• 제목/요약/키워드: Fire Performance of External System

검색결과 22건 처리시간 0.022초

$CO_2$ 소화설비 구성부품 성능시험보고 (The Report on Test Results of CO Fire Extinguishing System)

  • 김기옥;이찬주;안병호
    • 방재기술
    • /
    • 통권14호
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

배연창의 개방층 설정방식에 따른 배연성능 평가 연구(제주지역 중심으로) (Performance Evaluation of a Natural Smoke Ventilator in Jeju)

  • 임채현
    • 한국화재소방학회논문지
    • /
    • 제30권1호
    • /
    • pp.6-11
    • /
    • 2016
  • 본 연구에서는 연기로부터 재실자의 안전을 확보하기 위해 설치되는 배연창의 개방층 설정방식에 따른 배연성능을 바람이 강한 제주지역을 대상으로 CONTAM 모델링 분석하였다. 본 연구에서 분석되어진 결과는 육지와 큰 차이를 보이는 제주도의 지형과 특정 외기온도 및 외기풍속 등, 대표적인 변수에 대한 배연창의 배연성능에 대한 평가연구로 경향성을 판단하는데 한정되어야 한다. 분석결과, 배연창의 개방이나 외부 바람의 영향은 건축물의 중성면을 상승시켜 배연창의 배연성능에 많은 영향을 초래하는 것으로 나타났다. 배연창의 개방층 설정방식에 따른 배연성능은 화재층 개방방식이 가장 우수하게 나타났으며 화재층 및 직상층 개방방식은 화재층 개방방식보다 조금 성능이 낮은 것으로 나타났다. 그러나 전 층 개방방식의 경우 배연성능이 아주 떨어져 외기의 다량 유입으로 배연성능을 전혀 기대할 수 없는 것으로 나타났다.

건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구 (An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method)

  • 박정우;조남욱
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.75-85
    • /
    • 2018
  • 2016년 6월 영국 그렌펠 타워 화재는 외단열에 의한 수직화재확산으로 인한 대표적인 피해사례이다. 외단열 공법에서 많이 사용되는 유기단열재는 단열성능이 좋은 반면 화재에 취약한 단점이 있다. 알루미늄 복합패널을 외벽 마감재로 사용하는 외단열 공법에서 알루미늄 내부에 사용되는 플라스틱은 수직 화재확산의 원인으로 지목되고 있다. 알루미늄복합패널을 외벽에 고정하기 위해 사용되는 철재 프레임 때문에 외벽과 외벽 마감재 사이에 중공층이 형성된다. 외벽에 화재가 발생하면 가연성외벽의 연소뿐만 아니라 단열재로부터 발생된 화염이 중공층을 통해 수직으로 급격히 확산되어 인명 및 재산피해가 발생할 수 있다. 국내의 경우 국토교통부고시 2015 - 744에 의한 소재단위 성능시험이 수행되고 있으며, 영국에서는 실제 규모의 화재시험으로 외벽의 수직화재확산 시간의 측정이 가능한 BS8414 시험이 시행되고 있다. 본 연구에서는 현행 국내 고시 기준으로 적합한 준불연 소재의 알루미늄복합패널을 대상으로 영국에서 시행되고 있는 실규모 외벽화재시험(BS 8414)을 수행하여 수직화재확산에 대한 거동 관찰과 현재 마감재료의 소재단위 평가의 한계를 확인하고자 하며, 실제 규모의 화재 시험을 통한 외벽화재 화재확산 방지를 위한 시스템 도입 필요성 확인하고자 한다.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제17권2호
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

Fire Detection Using Multi-Channel Information and Gray Level Co-occurrence Matrix Image Features

  • Jun, Jae-Hyun;Kim, Min-Jun;Jang, Yong-Suk;Kim, Sung-Ho
    • Journal of Information Processing Systems
    • /
    • 제13권3호
    • /
    • pp.590-598
    • /
    • 2017
  • Recently, there has been an increase in the number of hazardous events, such as fire accidents. Monitoring systems that rely on human resources depend on people; hence, the performance of the system can be degraded when human operators are fatigued or tensed. It is easy to use fire alarm boxes; however, these are frequently activated by external factors such as temperature and humidity. We propose an approach to fire detection using an image processing technique. In this paper, we propose a fire detection method using multichannel information and gray level co-occurrence matrix (GLCM) image features. Multi-channels consist of RGB, YCbCr, and HSV color spaces. The flame color and smoke texture information are used to detect the flames and smoke, respectively. The experimental results show that the proposed method performs better than the previous method in terms of accuracy of fire detection.

