• 제목/요약/키워드: Fire Proof

검색결과 104건 처리시간 0.019초

한국 소방방수피복의 착용만족도 및 개선방안에 관한 조사연구 (A Study on the Wearing Comfort of Firefighter's Protective Clothing)

  • 정정숙;이연순
    • 대한가정학회지
    • /
    • 제37권12호
    • /
    • pp.59-67
    • /
    • 1999
  • This study analyzed firefighter's actual wearing condition of turnout gear The results are as fellows: 1. When a firefighter is employed, Korea applies only the minimum of firefighters stature and weight but America applies both the minimum and the maximum. The choice of size is highly related with stature more than chest circumference. 2. The satisfaction degree of thermal barrier is very low, 3%. They used rubber gloves rather than heatproof gloves. This is more serious in small country like 'up', 'myun' than in cities. For laundering, they used sprinkling method with firefighting hose. Firefigthers hoped that their clothes could be classified tv the seasons and fire places. 3. frefighter had high unsatisfaction with the movement of hands and leges in the aspect of movement adjustability, air permeability, weight, body temperature regulation, and breathing in the hygenic aspect, fire resistance, thermal resistance property, water proof, chemical reactivity and electrical conductivity. Thev were also unsatisfied with water proof boots and gloves. They were generally satisfied with helmets but firefighters over 90kg of weight were rather unsatisfied. 4. The satisfaction degree for physical fitness was very low and the items with which they were not satisfied depend on physical features. 5. To develop turnout gear, they wanted changes in design, material and size. Reflection tape need to be replaced with high quality products and they wanted the use of velcro and zipper in fastening system.

  • PDF

화재조사 시 증거물의 효율적인 확보 방안에 관한 연구 (Study of an Efficient Method for Securing Evidence During the Fire Investigation)

  • 예수조;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.43-47
    • /
    • 2016
  • 공판중심주의 강화와 법률시장 개방 등 사법제도의 변화로 인해 화재현장의 해석은 과학적인 증거를 통해 철저한 실체적 진실의 구현을 지향하고 있다. 화재에 대한 실체적 진실 규명의 근거가 되는 물적 증거물에 대한 적정한 수집이 선행되지 않으면 법정에서 증거능력 부정 또는 증명력이 배척되어 조사결과에 대한 신뢰도는 추락하게 된다. 엄정하게 관리된 현장에서 물리적, 화학적으로 변형 우려가 높은 화재 증거물의 특성상 최대한 원형을 보존하도록 채취되어야 하고 채취부터 분석 감정에 이르는 모든 과정이 사진 및 기록으로 유지되어야 하며 이런 과정들에 대한 세부적인 매뉴얼 또는 지침이 규정화 될 필요가 있다. 이런 절차들이 정립되고 조사 기관간 협업 관계가 구축된다면 신뢰도 높은 화재감식 체계가 될 것이다.

비탈형 거푸집에 의한 고강도 콘크리트의 폭렬방지 (Spalling Resistance of High Strength Concrete Using Non-Stripping Form)

  • 유지영;한창평;지석원;한민철;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.865-868
    • /
    • 2008
  • 본 연구에서는 최근 사용이 증대되고 있는 고성능 콘크리트의 폭렬현상을 방지하기 위해 일련의 연구 중 메탈라스 횡구속을 병행한 비탈형 거푸집을 사용한 고성능 콘크리트 RC기둥부재의 내화특성을 검토하였는데, 그 결과를 요약하면 다음과 같다. 유동성 및 공기량은 모두 목표 범위를 만족하였고, 압축강도는 재령 28일에서 80 MPa이상으로 고강도범위를 나타내었다. 폭렬 특성으로는 섬유를 혼입하지 않은 플레인의 경우는 심한 폭렬이 발생하였고, 나일론(이하 NY)+폴리프로필렌(이하 PP) 섬유를 0.05%를 혼입한 경우에는 표면부에만 부분적인 박리폭렬이 발생하였다. 비탈형 거푸집 변화에 따라서는 비탈형 25-20, 비탈형 50-20의 경우에는 모두 마 감재부분에 폭렬이 발생하였는데, 비탈형 50-20의 경우가 비탈형 25-20보다 양호한 폭렬방지 성능을 나타내었다. 비탈형 50-40의 경우는 폭렬이 방지되었는데 질량감소율은 10%이하로 나타났고, 온도이력은 모재표면부 최고온도가 $376.1^{\circ}C$로 가장 우수한 내화 성능을 나타내었다.

