Assessment of Pulsed Magnetic Field Stimulus by Using Finger Photoplethysmogram and Pressure Pulse Waveform

  • Lee, Jin-Yong;Go, In-Suk;Choi, Jae-Won;Jang, Tae-Sun;Shin, Sang-Hoon;Lee, Hyun-Sook;Hwang, Do-Guwn;Kim, Sun-Wook
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.209-212
    • /
    • 2010
  • Photoplethysmogram (PPG) and pressure pulse waveform (PPW) were compared and evaluated for the efficacy of stimulating knuckles by using the pulsed magnetic field. Both signals were observed simultaneously while the knuckles were exposed for 10 min to the pulsed magnetic field, with maximum field intensity of 0.8 T and transition time of 0.126 msec. After 5 min stimulation of the knuckles, the results showed that the aging indexes calculated from the second derivative of the PPG were increased from -1.913 to 0.072, and that of the PPW from -0.063 to 0.387. However, for the relatively long-term stimulation for 10 min, we found that the values of both the aging indexes of the second derivatives and augmentation index of the PPW returned to the starting level. The changes observed in characteristic factors such as the aging indexes of the second derivatives and augmentation index of the PPW indicate the potential of pulsed magnetic field stimulation as a therapeutic method for the treatment of patients with peripheral vascular disease.

Development of Automatic Ultrasonic Testing Techniques of Low Pressure Turbine Blade of Nuclear Power Plants (원자력 발전소 저압 터빈 동익 자동 초음파 검사 기술 개발)

  • Yang, Seung-Han;Lee, Jeong-Bin;Kim, Young-Ho;Yoon, Byung-Sik;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.371-377
    • /
    • 2004
  • As the turbine running duration in nuclear power plants increases, cracks have been found in the pin finger type blade root area. The nondestructive examination for the blade root area has been carried out by manual ultrasonic examination during the overhaul period, but because of necessity to improve the reliability, we developed an automatic ultrasonic examination system and technique. To demonstrate the performance of the developed automatic ultrasonic examination system, low pressure turbine blades in the 2nd and 3rd stages of nuclear power plants were examined using the developed system. Its applicability nuclear power plant turbine roots of various types was also confirmed.

Giant Cell Tumor of Tendon Sheath in Hand (수부에서 발생한 건초의 거대 세포종)

  • Kang, Ho-Jung;Kim, Kee-Hak;Shin, Kyoo-Ho;Hahn, Soo-Bong;Kang, Eung-Shick
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.1
    • /
    • pp.20-27
    • /
    • 2001
  • Purpose : The giant cell tumor of tendon sheath is the second most common tumor of the hand, but recurred frequently although excision was performed. Authors analyzed and would report clinical findings and postoperative results of it. Materials and Methods : Between January 1991 and December 1998, 38 patients, 41 cases which the authors had performed excisional biopsy to the mass in the hand and diagnosed with the giant cell tumor of tendon sheath, was analyzed with age, sex, chief complaint, symptom duration, involved finger, involved tendon, frequently developed site in fingers, size, multiplicity, radiologic findings and recurrence. The mean duration of follow-up was 13.1 months (5~40 months). Results : Of 38 patients, twenty-nine were female. It is frequent in the fourth decade and mean age was 40.1 years old. The neurological compression symptom was found in 5 cases. The mean duration of symptom was 23.4 months. Flexor tendon was involved in 24 cases. The distal interphalangeal joint area in digit was involved most frequently in 20 cases. Index finger was the most common involved finger (14 cases), and long finger was the second most common (9 cases). All tumors were unilateral. The majority of patients had solitary lesion but one case had multiple lesion. In the radiologic findings, erosion or pressure indentation of bone was seen in 3 cases. All patients were operated by marginal excision. Recurrence rate was 5.1%. Conclusion : The risk factors in giant cell tumor of tendon sheath were female, forth decade, index finger, flexor tendon, and distal interphalangeal joint area. The recurrence was increased in marginal excision of recurred cases, in cases with multiple developed lesions or in multilobular lesion, so wide surgical excision is necessary to prevent recurrence.

