth environment of the actual wooden cultural properties to experimental models when you consider that it is more vulnerable, sprinkler extinguishing system is required sufficient verification in order to apply fire protection of the wooden cultural properties.