충전율의 변화가 밀폐형 2-상 열사이폰의 열전달 특성에 미치는 영향에 관한 연구 (The Effect of the Fill Charge Ratio on the Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon)

  • 박용주;홍성은;김철주
    • 대한기계학회논문집B
    • /
    • 제26권12호
    • /
    • pp.1646-1654
    • /
    • 2002
  • A two-phase closed thermosyphon was one of the most effective devices in the removing heat because of its simple structure, thermal diode characteristics, wide operating temperature range and so on. In this study, a two-phase closed thermosyphon(working fluid PFC(C6F14), container copper(inner grooved surface)) was fabricated with a reservoir which can change the fill charge ratio. The experiments were performed in the range of 50~600W heat flow rate and 10~70% fill charge ratio. The results were compared with some correlations that were presented by Rohsenow and Immura et al. in the evaporator, by Nusselt, Gross and Uehara et al. in the condenser and by Cohen and Bayley, Wallis, Kutateladze and Faghri et al. in heat transfer limitation etc.. The heat transfer coefficient at the evaporator increased with the input power. However the effect of the fill charge ratio was nearly negligible. At the condenser, it showed an opposite trend to the evaporator and with increase of the fill charge ratio, showed some enhancement of heat transfer. The heat transport limitation was occurred by the dry-out limitation for small fill charge ratio(10%) and presented about 100W. For the case of large fill charge ratio(Ψ$\geq$40%), it was occurred by the flooding limitation at about 500W.

직교.대향류 충진재를 이용한 하이브리드 냉각탑에 대한 실험적 연구 (The Experimental Study of the Hybrid Cooling Tower using Cross and Counter Type Fills)

  • 전철호;이호생;이호출;문춘근;김재돌;김은필;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.236-237
    • /
    • 2005
  • An experimental study on the Hybrid Cooling Tower has been done having a rated capacity of 3RT. Counter flow type fill, cross flow type fill and hybrid-type fill which is combined with two type fills as previously stated having a height of 0.3m have been used in the 0.8m${\times}$0.4m${\times}$1.9m dimensional tower respectively. The heat exchanger is consisting of 2 or 3 rows. The relevant temperatures and the velocities were selected based on the typical Korean weather for the year round operation of the tower. The cooling capacity of the tower is explained with respect to varying air inlet velocities, wet-bulb temperatures, and air to cooling water volume flow rate ratio (L/G ratio). The capacity of the hybrid-type fill was much superior to other fills, but hybrid-type fill shows higher pressure drop.

  • PDF

A Comparison of the Heat Transfer Performance of Thermosyphon Using a Straight Groove and a Helical Groove

  • Han Kyuil;Cho Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2296-2302
    • /
    • 2005
  • This study is focused on the comparison of heat transfer performance of two thermosyphons having 60 straight and helical internal grooves. Distilled water has been used as working fluid. Liquid fill charge ratio defined by the ratio of working fluid volume to total internal volume of thermosyphon, the inclination angle and operating temperature were used as experimental parameters. The heat flux and heat transfer coefficient are estimated from experimental results. The conclusions of this study may be summarized as follows; Liquid fill charge ratio, inclination angle and geometric shape of grooves were very important factors for the operation of thermosyphon. The optimum liquid fill charge ratio for the best heat flux were $30\%$. The heat transfer performance of helically grooved tube was higher than that of straight grooved tube in low inclination angle (less than $30^{\circ}$), but the results were opposite in high inclination angle (more than $30^{\circ}$). As far as optimum inclination angle concerns, range of $25^{\circ}\~30^{\circ}$ for a helically grooved tube and about $40^{\circ}$ for a straight grooved tube are suggested angles for the best results.

A Study on the Improvement of Heat Transfer Performance in Low Temperature Closed Thermosyphon

  • Han, Kyu-Il;Yee, Seok-Su;Park, Sung-Hyun;Lee, Suk-Ho;Cho, Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제16권9호
    • /
    • pp.1102-1111
    • /
    • 2002
  • The study focuses on the heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal grooves. Three different working fluids(distilled water, methanol, ethanol) are used with various volumetric liquid fill charge ratio from 10 to 40%. Additional experimental parameters such as operating temperature and inclination angle of zero to 90 degrees are used for the comparison of heat transfer performance of the thermosyphon. Condensation and boiling heat transfer coefficients, heat flux are obtained using experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, liquid fill charge ratio, number of grooves and inclination angle are very important factors for the operation of thermosyphons. The relatively high rate of heat transfer is achieved when the thermosyphon with internal grooves is used compared to that with plain tube. The optimum liquid fill charge ratio for the best heat transfer performance lies between 25% and 30%. The range of the optimum inclination angle for this study is 20$^{\circ}$~30$^{\circ}$ from the horizontal position.