순차 제어회로 설계기법을 이용한 무장제어장치 개발 (Development of Weapon Control Unit using a Design Technique for Sequence Control Circuits)

  • 박덕배;김형신
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.632-637
    • /
    • 2008
  • 군용 항공기 탑재 무장제어장치는 무장관리시스템의 핵심장비로 조종사의 무장선택, 항공기 상태 및 외부 장착물 장착 상태 등에 따라 선택투하, 비상 투하 및 로켓발사 신호를 생성하여 외부 장착물을 제어한다. 본 논문은 순차 제어회로 설계기법을 이용하여 개발된 무장제어장치의 설계과정 및 성능검증에 대해 기술한다.

섬유복합재봉(FRP ROD)과 고강도 모르터를 이용한 철근 콘크리트 구조물의 휨 보강공법(MFRI) 공법 (Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-performance Mortar)

  • 배기선;박상훈;이상욱
    • Composites Research
    • /
    • 제18권4호
    • /
    • pp.59-65
    • /
    • 2005
  • This report is on the Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-Performance Mortar. The main characteristic of this system is as follow. First, the fiber rods in this system have seven times greater tensile strength than general reinforcing steel bars(re-bar) and the weight is a fifth lighter. Camels coated on the fiber rods' surfaces to improve adhesive strength and pull-out strength. Second, high strength shotcrete mortar is has very good workability and low rebound rate. After installing the Fiber Rods, Shotcrete mortar Is applied or sprayed to finish reinforcement. Finally, MFRI system has excellent fire-resisting performance and sogood tolerance against external environment by inserting fiber rods and reinforcing materials into mortar which has high compressive strength. It is applied to bridge slab, utility box and tunnel of civil engineering works, and beam and slab of building structures.

공학수준 수상함 지휘무장통제체계 범용 모델 개발방안 연구 (On the Development of the Generic CFCS for Engineering Level Simulation of the Surface Ship)

  • 정영란;한웅기;김철호;김재익
    • 한국군사과학기술학회지
    • /
    • 제14권3호
    • /
    • pp.380-387
    • /
    • 2011
  • In this paper, we considered the authoritative representation of Command and Fire Control System(CFCS) for the surface ship that was the engineering level model to develop system specifications and to analyze operational concepts on the concept design phase and to analyze military requirements, effectiveness and performance for the system. The engineering level model of CFCS can be used in simulation independently of the surface ship's type, and also it takes reuse, interoperability, and extension into consideration. The detailed sub-models, internal and external data interface, data flow among each sub-model, sensor and weapon models about the engineering level model of CFCS was defined. It was verified via engineering level simulations according to the V&V process.

준불연 외단열시스템의 역학적 특성에 관한 연구 (Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance)

  • 최기선;하수경;오근영;박금성;류화성
    • 한국건축시공학회지
    • /
    • 제21권5호
    • /
    • pp.507-518
    • /
    • 2021
  • 외단열시스템에서 준불연 성능을 확보한 부착식 탄산칼슘계 복합단열판은 효과적인 단열성능과 화재안전성을 강화한 것으로, 본 연구에서는 준불연 복합단열판을 대상으로 부착식 준불연 외단열시스템의 구조설계 기초데이터를 확보하기 위하여 복합단열판 및 구성재의 역학적 시험을 수행하였다. 국내외 시험규격을 참조하여 시험체를 제작하였으며, 인장강도, 압축강도, 굴곡강도, 전단강도를 시험 평가하였다. 시험결과로부터 준불연 복합단열판의 강도특성치를 도출하였고, 현행 KS M ISO 4898에서 제시하는 최소 요구물성을 확보하고 있는 것을 검증하였다. 또한, 본 연구에서 사용한 준불연 외단열시스템은 지속적 중량 하중을 받지 않는 벽체의 외단열시스템으로 사용이 가능한 것을 확인하였다.

가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로 (A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant)

  • 김영철;조일현;이수경
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.60-66
    • /
    • 2015
  • 본 연구에서는 가스계 소화설비시스템이 설치된 방호구역에 소화농도유지시간 성능실험인 밀폐도 시험(Enclosure Integrity Test)를 진행하여, 성공에 미치는 사전조치요인에 대하여 실험하였다. 국내외에 발전소 방호구역에 사전 조치를 취한 방호구역과 사전 조치를 취하지 않은 방호구역으로 나누어 Enclosure Integrity Test를 진행하였다. 따라서, 사전조치 여부에 따라 시험의 성공률을 알아보고, 각각의 가스계 소화시스템 및 실의 종류에 따른 Enclosure Integrity Test의 실패 요인, 설계 농도 유지시간 및 체적대비 누설면적의 크기를 확인하였다. 그리고 사전조치를 수행하여 Enclosure Integrity Test의 성공률이 증가되는 것을 알 수 있으며, 실패에 의해 반복되는 실험의 수를 줄임으로 인하여 발생되는 비용을 절약할 수 있었다.