  • PDF

Preparation of the Hollow Fiber Type Perovskite Catalyst for Methane Complete Oxidation (메탄의 완전산화 반응을 위한 중공사형 페롭스카이트 촉매 제조)

  • Lee, Seong Woon;Kim, Eun Ju;Lee, Hong Joo;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.297-302
    • /
    • 2018
  • Bead type and hollow fiber type catalyst (HFC, Hollow Fiber type Catalyst) was prepared by $La_{0.1}Sr_{0.9}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ (LSCF1928) perovskite powder catalyst which showed excellent methane complete oxidation characteristics through previous studies. The HFC have a cylindrical shape with an empty interior, and pores can be formed through Phase inversion method so the specific surface area can be remarkably improved. In the case of the bead type catalyst prepared by adding Methyl Cellulose (MC), $SrCO_3$ was produced in addition to the original catalyst composition of LSCF1928 due to the reaction of $CO_2$ emitted from MC and Sr of the catalyst. In the case of the HFC, a single phase perovskite structure was obtained without impurities. The HFC calcined at $700{\sim}900^{\circ}C$ showed pore structure of finger-sponge-finger structure, and 99.9% oxygen conversion rate was achieved through complete oxidation of methane at $475^{\circ}C$. Air gap and spinning pressure condition were changed to control the HFC pore. 2 cm air gap and 7 bar spinning pressure showed the best catalytic performance and achieved oxygen conversion rates of more than 70.65%, 93.01%, and 99.99% at $425^{\circ}C$, $450^{\circ}C$ and $475^{\circ}C$, respectively.

A Study on the Improvement of Welding Method for Ice Evaporator (얼음증발기 용접방법 개선에 관한 연구)

  • Lee, Jeong-Youn;Yoo, Heung-Ryol;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.558-564
    • /
    • 2021
  • The water purifier market has increased rapidly in recent years. The welding technology of the evaporator is a key component that determines the level of ice production and the cold water performance of an ice purifier. The finger type evaporator of an ice purifier can remove ice and is divided largely into an instant heat method and a hot gas method. In the hot gas type evaporator, particularly during the production process, the pinhole phenomenon inside the copper pipe and clogging problems occur intermittently when welding high-pressure pipes due to the high-temperature oxygen welding. Its use in a water purifier can cause a problem in that ice and cold water do not form, and repairs cannot be made on site. To solve this problem, in this study, a cap jig was applied to improve the welding defect of the hot gas evaporator. In addition, the oxygen welding flame size was adjusted so that the heat source could be well supplied to the cap jig, and the effectiveness was confirmed through a wave pressure test, a test, and a thermal shock test.

Effects of Venesection at the Sybsun-points on Blood Pressure and Body Temperature and Pulse Rate in Humans (남녀 대학생에서 십선혈(十宣穴) 사혈(瀉血)이 혈압, 체온 및 맥박수에 미치는 영향)

  • Lee, Dong-Gun;Jeong, Won-Je;Lee, Hyun-Jin;Cho, Hyun-Seok;Kim, Kyung-Ho;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.25 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Objectives : Sypsun-points are located at the tips of all fingers, 0.1 chon(寸) from the finger nails, totaling 10 points on both hands. These points have been used for emergency care, fainting, epilepsy, cerebrovascular accidents, hypertension, unconsciousness, high fever etc. in oriental medicine. The most common technique is bleeding with a needle at these points. We investigated whether Venesection at the Sybsun-points has effects on blood pressure and body temperature and pulse rate in humans aged from 20 to 30 who had no specific past history and whose vital signs are in normal range. Methods : 67 persons were studied from March to June 2008. They were composed of Sample group(n=36) and Normal group(n=31). Both two groups kept a steady state an hour before venesection. In both group, we checked blood pressure and body temperature and pulse rates 6 times( 30min. before and just before treatment, and just after, 30, 60, 90min after treatment). All study environments were same between sample and normal group. But only, normal group didn't carry out venesection at the Sybsun-points. Results : In a comparison of before and after venesection at the Sybsun-points, any Statistical significance was not evaluated. Though pulse rate in sample group was significantly decreased after venesection(p<0.05), it has no statistical significance because normal group's pulse rate was also significantly decreased and between two groups had no statistical difference. Conclusions : Though further study is needed, our findings suggest that venesection at the Sybsun-points has no significant effect on blood pressure and body temperature, and pulse rate in humans who had no specific past history and whose vital signs are in normal range. Also in that case, we may know that pain and tension result from venesection at the Sybsun-points have no significant effect on blood pressure and body temperature and pulse rate.