전력변환 반도체 냉각용 PFC(FC-72) 밀폐형 2상 열사이폰의 열전달 한계에 관한 연구 (A Study on the Heat Transport Limitations of a PFC(FC-72) Two-Phase Closed Thermosyphon for Cooling Power Semiconductors)

  • 박용주;홍성은;김철주
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.725-733
    • /
    • 2002
  • In this study, the heat transport limitations of a two-phase closed thermosyphon were investigated. For the test, a two-phase closed thermosyphon ($L_t/: 600 mm,\;L_e:105mm,\;L_a:75mm,\;L_c:420mm,\;D_o:22.2mm,$ container: copper (inner grooved surface), working fluid: PFC ($C_6F_14$) was fabricated with a reservoir that can change the fill charge ratio. The following was imposed as the factors on the heat transport limitations of a two-phase closed thermosyphon. 1) Fill charge ratio of the working fluid. 2) Tilt angle of the longitudinal axis. From tile experimental data, some results were obtained as follows. When the fill charge ratio was relatively small ($\psi$20%), the heat transport limitation occurred about 100W by dry-out limitation. However over 40%, it shelved nearly constant value (500 W) by flooding limitation. The heat transport limitation according to the tilt angle increased smoothly until the tilt angle was $60^{\circ}$,/TEX>, after then decreased slowly.

준설토의 유실율 결정에 관한 연구 (A Study on the Determination of Loss Ratio in Dredged Soils)

  • 김석열;김승욱;노종구
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.606-611
    • /
    • 1999
  • Recently , the hydraulic fill method is commonly used in many reclamation projects due to lack of fill materialss. The method of hydraulic fill i recalmation is executed by transporting the mixture of water -soil particles into a relcaimed land through dredging pipes, then the dredged soil particels settle down in thewater orflow over an out flow weir with the water. The amount of the volume reductions of dredged soil is considered the sum of the overall settlement by descication shrinkage and self-weigth consolidation and the loss of soil particles flow over a weir. In the present study, hydrometer analysis was performed with the soil samples obtained bofore and after dredging to estimate the amount of soil particles residual at reclaimed area and the loss of soil particles , then it was suggested the method of determining the loss ratio of dredged soils from the tests results. The hydrometer analysis of in-situ soil samples showed that the loss ratio of dredged soils is lowest at the nearest point to dredge pipe and highest at the nearest point of out flow weir.

  • PDF

Dimming Control of LED Light Using Pulse Frequency Modulation in Visible Light Communication

  • Lee, Seong-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제19권4호
    • /
    • pp.269-275
    • /
    • 2021
  • Light-emitting diodes (LEDs) are modulated using a square wave pulse sequence for flicker prevention and dimming control in visible light communication (VLC). In a VLC transmitter, the high and low bits of the non-return-to-zero (NRZ) data are converted to two square waves of different frequencies, which continue for a finite time defined by the fill ratio in an NRZ bit time. As the average optical power was kept constant and independent of data transmission, the LED was flicker-free. Dimming control is carried out by changing the fill ratio of the square wave in the NRZ bit time. In the experiments, the illumination of the LED light was controlled in the range of approximately 19.2% to 96.2% of the continuous square wave modulated LED light. In the VLC receiver, a high-pass filter combined with a latch circuit was used to recover the transmitted signal while preventing noise interference from adjacent lighting lamps.

차세대 메모리 디바이스Gap-Fill 공정 위한 공간 분할 PE-ALD개발 및 공정 설계 (Development of Space Divided PE-ALD System and Process Design for Gap-Fill Process in Advanced Memory Devices)

  • 이백주;황재순;서동원;최재욱
    • 한국표면공학회지
    • /
    • 제53권3호
    • /
    • pp.124-129
    • /
    • 2020
  • This study is for the development of high temperature ALD SiO2 film process, optimized for gap-fill process in manufacturing memory products, using a space-divided PE-ALD system equipped with an independent control dual plasma system and orbital moving unit. Space divided PE-ALD System has high productivity, and various applications can be applied according to Top Lid Design. But space divided ALD system has a limitation to realize concentric deposition map due to process influence due to disk rotation. In order to solve this problem, we developed an orbit rotation moving unit in which disk and wafer. Also we used Independent dual plasma system to enhance thin film properties. Improve productivity and film density for gap-fill process by having deposition and surface treatment in one cycle. Optimize deposition process for gap-fill patterns with different depths by utilizing our independently controlled dual plasma system to insert N2and/or He plasma during surface treatment, Provide void-free gap-fill process for high aspect ratio gap-fill patterns (up to 50:1) with convex curvature by adjusting deposition and surface treatment recipe in a cycle.

