• Title/Summary/Keyword: Fire Exit

Search Result 146, Processing Time 0.021 seconds

Design of Smart Device Assistive Emergency WayFinder Using Vision Based Emergency Exit Sign Detection

  • Lee, Minwoo;Mariappan, Vinayagam;Mfitumukiza, Joseph;Lee, Junghoon;Cho, Juphil;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.101-106
    • /
    • 2017
  • In this paper, we present Emergency exit signs are installed to provide escape routes or ways in buildings like shopping malls, hospitals, industry, and government complex, etc. and various other places for safety purpose to aid people to escape easily during emergency situations. In case of an emergency situation like smoke, fire, bad lightings and crowded stamped condition at emergency situations, it's difficult for people to recognize the emergency exit signs and emergency doors to exit from the emergency building areas. This paper propose an automatic emergency exit sing recognition to find exit direction using a smart device. The proposed approach aims to develop an computer vision based smart phone application to detect emergency exit signs using the smart device camera and guide the direction to escape in the visible and audible output format. In this research, a CAMShift object tracking approach is used to detect the emergency exit sign and the direction information extracted using template matching method. The direction information of the exit sign is stored in a text format and then using text-to-speech the text synthesized to audible acoustic signal. The synthesized acoustic signal render on smart device speaker as an escape guide information to the user. This research result is analyzed and concluded from the views of visual elements selecting, EXIT appearance design and EXIT's placement in the building, which is very valuable and can be commonly referred in wayfinder system.

The Reduced Model Test for the Determination of Ventilation Velocity to Prevent Backflow in Uni-directional Road Tunnel during a Fire Disaster (일방향 도로터널내 화재 발생시 역류를 막는 환기속도결정에 관한 축소모형실험)

  • 유영일;이희근
    • Tunnel and Underground Space
    • /
    • v.8 no.2
    • /
    • pp.107-117
    • /
    • 1998
  • In the case of a fire disaster in a uni-directional road tunnel, it is important to determine the critical ventilation velocity to prevent the backflow travelling toward the tunnel exit where vehicles are stopped. The critical ventilation velocity is horizontal velocity to prevent hot smoke from moving toward the tunnel exit. According to Froude modelling, the model tunnel whcih was 300mm in diameter and 21 m in length was made of acryl tubes. Inner section of acryl tubes was clothed with polycarbonate. 1/20 scaled model vehicles were installed to simulate the situation that vehicles are stopped in the tunnel exit. Methanol in a pool type burner was burned in the middle of tunnel to simulate a fire hazard. In this study, the basis of determining the critical ventilation velocity is the ventilation flow rate that is able to maintain the allowable CO concentration in the tunnel section. We assumed that the allowable CO concentration was backflow dispersion index. Futhermore, We intended to find out CO distribution and temperature distribution according as we changed ventilation velocity. The results of this study were that no backflow happened when ventilation velocity was 0.52 m/s in the case of 5.75 kW. If we adapt these results of a fire disaster releasing 10MW heat capacity in real tunnel which is 400m in length, no backflow happens when ventilation velocity is 2.31m/s. After we figured out dimensionless heat release rate and dimensionless ventilation velocity of model test and those of real test to verify experimental correctness, we tried to find out correlation between experimental results of model tunnel and those of real tunnel.

  • PDF

Development of Emergency Exit Guidance Lamps using the Characteristics of Each Sensor in Case of Fire (화재 발생 시 센서별 특성을 이용한 비상구 유도등 개발)

  • Kim, Jong-Kwan;Jeong, Do-Hyeon;Yu, Yong-Woo;Yang, Min-Hyeok;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1019-1028
    • /
    • 2021
  • Emergency exit guidance lights were designed and manufactured to quickly determine the location of the emergency exit in the event of a fire using a gas sensor, an illumination sensor, a temperature sensor, an Arduino Uno, and a Bluetooth module. This research was designed such that, when a fire breaks out, a red arrow appears as the illuminance value is low and a green arrow as the illuminance value is high to improve visibility when detecting high temperature and smoke. In addition, it is designed to prevent more serious conflagration by applying an alarm sound and text transmission algorithm using a communication module to transmit text messages indicating a 174Hz alarm sound and a fire location to prevent more serious conflagration.

A Study on the Remote Control for Exit Sign Using High Efficiency LED (고효율 LED를 이용한 유도등의 원격제어에 관한 연구)

  • 백동현;홍석표
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2002
  • In the normally, exit sign is always lighting on status by the connected to normal electrical source. So, there are happened to rise of the economical cost such as power consumption, maintenances and repair replacement of lamp etc. This paper are study on the new exit sign circuits by using high efficiency LED that is available for remote control and reduceible to power consumption, maintenance cost by the way of compensation fluorescent and incandescent lamps. As a results on the study, exit sign lamp is capable of control and supervisory in trigger angle by the remote control switch, widely and easily. And then, the response time was very fast in 600〔$\mu$s〕and also it can be find that the rising and fall time of oscillate circuit is maximum 200〔ns〕 as high sensitively. Finally, it obtain to the result that reducible of electrical power consumption and not required for replacement of lamp by using the high efficiency LED lighting source.