  • PDF

예방소방행정과 대비소방행정이 대응소방행정에 미치는 영향 (Effect of Preventive and Prepared Fire Administration on Response Fire Administration)

  • 이원주;임재훈;문광민
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.120-130
    • /
    • 2020
  • 본 연구는 우리나라 소방조직에서 수행되는 예방소방행정과 대비소방행정이 대응소방행정에 미치는 영향을 실증적으로 분석하고자 수행되었다. 이를 위하여 2008년부터 2018년까지 16개 광역자치단체에서 수행된 예방소방행정과 대비소방행정, 그리고 대응소방행정에 대한 패널자료를 이용하여 통계분석을 실시하였다. 독립변인으로 예방소방행정과 대비소방행정을 사용했으며, 종속변인으로 대응소방행정을 사용하였다. 예비소방행정의 하위 변인으로 특정소방대상물 현황분석, 다중이용업 현황분석, 다중이용업 안전시설 완비 증명 발급, 소방특별조사을, 대비소방행정의 하위 변인으로 소방교육을, 대응소방행정의 하위 변인으로 화재진압출동을 사용하였다. 분석결과, 특정소방대상물 현황분석과 소방교육은 화재진압출동에 유의미한 양(+)의 영향을 미치는 것으로 나타났다. 본 연구결과는 소방행정의 효과성을 분석하는 연구에 기초자료로 사용될 수 있다.

화장실을 이용한 층별 피난공간 확보 기술개발 (Development of Technology to Secure Refuge Space by Using Existing Restroom)

  • 김지석;신현준;김정엽;박병직
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.24-30
    • /
    • 2015
  • The fire on a high-rise building would possibly cause fatalities because of ineffective egress due to extended evacuation distance in huge building structure, coupled with dense population, thus requiring secured optimal evacuation method and space. The restroom located in the living space is considered to be useful refuge space which is built with wet pipe and noncombustible materials. This study aimed to develop a system that would make use of the existing restroom as a fire refuge space. Ventilation duct were installed to discharge odor during normal conditions. We could serve the air supply duct to also raise the air pressure in the restroom so as to prevent the toxic gas from gapping around the restroom. The nozzle for the water screen would be installed in restroom door facing the living room to form the water screen which would protect the door. This study is intended to replace the existing refuge space with the restroom in such a way as described above.

농촌 주거지역 쓰레기소각으로 인한 산불화재 개선방안에 관한 연구 (A Study on the Improvement Method of Forest Fire Caused by Waste Incineration at the Farming Residential Area)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.9-15
    • /
    • 2016
  • Currently the forest area is 6,370,000 hectare (ha) which occupies 63.7% in Korea. The forest has good functions such as production of forest products, conservation of national land, prevention of disasters, etc. However constructing houses near the forest area make bad situation like illegal waste incineration by resident. So research subject is forest fire caused by waste incineration place including facility. And this study was conducted about statistical analysis and research analysis of the 100 waste incineration places including facilities at the country town. Statistical analysis shows that March is 27% which percentage is the highest number of forest fire in 10 years' average. The number of forest fire caused by waste incineration is 45 which is the third highest number in the fire statistic. The distance between waste incineration place including facility and forest area is 30m, 40m and 50m. That 40m (36%) is the most common distance from forest area. The types of waste incineration are ground (62%), the temporary facility made with oil drum can (35%) and other made with steel sheet, concrete, etc. The result of this study is that government and local government must conduct the improvement measure to reduce illegal incineration such as waste pickup area made with rain and wind proof type installed near residence, expenses for waste treatment, enlightenment and training, etc. Also considering their age and income are needed for realistic improvement.

로테르담 규칙하에서의 면책사유의 적용상 특징 (the Applying Differences of Excepted Perils in the Rotterdam Rules)

