• Title/Summary/Keyword: Field variation

Search Result 2,689, Processing Time 0.027 seconds

Calling song and phonotactic selectivity in the field cricket Teleogryllus emma (Orthoptera: Gryllidae)

  • Jang, Soo-Jin;An, Hyon-Gyong;Jang, Yi-Kweon
    • Journal of Ecology and Environment
    • /
    • v.33 no.4
    • /
    • pp.307-315
    • /
    • 2010
  • Males of the field cricket Teleogryllus emma produce calling songs that are attractive to receptive females. The calling songs of T. emma consist of two components, the long chirp that is composed of up to 12 single pulses, followed by a variable number of short chirps. Based on the analysis of coefficient of variation (CV), temporal characters of the long chirp were less variable than those of the short chirps in male calling songs. To test for phonotactic selectivity of females, we conducted a single-stimulus playback experiment in which five stimuli (standard, long chirp only, long chirp augmented, short chirps only, and short chirps augmented) were used. The standard stimulus included both long and short chirps whose characteristics were derived from the calling songs of field populations. Results of the playback experiment showed that female crickets oriented more frequently toward the stimuli that included the long chirp (standard, long chirp only, and long chirp augmented stimuli) than toward the stimuli lacking the long chirp (short chirps only and short chirps augmented stimuli), indicating that the long chirp in the calling songs was required to elicit positive phonotaxis in the female crickets. The result of CV analysis of the male calling songs and the findings of the female phonotaxis experiment suggested that the long chirp of calling songs may play a role in species recognition in T. emma.

Characteristics of Tropical Cyclone Activity Influenced by Decadal Variability of SST (해수면 온도의 10년 주기 변동에 영향을 받는 Tropical Cyclone의 특징)

  • Kim, Dong-Hyeok;Kang, In-Sik
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.485-492
    • /
    • 2008
  • This study confirms that a decadal variation of the SST (Sea Surface Temperature) in the WNP (Western North Pacific) has an influence on the genesis and passage ofa Tropical Cyclone. The decadal mode was obtained by calculating the SST anomaly on the domain $150^{\circ}E-190^{\circ}E$, and $5^{\circ}S-5^{\circ}N$. Such decadal variation was subsequently analyzed to confirm that it is a dominant mode in central Pacific region. Next, after classifying the years into relatively positive years and relatively negative years, the characteristics of Tropical Cyclone in each year, such as a genesis and passage frequency, were investigated. Compared to the relatively negative years, during the relatively positive years, the location of Tropical Cyclone genesis was biased toward South-Eastern region, while the characteristics of the cyclone were more distinct during late season of the year trom September to December than in mid season from June to August. Examining the movement passage through the observation of passage fiequency, there was a significant difference between positive year and negative year in their passages at a 90% confidence level. Moreover, the number of Tropical Cyclone, maximum wind, and life time also showed higher values in positive years than in negative years. These features were confirmed by examining the 850hPa cyclonic flow field, vorticity field, and vertical wind shear field, all of which contribute to the genesis of a Tropical Cyclone.

Variation of Physical Characteristic of Tidal Flat's Environment by Water Level Change (수위변동에 따른 갯벌의 물리적 환경특성의 변화)

  • Park, Jong-Hwa
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.2 no.3
    • /
    • pp.1-9
    • /
    • 1999
  • This paper described the results of the characteristics of the near-bottom flow and field analysis of the tidal flats sediment. It was the aim of this paper to grasp current flow of tidal flat's environment and influence factor for environmental change forecast of tidal flats. Field measurement of water velocity, water elevation, bed materials test, and temperature distribution of tidal flat were conducted. Thereafter, current flow, turbidity and temperature distribution of tidal flat sediment have been discussed. The field research results showed that the fluctuating velocity near the seabed before and after its appearance at low tide was strongly affected by the wind wave. The resuspension of the sea-bottom sediment took place with great intensity before and after the appearance of the seabed at low tide. Both the sea water level and the weather condition were a significant influential factors. Such as, temperature and turbidity just on the surface and the shallow layer of seabed sediments were varied largely with time and weather conditions, but that its deeper layers was almost constant. Temperature on the seabed sediments was strongly influenced by irradiance and water depth. The temperature variation of the tidal flat and the variation characteristics of the current flow and turbidity depend greatly on the inhabiting environment of the tidal flat benthic organism.

