Flow control of air blowing and vacuuming module using Coanda effect (코안다 효과를 이용한 에어 블로어와 흡입구의 유동 제어)

  • Jeong, Wootae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.115-121
    • /
    • 2017
  • The efficiency of railway track cleaning vehicle for eliminating fine particulate matter (PM10 and PM2.5) in a subway tunnel depends strongly on the structure of the air blowing and suction system installed under the train. To increase the efficiency of underbody suction system, this paper proposes a novel method to use the Coanda effect for the air blower and dust suction module. In particular, through Computational Fluid Dynamics (CFD) analysis, the flow control device induced by the Coanda effect enables an increase in the overall flow velocity and to stabilize the flow distribution of the suction module at a control angle of $90^{\circ}$. In addition, the flow velocity drop at the edge of the air knife-type blower can be improved by placing small inserts at the edge of the blower. Those 4 modular designs of the dust suction system can help remove the dust accumulated on the track and tunnel by optimizing the blowing and suction flows.

Simulation of Various Baffle to Improve Settling Efficiency in Constructed Wetland using CFD (인공습지의 비용 효율적 초기 침강지 설계를 위한 최적 도류벽 구조 모의)

  • Noh, Tae gyun;Jeon, Jechan;Kim, Lee Hyung
    • Journal of Wetlands Research
    • /
    • v.19 no.4
    • /
    • pp.451-458
    • /
    • 2017
  • In this study, the removal efficiency of the wetland in terms of particulate matter and dead water zone through the application of baffles in the sedimentation were simulated with the use of Computational Fluid Dynamics (CFD) to determine the design of a cost-effective constructed wetland. As a result, it was analyzed that the application of the baffle in the sedimentation tank affect the flow and sedimentation rate. Fine particles such as $2{\mu}m$ and $5{\mu}m$ showed high sedimentation rate when the baffles are installed horizontally. large particles such as $10{\mu}m$ and $20{\mu}m$ showed also high deposition rate when the baffles are installed vertically. In addition, the vertical baffles is considered to be more efficient than other baffle types in terms of maintenance since the particulate matter are concentrated in narrow areas. Therefore, it is considered that the selection of the most applicable type of baffle depends on the design purpose of the wetland to be constructed.

A Study on the Sediment Flux in Gwangyang Bay during Spring Tide, March 2003 (2003년 3월 대조기 광양만 부유퇴적물의 유 · 출입에 관한 연구)

  • KIM Seok Yun;LEE Byoung Kwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.6
    • /
    • pp.511-516
    • /
    • 2004
  • As a preliminary study on the sediment flux, concentrations of suspended particulate matter and current speeds were measured at three inlets of Gwangyang Bay during one tidal cycle of a spring tide of March 2003. The suspended sediment flux rate $(g/m^{2}/s)$ at the mouth of Seomjin River (St. K1) was observed to be higher throughout surface layer during ebb tide $(14.3\;g/m^{2}/s)$ and throughout near-bottom layer during the flood tide $(23.2\;g/m^{2}/s),$ resulting in a net upstream-ward transport of$0.9{\times}10^{3}kg/m$ during 13 period. At the inlet toward Yeosu Bay (St. K2), a relatively low rate ($(5.0-6.7\;g/m^{2}/s)$ of sediment flux occurred throughout the water column compared to St. K1, with a depth-integrated net transport of $5.6{\times}10^{3}kg/m$ toward the outer reaches of Gwangyang Bay inlet. At St. K3 located at Gwangyang Bay-side of Noryang Strait, the outward flux toward the Jinju Bay was observed to be dominant during the flood tide $(16.2-23.2\;g/m^{2}/s)$, especially through the mid and near bottom layer, compared to the inward flux throughout the whole water column during the ebb tide $(13.1-19.7\;g/m^{2}/s).$ The net transport at St. K3 was calculated to be $4.0{\times}10^{3}kg/m$ toward the outside of Gwangyang Bay. The outward net transport of suspended sediment at all three inlets seems to be consistent with a trend of bottom sediment texture, which suggests a net movement of sediment from a relatively coarse and poorly sorted inner-bay toward a relatively fine and better sorted outer-bay environment.

Spatial Distribution of Benthic Macroinvertebrates at Three River Weirs in The Namhan River (남한강 본류 3개 보의 저서성 대형무척추동물의 공간적 분포)