  • 조종주
    • 무역상무연구
    • /
    • 제71권
    • /
    • pp.147-170
    • /
    • 2016
  • International maritime law conventions concerned with cargo liabilities have sought to achieve solutions which will be acceptable to a wide range of states. The Rotterdam Rules was approved by the UN Assembly on 11 December 2008. The Rotterdam Rules are intended to replace The Hague and Hamburg Rules. This paper is comparing The Rotterdam Rules with The Hague and Hamburg Rules for the carrier' liabilities and exceptions in order to find carrier' liability System, the burden of proof and exceptions in the International maritime Rules. The purpose of this paper is considering the carrier's principal recourse for defending himself inmost cargo claims. The first area analyze the transfer of carrier's fundamental Liability system in the International Rules. The second is the matter on the appointment of proof in order to establish liability or to be relieve of liability. And the third is the change of the carrier's possible exclusions from liability in the International maritime Rules. From the result of the said analysis, my paper suggests differences of the exclusions in the Rotterdam Rules comparing with the Hague and Hamburg Rules, and features of the Rotterdam Rules appling exceptions on the basis of the Hague and Hamburg Rules with regard to carrier's liability and burden of proof. The former is the inclusion of three exclusions, the deleted natural fault, and The provision making the carrier responsible for the acts of its servants or agents in the 'fire on the ship' of the Rotterdam Rules. The latter is deleting the principle of overriding obligation related to carrier's obligation of seaworthiness in the Rotterdam Rules, the burden of proof being diverted from the carrier to the carrier and the shipper in the cargo damage caused by two factors(one for which the carrier was liable and the other for which it was excusable) in the new rules.

  • PDF

FDS 이용한 주제어실 화재시 케이블 기능상실시간 평가 (Cable Functional Failure Time Evaluation for a Main Control Room Fire using Fire Dynamic Simulator)

  • 임혁순;김인환;김명수
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.79-85
    • /
    • 2016
  • 원자력발전소의 방화지역에서 전기적인 단락, 지락, 전기회로 개방 등의 전기 문제로 화재가 발생할 수 있다. 전기 화재가 발생할 경우 안전계통 및 관련기기의 안전정지 기능이 상실된다. 이러한 사고를 예방하기 위하여 안전계통은 다중성, 독립성으로 설계되어 있다. 그러나 케이블 화재시 운전원은 오동작, 잘못된 지시 및 계측으로 발전소 상황을 잘 못 판단하여 적절한 조치를 하지 못할 수 있다. 따라서 주제어실 화재시 케이블 기능상실온도에서 최소 운전원 조치 요구시간인 5분은 매우 중요하다. 본 논문에서 주제어실 화재시 케이블의 기능상실온도 시간을 분석하여 운전원 조치시간이 충분한지 평가하여 주제어실 화재에 대한 안전성을 확인하였다.

폭렬방지공법 변화에 따른 RC 기둥부재의 내화특성 (Fire Resistant Properties of the RC Columns Applying Various Splling Prevention Methods)

  • 한천구;배장춘;이종석;이찬영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권3호통권55호
    • /
    • pp.119-126
    • /
    • 2009
  • 본 연구에서는 RC 기둥의 폭렬방지를 위하여 유기섬유의 혼입방식, 내화보드 부착방식, 스프레이 방식의 폭렬방지공법에 따른 내화특성을 검토하였는데, 그 결과를 요약하면 다음과 같다. 굳지않은 콘크리트의 특성으로, 유기섬유의 혼입율이 증가에 따른 유동성은 저하하는 것으로 나타났고, 섬유의 종류에 따라서는 NY섬유를 혼합한 경우 가장 양호하였다. 공기량은 NY섬유가 가장 적게 저하하였고, 그 다음으로 PVA, PP순이었다. 경화 콘크리트의 특성으로, 압축강도는 28일 재령에서 50MPa이상으로 섬유의 혼입율이 증가할 수록 약간 크게 나타났다. 내화시험후 폭렬특성으로, 유기섬유 혼입방식의 경우 PVA섬유를 제외한 PP섬유, NY 섬유는 혼입율 0.05%이상에서 폭렬이 발생하지 않는 것으로 나타났다. 스프레이 방식의 경우는 모든 마감재 부분에서 부분적인 폭렬이 발생하였을 뿐, 모재 콘크리트는 폭렬이 발생하지 않고 본래의 형상을 그대로 유지하는 것으로 나타났다. 또한, 보드방식의 경우는 보편적인 일반 건식공법인 경우를 제외한 건식공법 시공 후 내화페인트로 연결철물을 도포한 경우, 내화모르터로 차폐한 경우, 경량기포 콘크리트로 그라우트 한 경우는 모두 폭렬이 발생하지 않고 본래의 형상을 그대로 유지하고 있었다. 질량감소율은 플레인 콘크리트를 제외한 내화시공공법변화에 따라서 공히 8%미만으로 비교적 양호하게 나타났다.