A study of evacuation time in a subway carriage fire (지하철 객차 화재발생시 피난 시간에 대한 연구)

  • Kim, Seong-Ryul;Roh, Jae-Seong;Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1313-1318
    • /
    • 2007
  • Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger's evacuation path, it will reduce visibility and can cause fatalities by asphyxiation. This study performs not only fire simulation with CFAST V6 but also evacuation simulation with EXODUS V4 for the purpose of taking measures for passengers's life safety in subway fire. As a result of evacuation simulation without fire, evacuation times are 36 s for EXODUS V4 and simple hand calculation, and when fire is occurred fire, 101 persons evacuated in 32 s. Therefore, a countermeasure of evacuation in subway carriage fire is required to repression of fire and emergency exit.

  • PDF

A Study of Stability Analysis for Exit Light (유도등의 안정성 해석에 관한 연구)

  • Jung, Jong-Jin;SaKong, Seong-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.81-85
    • /
    • 2008
  • In this study, Standards of Lighting Appliance and Standard of Model Approval and Inspection Technology for EXIT LIGHT are compared so as to analyze stability of a exit light which is fire product. Test items, which are not included in Standard of Model approval and Inspection Technology for EXIT LIGHT, are deduced from aforementioned comparison and analysis. Also the derived test items are experimented with a exit light. For a power factor correction, a power factor correction circuit is designed and power factor, crest factor, asymmetry ratio, luminance variation are analyzed. In order to show the validity of designed circuit, current waveform and voltage waveform are measured.

Analysis of RSET According to Exit Installation Standards for the Exterior of a Food Manufacturing Plant Building (식품공장 건축물 바깥쪽으로의 출구 설치기준에 따른 RSET 분석)

  • Park, Ha-Soung;Lee, Jae-Wook;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.201-208
    • /
    • 2024
  • In this study, we investigated whether the evacuation time according to the exit installation standards specified in the building code during a food factory fire is compatible with the evacuation time based on the performance-based design specified by the fire department, in order to determine if evacuation safety is ensured. We used the Pathfinder program to confirm the evacuation time, and experimented with three scenarios for exit installation standards towards the outside of the building: 60m, 80m, and 100m. The target building in the experiment corresponded to the building code's exit installation standard of 100m from each dwelling. The experimental results showed tt in the cases of 80m and 100m, ASET exceeded RSET, indicating tt evacuation safety was not ensured, while in the case of 60m, evacuation safety was maintained. Through this study, it was confirmed tt even when the exit installation standards towards the outside of the building are met, evacuation safety may not be guaranteed.

A Study on the condition of Indoor environmental safety in kindergarten (유아교육기관의 실내 환경 안전 실태에 관한 연구)

  • Choi, Eun-Jin;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.242-246
    • /
    • 2008
  • This study is to research on the condition of safe environment of kindergartens. This study is to supplement the preceding study which was based only on survey to show the result and analyze the condition and problems of the safety of kindergartens to suggest the basic database of indoor environment that cause accident. First as a theoretical study, we analyze the preceding studies according to the related regulations. And we made checklist based on this and visited and investigated two kindergartens where applied for the case study As the result, we could understand factors that can cause accidents from classroom, corridor, door, stairs, balustrade, toilet, kitchen, front door, and fire exit/shelter. Especially, in case of fire exit/shelter, the whole renewal of kindergarten was necessary which is difficult. But, though it can not be advanced right away, they should try to have facility expansion and repair works gradually. And for more study on this, active cooperation from kindergartens are in need.

  • PDF

Survey On Fire Safety Awareness For Revising Fire Safety Guideline (공동주택 화재안전가이드라인 개선을 위한 방재인식조사)

  • Park, SeongKyung;Jin, SeungHyeon;Lee, KyuMin;Kwon, YoungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.144-145
    • /
    • 2017
  • Korean apartment buildings have been manhattanized and enlarged, but it caused increase of fire accidents. Fire accidents such as Uijeongbu apartment fire(2015), and Ssangmoon apartment fire(2016) caused many deads because of a lack of emergency exit route awareness. Follow to advanced research, conducted suervey on fire safety awareness. On this study, it will present the basic data based on the result of the survey to secure the life.

  • PDF

A Basic Study on the Evacuation Plans of Buildings (건축물의 피난계획에 관한 기초적 연구)

  • 고치원
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.1-6
    • /
    • 2000
  • With the "Fire Protection Building Plan" of the Building Center of Japan as a sample, actual evacuation plans used for large scaled and multi-storied buildings are analyzed. Sufficient number of samples were classified into 6 categories. For room evacuation, time to pass through the exit was the most critical point for larger spaces and movement time in the room was the key for smaller evacuation object zone and less number of evacuees. Seen from the location of fire breakout point, it was witnessed that the numbers of crowding at the exits of the fire escape staircase are serious for floor level evacuation. For vertical traffic line, it was actually proved that time to fire escaping floor is problem of higher buildings. It was also proved that special evacuation methods are in practical use in many buildings in japan.

  • PDF