  • Kown, Yongju;Kim, Jin-Young;Kim, Piljae;Kim, Jungwoo;Kim, Jeong-KI;Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.1
    • /
    • pp.36-47
    • /
    • 2020
  • Three large scale weirs were constructed 2010 - 2011 in the Namhan river, Korea. The purpose of this study was to investigate the spatial distribution of benthic macroinvertebrates and the influence of environmental factors at the weirs 2014 - 2015. The number of species was higher in the riparian zone than in the transition or the limnetic zone. This seems to be because of the diversification of microhabitats and food sources according to the development of littoral zones. From the riparian zone to the limnetic zone, the individual abundance proportion of gathering collectors among functional feeding groups decreased, and that of filtering collectors increased. In the limnetic zone, sprawlers and climbers among habitat orientation groups decreased, and burrowers increased. This means that coarse particulate organic matter originated from land or riparian zone was transformed to fine particulate organic matter in the limnetic zone. Asian clam (Corbicula fluminea) and chironomids were dominant species based on individual abundance. Asian clam, a major taxon considering biomass, was abundant toward the limnetic zone. This is becasue of the shallow depth, suitable water current, slightly coarse substrate, and good water quality. There was no significant relationship between the water quality and the characteristics of the benthic macroinvertebrate community because the water quality was spatially not heterogenous. The more influential factors for benthic community were physical factors, especially water depth. Water depth showed a markedly significant correlation with Shannon-Weaver's species diversity (r=-0.90), Margalef's species richness (r=-0.82), and McNaughton's dominance (r=0.86). Water depth showed a positive correlation (r=0.68) with the Kong and Kim BMSI (Bentic Macroinverebrates Streambed Index), and this may be related to the coarse substrate of the limnetic zone.

Dust collection system optimization with air blowing and dust suction module (에어 블로어와 흡입기능을 가진 미세먼지 흡입시스템의 최적화)

  • Jeong, Wootae;Kwon, Soon-Bark;Ko, Sangwon;Park, Duckshin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.290-297
    • /
    • 2016
  • The performance of track cleaning trains to remove accumulated fine particulate matter in subway tunnels depends on the design of the suction system equipped under the train. To increase the efficiency of the suction system under the cleaning vehicle, this paper proposes a novel dust suction module equipped with both air blowing nozzles and a dust suction structure. Computational Fluid Dynamics (CFD) analysis with turbulent flow was conducted to optimize the dust suction system with a particle intake and blowing function. The optimal angle of the air blowing nozzle to maximize the dust removal rate was found to be 6 degrees. The performance of the track cleaning vehicle can be increased by at least 10 percent under an operation speed of 5km/h.

A Study on the Trends of Air Quality and Characteristics in Seosan Area of Korean Penninsula (서산지역의 대기질 경년변화 특성에 관한 연구)

  • Shon, Byung-Hyun;Park, Tong-So
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.779-786
    • /
    • 2008
  • This study was performed to evaluate the characteristics of current air quality and to examine the monthly and yearly variation of $SO_2,\;O_3,\;CO,\;NO_2$, and fine particulate matter(PM-10) concentration in Seosan for the period of 1998-2006. During the recent 3 years, from 2004 to 2006, the yearly mean concentration of $SO_2,\;NO_2$, and PM-10 remained stability but CO and $O_3$ are gradually decreased. The monthly mean concentration of $NO_2$, CO, and $SO_2$ were high in the winter season and decreased steadily to the summer season, but the maximum concentration of $O_3$ and PM-10 appeared in the springtime. The number of days exceeding 24-hour standards for PM-10 were 54 times at Dokgodri and 25 times at Dongmundong. The number of sampling days exceeding the 1-hour and 8-hour standards for $O_3$ were 68 and 210 times at Dongmundong and at Dokgotri 93 and 213 times, respectively.

Comparison of Ground-Based Particulate Matter Observations in the Seodaemun-gu District, Seoul (서울 서대문구 지상 미세먼지 관측 비교)

  • Koo, Ja-Ho;Lee, Seoyoung;Kim, Minseok;Park, Joonghee;Jeon, Soo Ahn;Noh, Hyunsuk;Kim, Jhoon;Lee, Yun Gon
    • Atmosphere
    • /
    • v.28 no.4
    • /
    • pp.469-477
    • /
    • 2018
  • We performed the comparison of observed $PM_{10}$ and $PM_{2.5}$ at both the Yonsei University and the AIRKOREA site in the same Seodaemun-gu district, Seoul from March to December 2016. Generally, the moderate correlations between two sites were found for both $PM_{10}$ and $PM_{2.5}$, but monthly difference was somewhat occurred, implying that the measurement situation is not equally maintained even in a closely located area. Particularly correlations became weaker in June and July, which seems the impact of rainy conditions. Correlations between two stations were higher for $PM_{10}$ compared to $PM_{2.5}$, probably indicating the spatially larger difference of fine mode particle. Monthly mean variation was similar between two sites showing a maximum in March and minimum in August. Diurnal variation was somewhat different: morning peak at Yonsei University but evening peak at the Seodaemun-gu AIRKOREA site, reflecting the difference of local air condition. We also compared the extent of $PM_{10}$ and $PM_{2.5}$ according to the local wind speed and direction. In general, the level of particulate matter was high when the wind is blowing from the northwestern area with low wind speed, meaning the high accumulation effect of transported air particles. Findings of this study can be usefully considered for the investigation about the discrepancy of aerosol measurement in a local scale.

