• Title/Summary/Keyword: Fire Hazard

Search Result 552, Processing Time 0.023 seconds

A Study on the Fire Safety Performance of Interior Surface Materials in a Building (건축물의 실내건축 재료에 관한 화재안전성 연구)

  • Seo, Su-Eun;Shin, Seung-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

The Safety Program Plan of the LRT(Light Rail Transit) System (경량전철시스템의 안전성구축방안)

  • 정락교;윤용기;목재균;이병송;최규형
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.586-593
    • /
    • 2000
  • This paper describes a safety program plan of the LRT(Light Rail Transit) project. The SPP is a management document that describes the system safety objectives and how they will achieved so it embodies principles, methods and 1)lattices commonly used in the transit industry. In a Preliminary Hazard Analysis phase, the hazard analysis of collision and derailment is carried out. In this paper we make a definition of hazard that hazard is consist of an inner part(means a reliability) and an outer part(means a fire, flood and earthquake). Also safety principles for infrastructure, stations, electric traction system, railway control of system and train are performed.

  • PDF

An Quantitative Analysis of Severity Classification and Burn Severity At the targe-fire Areas Using NBR Index of Landsat Imagery (Landsat NBR지수를 이용한 대형산불 피해지 구분 및 피해강도의 정량적 분석)

  • Won, Myoung-Soo;Koo, Kyo-Sang;Lee, Myung-Bo
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.231-237
    • /
    • 2007
  • To monitor process of vegetation rehabilitation at the damaged area after large-fire is required a lot of manpowers and budgets. However the analysis of vegetation recovery using satellite imagery can be obtaining rapid and objective result remotely in the large damaged area. Space and airbone sensors have been used to map area burned, assess characteristics of active fires, and characterize post-fire ecological effects. Burn severity incorporates both short- and long-term post-fire effects on the local and regional environment. Burn severity is defined by the degree to which an ecosystem has changed owing to the fire. To classify fire damaged area and analyze burn severity of Samcheok fire area occurred in 2000, Cheongyang fire 2002, and Yangyang fire 2005 was utilized Landsat TM and ETM+ imagery. Therefore the objective of the present paper is to quantitatively classify fire damaged area and analyze burn severity using normalized burn index(NBR) of pre- and post-fire's Landsat satellite imagery.

  • PDF

Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area (산불피해지역에서 숲 가꾸기 실행유무가 산불에 미치는 영향)

  • Lee, Si-Young;Lee, Myung-Woog;Yeom, Chan-Ho;Kwon, Chun-Geun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.153-156
    • /
    • 2008
  • Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area was studied in this work. To investigate the effect of thinning slash in forest fire, Gangneung-si Wangsan-myeon, Ulgin-gun Wonnam-Myeon, Samchok-si Gagok-Myeon, in which forest fire broke out, were selected. As a result that investigated forest fire danger ratio between thinning slash and non-thinning slash, leeward scorching ratio(36%), crown damage ratio(29%), mortality of branch at the former are higher than those at the latter, leeward scorching ratio of tree, where thinning slash is around, is 10%-20% higher than that of independent tree. So I estimate that thinning slash has a some effect on the intensity of forest fire. And the result to investigate damage of forest fire according to tree species shows that leeward scorching ratio of conifer is 5% higher than that of non-conifer, and mortality of branch of the former is 19% higher than that of the latter. It is considered that forest fire may affect directly to a tree trunk if it diffuse to piled thinning tree because there was no space between thinning trees and trees. Furthermore, it was found that re-ignition had a chance to occur due to lots of piled thinning trees.

  • PDF

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.

  • PDF

The Fire Hazard of Screwed Electric Contacts Due to Mechanical Vibration at Low Voltage Equipment

  • Choi, Chung-Seog;Kim, Young-Seok;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.18-23
    • /
    • 2005
  • There are many electrical connections in the electric apparatus and most fires due to a fault contact result from a failure or misuse of electric apparatus and installation. The fault contact happens between electrical connections by the loose and the mechanical vibration. In this paper, we have investigated thermal and electrical properties of screwed electric contacts due to the mechanical vibration. The exciter was connected to a signal generator and power amplifier that provided the vibration frequency and amplitude. The vibration, temperature and voltage data were sent to a data acquisition system (DAQ). In the case that fault contact took place, the arc happened between the screwed electric contact and electric wire, heat due to the arc was transmitted to the adjacent insulators, for which the oxide could be generated more. In addition, a spark was generated and the insulator began to melt. Thus, the possibility of electrical fire became the highest in this case. Finally, when the fault contact takes place due to vibration, the hazard of an electric accident is very high.

A Study on the Urban Disaster Management System - Focusing on Fire Service - (도시재난관리체제 운영실태 분석 연구 - 소방을 중심으로 -)

  • Baek, Dong-Seung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.7-12
    • /
    • 2004
  • This study analyzed the current Urban Disaster Management System(UDMS) and proposed improvements, focusing on fire-fighting. We learned the problems with the UDMS empirically, conducting a survey intended for officials in fire station in various prefectures include big city, 6 metropolitan city and Gyeonggi-do. The problems with the UDMS were classified mainly into problems with law operating system, administration system and systematic countermeasures. As a result, it was found that regions that include Seoul and other big cities manage urban disasters better than the prefectures of which Gyeonggi-do and others are parts Consequently, it is desirable to cater appropriate Urban Disaster Management Systems into each of the two parts, one for big cities and the other for prefecture.

A Study on the Emergency Stairway Evacuation of Skyscraper (초고층 건물의 비상계단 대피실험에 관한 연구)

  • Back, Min-Ho;Shin, Ho-Jun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.55-61
    • /
    • 2010
  • In this study, the construction trend of skyscraper was summarized chirologically to examine the characteristics and current, and the issue in evacuation was examined through the case of fire breakout in skyscraper. Based on this, the type of evacuation using the emergency stairway during the fire breakout in skyscraper was decided on six types and empirical experiment was conducted for each type. The issues on the participants that participated in the emergency stairway evacuation experiment from the fire breakout in skyscraper and the difficulties in the evacuation were qualitatively evaluated to summarize each element of hindrance to summarize basic information on emergency stairway evacuation.

Research of the base smoke control planes for high-rise apartment (고층 공동주택의 제연계획에 관한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.89-94
    • /
    • 2004
  • Recently, the cityward tendency of the population has caused the construction of a high rise apartment increased, because it is possible for many people to dwell on a small ground area in an apartment. In the future the number of the constructed high-rise apartment units will also increase, because many people require a better environment and more improved space of their life. However, apartment buildings with many dwellers in spite of small area are exposed to great dangers, particularly fire. So the adaptable control methods of smoke which is the most dangerous to people in a fire were proposed by an analysis on some standards for the fire in this study.