A study of evacuation time in a subway carriage fire

지하철 객차 화재발생시 피난 시간에 대한 연구

  • 김승렬 (중앙대학교 기계공학부대학원) ;
  • 노재성 (중앙대학교 기계공학부대학원) ;
  • 노경철 (중앙대학교 기계공학부대학원) ;
  • 유홍선 (중앙대학교 기계공학부)
  • Published : 2007.05.17

Abstract

Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger's evacuation path, it will reduce visibility and can cause fatalities by asphyxiation. This study performs not only fire simulation with CFAST V6 but also evacuation simulation with EXODUS V4 for the purpose of taking measures for passengers's life safety in subway fire. As a result of evacuation simulation without fire, evacuation times are 36 s for EXODUS V4 and simple hand calculation, and when fire is occurred fire, 101 persons evacuated in 32 s. Therefore, a countermeasure of evacuation in subway carriage fire is required to repression of fire and emergency exit.

Keywords