  • PDF

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

An Experimental Study for Preventing the Resonance of Steam Turbine Blade (증기터빈 블레이드의 공진 방지를 위한 실험 연구)

  • 하현천;이동진;류석주
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.410-415
    • /
    • 2001
  • This paper describes an experimental analysis for improving the stability of blade failure due to the vibration resonance, which happens in the low-pressure steam turbine. Some cracks due to high cycle fatigue were found in the blades of a low-pressure turbine after long time operation. Impact test showed that such failure was mainly caused by the resonance. In other words, since one of the natural frequencies of the grouped blade is very close to the excitation frequency of the nozzle, the resonant vibration leads to a large amplitude of displacement and results in a large amount of stress that may cause fatigue failures in the blades. It is interesting that the blade failures occur only at blades neighboring with the nodal points of the natural vibration mode whose natural frequency is close to the nozzle passing frequency. The effective methods for increasing the reliability against the blade vibration are a heightening the fatigue limit of the blade using an advanced material and a removing the resonance away from the operating speed. It is well known that the removal of theresonance could be obtained by the installation of different types of shrouds, wires, and links between the blades as well as by the chance of the number of nozzles. In the present work, two kinds of modification for avoiding the resonance haute been considered; 1) slot-type finger, 2) long span cover. Full-scale mockup tests have been performed in order to confirm the verification for modification in the shop. Test results show that the use of long span cover is very useful to change the natural frequencies of the grouped blade and to avoid the resonance effectively.

  • PDF

Development of a System for Recognizing Stamp Images (도장영상 인식 시스템의 개발)

  • 송민정;한경숙
    • Journal of Intelligence and Information Systems
    • /
    • v.9 no.1
    • /
    • pp.125-137
    • /
    • 2003
  • In eastern countries stamps have been used more commonly than signatures when approving contracts and documents. Unlike finger prints, stamp images do not share similar patterns to each other and the resolution of stamp images is determined by the input status such as pressure under which stamps are put. This paper discusses the development of a system for recognizing stamp images of Korean or Chinese characters. Recognition of stamp images consists of several steps: acquisition of stamp images from an input device, digitization, contrast stretching, noise removal, and matching. We tested the system on 50 stamp images (20 stamp images of Korean characters, 20 images of Chinese characters, and 10 similar images). There was little difference in discrimination rate between the stamp images of Korean character and those of Chinese characters. 46 stamps images out of 50 were successfully recognized, resulting in 92% discrimination rate. Orientation and pressure under which stamps are put played an important role in determining discrimination rate. Automated stamp image recognition can be made more practical and useful by extending the types of stamp images to ellipses and rectangles and by improving the discrimination rate.

  • PDF

Algorithm for reduction of motion artifact generated in SpO2 measurement (산소포화도(SpO2) 측정시에 발생되는 motion artifact를 reduction하는 algorithm)

  • 한승헌;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.860-863
    • /
    • 2003
  • Pulse oximetry has gained wide spread clinical acceptance in the latter part of the 21st century. The principle of pulse oximetry is based on the red and infrared light absorption features and uses a light emitter with red and infrared LEDs that shines through a reasonably translucent site with good blood flow. There are two methods of sending light through the measuring site : transmission and reflectance. After the transmitted red and infrared signals pass through the measuring site and received at the photodetector, the red/infrared ratio is calculated. But, pulse of oximeters are so sensitive that they may detect pulses when pressure is too low to provide adequate tissue blood flow, that is, SpO2 may decrease due to O2 consumption by the finger of the pulsing but stagnant arterial blood at low pressure or with vasoconstriction. This project has the limitations of pulse oximetry. Therefore, this paper is focused on the resuction of motion artifact that caused by moving when someone measures with SpO2 system.

  • PDF