Development of a Deep Learning-based Midterm PM2.5 Prediction Model Adapting to Trend Changes (경향성 변화에 대응하는 딥러닝 기반 초미세먼지 중기 예측 모델 개발)

  • Dong Jun Min;Hyerim Kim;Sangkyun Lee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.6
    • /
    • pp.251-259
    • /
    • 2024
  • Fine particulate matter, especially PM2.5 with a diameter of less than 2.5 micrometers, poses significant health and economic risks. This study focuses on the Seoul region of South Korea, aiming to analyze PM2.5 data and trends from 2017 to 2022 and develop a mid-term prediction model for PM2.5 concentrations. Utilizing collected and produced air quality and weather data, reanalysis data, and numerical model prediction data, this research proposes an ensemble evaluation method capable of adapting to trend changes. The ensemble method proposed in this study demonstrated superior performance in predicting PM2.5 concentrations, outperforming existing models by an average F1 Score of approximately 42.16% in 2019, 58.92% in 2021, and 34.79% in 2022 for future 3 to 6-day predictions. The model maintains performance under changing environmental conditions, offering stable predictions and presenting a mid-term prediction model that extends beyond the capabilities of existing deep learning-based short-term PM2.5 forecasts.

Physicochemical Properties of Indoor Particulate Matter Collected on Subway Platforms in Japan

  • Ma, Chang-Jin;Matuyama, Sigeo;Sera, Koichiro;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.2
    • /
    • pp.73-82
    • /
    • 2012
  • This study was aimed to thoroughly estimate the characteristics of indoor particulate matter (PM) collected on subway platforms by the cooperative approach of semi-bulk and single particle analyses. The size-resolved PM and its number concentration were measured on the platform in a heavily traveled subway station in Fukuoka, Japan. Particle Induced X-ray Emission (PIXE) and micro-PIXE techniques were applied to the chemical analyses of semi-bulk and single particle, respectively. There was the close resemblance of timely fluctuation between PM number concentration and train service on the third basement floor (B3F) platform compared to the second basement floor (B2F) and its maximum level was marked in rush hour. Higher number counts in large particles ($>1{\mu}m$) and lower number counts in fine particles ($<1{\mu}m$) were shown on the platform compared to an above ground. PM2.5 accounted for 58.2% and 38.2 % of TSP on B3F and on B2F, respectively. The elements that were ranked at high concentration in size-resolved semi-bulk PM were Fe, Si, Ca, S, and Na. The major elements tending to have more elevated levels on B3F than B2F were Fe (4.4 times), Ca (17.3 times), and Si (46.4 times). Although concentrations were very low, Cr ($11.9ng\;m^{-3}$ on B3F, $2.4ng\;m^{-3}$ on B2F), Mn ($3.4ng\;m^{-3}$ on B3F, $0.9ng\;m^{-3}$ on B2F), and Pb ($0.6ng\;m^{-3}$ on B3F, $1.6ng\;m^{-3}$ on B2F) were detected from PM2.5. Individual PM was nearly all enriched in Fe with Si and Ca. Classifying and source profiling of the individual particles by elemental maps and particle morphology were tried and particles were presumably divided into four groups (i.e., train/rail friction, train-rail sparking, ballast/abrasive, and cement).

Comparison of Chemical Composition of Particulate Matter Emitted from a Gasoline Direct Injected (GDI) Vehicle and a Port Fuel Injected (PFI) Vehicle using High Resolution Time of Flight Aerosol Mass Spectrometer (HR-ToF-AMS)

  • Lee, Jong Tae;Son, Jihwan;Kim, Jounghwa;Choi, Yongjoo;Yoo, Heung-Min;Kim, Ki Joon;Kim, Jeong Soo;Park, Sung Wook;Park, Gyutae;Park, Taehyun;Kang, Seokwon;Lee, Taehyoung
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.51-56
    • /
    • 2016
  • Particulate matter (PM) in the atmosphere has wide-ranging health, environmental, and climate effects, many of which are attributed to fine-mode secondary organic aerosols. PM concentrations are significantly enhanced by primary particle emissions from traffic sources. Recently, in order to reduce $CO_2$ and increase fuel economy, gasoline direct injected (GDI) engine technology is increasingly used in vehicle manufactures. The popularization of GDI technique has resulted in increasing of concerns on environmental protection. In order to better understand variations in chemical composition of particulate matter from emissions of GDI vehicle versus a port fuel injected (PFI) vehicle, a high time resolution chemical composition of PM emissions from GDI and PFI vehicles was measured at facility of Transport Pollution Research Center (TPRC), National Institute of Environmental Research (NIER), Korea. Continuous measurements of inorganic and organic species in PM were conducted using an Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS). The HR-ToF-AMS provides insight into non-refractory PM composition, including concentrations of nitrate, sulfate, hydrocarbon-like and oxygenated organic aerosol, and organic mass with 20 sec time resolution. Many cases of PM emissions during the study were dominated by organic and nitrate aerosol. An overview of observed PM characteristics will be provided along with an analysis of comparison of GDI vehicle versus PFI vehicle in PM emission rates and oxidation states.