Fill Dam의 기계 전압효과에 관한 연구 (A Study on the Mechanical Compaction of Fill Dam)

  • 윤충섭;김주범
    • 한국농공학회지
    • /
    • 제21권3호
    • /
    • pp.92-103
    • /
    • 1979
  • The compaction of core zone of the fill dam is very important foe increasing of the Strength of soil mass and reduction of permeability of the core. The principal objects of this study are to give the construction criteria of tamping rollers and to find out the relationships between density and permeability of soil after compaction. The results in this study are summarized as follows. 1. The core zone of fill dam should be compacted more than 8 passed because the compaction effects of clayey soil increase sharply in about 8 passes of roller. 2. The coefficient of permeability (K) increases with the thickness of compaction of soil even though the density is same. 3. The effect of compaction increases with the quantity of coarse materials such as coarse sand and gravel. 4. If D values change from 100 percent to 98 percent and from 100 percent to 95 percent, K values become 2 times and 5 times of initial K value respectively. 5. The coefficient of permeability in the field soil is very high comparing with the result of laboratory test at the same 100 percent compaction ratio, but differences between both results decrease with the decrease of compaction ratio. 6. Thickness of soil layer for the compaction should be increased for heavier compaction machine. 7. In order to get the compaction ratio of 98 percent or more, 10 to 12 passes of roller is generally required with the thickness of soil from 20cm to 30cm.

  • PDF

Bulk-fill 복합레진과 전통적 복합레진의 물성비교 (Comparison of the Mechanical Properties between Bulk-fill and Conventional Composites)

  • 노태환;송은주;박소영;표애리;권용훈;김지연;김신;정태성
    • 대한소아치과학회지
    • /
    • 제43권4호
    • /
    • pp.365-373
    • /
    • 2016
  • 치아우식증을 치료할 때 가장 많이 사용되는 수복재료 중 하나는 레진이다. 하지만 레진은 중합수축, 긴 작업시간, 수분 및 오염에 민감하다는 단점들이 존재하고 어린이를 치료할 때 더 두드러진다. 이러한 단점들을 해결하기 위해 bulk filling이 나타나게 되었고, 이를 가능하게 하는 bulk-fill 복합레진이 개발되었다. 본 연구의 목적은 전통적 복합레진과 bulk-fill 복합레진의 물성을 다양한 방법으로 평가 및 비교하기 위함이다. 전통적 복합레진 3 종류(Filtek Z-350 (Z-350), Unifil Flow (UF), Unifil Loflo Plus (UL)), bulk-fill 복합레진 2종류 (SureFil SDR flow (SDR), Tetric N-Ceram bulk fill (TBF))를 사용하였다. 광중합기는 light-emitting diodes를 사용하였고, 한번 중합할 때 20초간 시행하였다. 재료들의 미세경도는 비커스경도기로 측정하였고, 중합도 측정은 Fourier transform infrared spectroscopy을 사용하였다. 중합수축량은 컴퓨터로 제어되는 linometer를 이용하였다. 굴곡강도 및 굴곡계수는 3점 굽힘 시험법으로 측정하였고, 압축강도 및 압축계수와 함께 Universal testing machine을 이용하여 측정하였다. 통계분석은 ANOVA를 사용하였고, Scheffe의 사후검정을 하였다. 미세경도는 상면에서 Z-350이 가장 높은 값을 나타냈고, 하면은 TBF가 높은 값을 나타냈으나 UL은 상하면 모두에서 가장 낮은 값을 보였다. 상면과 하면의 미세경도 값의 비는 SDR, TBF가 높았다. 중합도는 bulk-fill 복합레진과 유동성 복합레진 상하면 모두에서 높게 나타나고, Z-350는 상하면 모두에서 55% 이하로 나타났다. 압축강도는 Z-350이 가장 높았으며 SDR이 낮게 나타났으나 UL과는 통계학적으로 유의하게 차이는 보이지 않았다. 압축계수는 Z-350이 높게 나타났고, UL이 가장 낮았다. 굴곡강도 및 굴곡계수는 Z-350이 가장 높았다. UL은 굴곡강도 및 굴곡계수 모두 가장 낮게 나타났다. UL이 가장 높은 중합수축을 보였고, Z-350이 가장 낮은 중합수축 값을 나타냈다. 유동성 복합레진이 비유동성 복합레진보다 중합 수축 양이 많았다. 결론적으로 bulk-fill 복합레진의 물성은 전통적 복합레진보다 떨어지지만 bulk filling할 때 중요한 상하면의 미세경도비 및 중합도는 높게 나타나 어린이의 치아우식증 수복치료 시 도움이 될 수 있을 것으로 사료된다.