References
- Andros, F. E., 1980, 'Heat Transfer Characteristics of the Two-Phase Closed Thermosyphon(Wickless Heat Pipe) Including Direct Flow Observation,' Ph. D. Thesis, Arizona State University
- Botemps, A., Goubier, C., Marquet, C., Solecki, J. C. and Nardi, C., 1987, 'Performance Limits of a Toluene Loaded Closed Two- Phasa Thermosyphon,' 6th IHPC, Grenoble, pp. 634-644
- Chen, M. M., 1987, 'Heat Transfer Performance of Two-Phase Closed Thermosyphons with Different Lengths,' 6th IHPC, Grenoble, pp. 647-651
- Cho, D. and Kwon, H., 1997, 'A Experimental Study on the Heat Transfer Performance inside inclined Thermosyphon for the Effect of the Ratio of Reynolds Number of Cooling to Hot Water,' Proc. KSME Spring Conf., pp. 405-410
- Clement, B. and Lee, Y., 1981, 'Additional Parameters in Two-Phase Closed Thermosyphon : Effects of Tube Diameter and Wall Thickness,' Int. J. of Heat and Mass Transfer, Vol. 24, No. 9, pp. 1554-1555 https://doi.org/10.1016/0017-9310(81)90223-4
- Cohen, H., Bayley, F. J., 1955, 'Heat Transfer Problem of Liquid Cooled Gas Turbine Blades,' Proc. Inst. Mech. Eng., 169-20, pp. 1063-1080
- Fledman, K. T., Srinivasan, Jr. and R., 1984, 'Investigation of Heat Transfer Limits in Two-Phase Closed Thermosyphon,' 5th IHPC, Tsukuba, pp. 30-35
- Gaugler, R. S., 1944, Heat Transfer Device, US Patent No.2350348, US Patent Application. Dec. 21, 1942
- Hahne, E. and Gross, U., 1981, 'The Influence of the Inclination Angle on the Performance of a Closed Two-Phase Thermosyphon,' 4th IHPC, London, pp. 125-135
- Hashimoto, H., Kaminaga, F. and Matsumura, K., 1999, 'Study on Condensation Heat Transfer Characteristics in a Thermosyphon with Non-Condensable Gas Effect,' 11th IHPC, Vol. 1, pp. 121-126
- Hong, J., Boo, J. and Jung, Y, 1998, 'Experiments on the Thermal Performance of a Thermosyphon in Inner Grooved Copper Tube,' Proc. SAREK Summer Conf., pp. 313-317
- Imura, H., Kusuda, H., Ogata, J. I., Miyaz, T. and Sakamoto, N., 1977, 'Heat Transfer in Two-Phase Closed-Type Thermosyphons,' Trans. of Japan Soc. of Mech. Engrs., pp. 485-493
- Kline, S. J. and McClintock, F. A., 1953, 'Describing Uncertainties in Single-Sample Experiments,' Mechanical Engineering, Vol. 75, pp. 3-8
- Larkin, B. S., 1971, 'A Experimental Study of the Two Phase Thermosyphon Tube,' Trans. Canda. Soc. Mech. Engrg., 14-B6, pp. 1-8
- Lee, Y. and Mital, U., 1972, 'A Two-Phase Closed Thermosyphon,' Int. J. of Heat and Mass Transfer, 15-9, pp. 1695-1707 https://doi.org/10.1016/0017-9310(72)90098-1
- Negishi, K. and Sawards, T., 1983, 'Heat Transfer Performance of an Inclined Two- Phase Closed Thermosyphon,' Int. J. of Heat and Mass Transfer, Vol. 26, No. 8, pp. 1207-1213 https://doi.org/10.1016/S0017-9310(83)80175-6
- Nusselt, W., 1916, 'Die Oberflachenkondensation des Wasserdampfes, Z. Ver. Deut. Ing., 60
- Park, R. J., 1992, 'Two-Phase Closed Thermosyphon with Two-Fluid Mixtures,' M. S. Thesis, Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada
- Peterson, G. P. and Ma, H. B., 1996, 'Experimental Investigation of the Maximum Heat Transport in Triangular Groove,' ASME J. of Heat Transfer, Vol. 35, No. 3, pp. 740-746
- Qi, W. and Lang, Y., 1999, 'Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon Working with a Binary Mixture at Different Incline Angles,' 11th IHPC, Vol. 1, pp. 110-115
- Sterling, C. O. and Tichacek, L. J., 1961, 'Heat Transfer Coefficients for Boiling Mixtures,' Chem. Engrg Sci., 16, pp. 297-337 https://doi.org/10.1016/0009-2509(61)80040-7
- Stre'tsov, A. I., 1975, 'Theoretical and Experimental Investigation of Optimum Filling for Heat Pipes,' Heat Transfer, Soviet Research, Vol. 7, No. 1, pp. 23-27
- Tu, C., Xie, G., Hu, C., Gao, Z. and Hong, R., 1984, 'The Two Phase Closed Thermosyphon : an Experimental Study with Flow Pattern and Optimum Fill Charge,' China-U. S. Seminar on Two-flows and Heat Transfer, Sian, pp. 395-405
- Yiwei, M., Wang, J. C. Y., Jifu, L. and Yi, F., 1989, 'Theoretical and Experimental Studies on Condensation Heat Transfer inside Vertical and Inclined Thermosyphons,' National Heat Transfer Conference HTD-vol, 108, pp. 111-116