  • PDF

A Study on the Variation of Magnetic Field Intensity and Short Current by Coating Material of Spray in AF Track Circuits (AF궤도회로에서 코팅재에 의한 자계의 세기 및 단락전류 변화에 대한 연구)

  • Kim, Min-Seok;Oh, Sea-Hwa;Park, Yong-Gul;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.552-559
    • /
    • 2011
  • There is a method for offering continuous information by AF track circuits. Magnetic fields are formed by current through rails in the AF track circuit systems. So, the continuous information is received by the magnetic fields on a on-board antenna. Coating materials of spray on rails are researched to decrease defects such as head check, shelling, corrugation, squats and so on in Germany. Currently, a coating method of rail construction is proposed by using the ceramics in Korea. When deciding physical characteristic of the coating material of spray, researches are required about variation of flux density and resistivity by using the coating material of spray. In case that the flux density is much lower than existing value, the information for train control is not transmitted to the on-board antenna. In this paper, inductance on rails is calculated and a model is presented about variation of the magnetic field intensity and resistivity in the AF track circuit. Standard permeability of the coating material of spray is proposed. Also, standard resistivity of the coating material of spray is presented by analyzing short current.

An Experimental Study on the Characteristics of the High Temperature Superconductor as an Application of the Repulsive Type Magnetic Bearing (반발식 자기 베어링의 응용으로서 고온 초전도체의 특성에 관한 실험적 연구)

  • 유제환;임윤철
    • Tribology and Lubricants
    • /
    • v.13 no.2
    • /
    • pp.52-59
    • /
    • 1997
  • An experimental study is presented for the characteristics of the high temperature superconductor as an application of the repulsive type magnetic bearing. A ring shaped YBCO type superconductor and Neodium permanent magnets are employed for the experiment. For the case of field cooling, superconductor shows strong repulsive force, which is due to the Meissner effect, as the gap between the superconductor and the magnet gets closer. The repulsive force variation with respect to the gap change shows hysterisis characteristics. The area of the loop of the hysterisis curve represents the dissipation of energy, which reveals that the magnetic bearing with superconductor has large damping. The effect of the initial gap and the magnetic flux density on the repulsive force is analyzed experimentally and the static stiffness variation is calculated from the measured repulsive force variation. The relative sliding velocity between the superconductor and the magnet has little effect on the repulsive force which is quite different from the usual sliding element bearing. As the initial gap for the field cooling becomes larger, the maximum repulsive force at the minimum gap increases and approaches to the value for the case of zero field cooling.

Calculation of AC Losses by Perpendicular Magnetic Field (수직방향 자장에 의한 교류손실 계산)

  • 이승욱;심정욱;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.172-175
    • /
    • 2001
  • AC loss which is generated in an HTS wire varies with the direction of the external magnetic field. This paper calculates the AC loss in an HTS tape, where effects of the perpendicular direction of the magnetic field are considered. Brandt equation is used to calculate the loss by perpendicular magnetic field. In the calculation, current densities are varied along the variation of the magnitude of the external magnetic field. Results of calculation are compared with those of the conventional method.

  • PDF

SEASONAL AND UNIVERSAL TIME VARIATIONS OF THE AU, AL AND DST INDICES

  • AHN BYUNG-HO;MOON GA-HEE
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.spc1
    • /
    • pp.93-99
    • /
    • 2003
  • Various attempts have been made to explain the: pronounced seasonal and universal time (UT) variations of geomagnetic indices. As one of such attempts, we analyze the hourly-averaged auroral electroject indices obtained during the past 20 years. The AU and AL indices maximize during summer and equinoctial months, respectively. By normalizing the contribution of the solar conductivity enhancement to the AU index, or to the eastward electrojet, it is found that the AU also follows the same semiannual variation pattern of the AL index, suggesting that the electric field is the main modulator of the semiannual magnetic variation. The fact that the variation pattern of the yearly-mean AU index follows the mirror image of the AL index provides another indication that the electric field is the main modulator of magnetic disturbance. The pronounced UT variations of the auroral electrojet indices are also noted. To determine the magnetic activity dependence, the probability of recording a given activity level of AU and AL during each UT is examined. The UT variation of the AL index, thus obtained, shows a maximum at around 1200-1800 UT and a minimum around 0000-0800 UT particularly during winter. It is closely associated with the rotation of the geomagnetic pole around the rotational axis, which results in the change of the solar-originated ionospheric conductivity distribution over the polar region. On the other hand the UT variation is prominent during disturbed periods, indicating that the latitudinal mismatch between the AE stations and the auroral electrojet belt is responsible for it. Although not as prominent as the AL index, the probability distribution of the AU also shows two UT peaks. We confirm that the Dst index shows more prominent seasonal variation than the AE indices. However, the UT variation of the Dst index is only noticeable during the main phase of a magnetic storm. It is a combined result of the uneven distribution of the Dst stations and frequent developments of the partial ring current and substorm wedge current preferentially during the main phase.

Experiment Research for Wax Appearance Temperature Determination of Opaque Oil (석유생산 시 유동안정성 확보를 위한 불투명 오일의 왁스생성온도 결정 연구)

  • Kang, Pan-Sang;Hwang, Soon-Hye;Son, Bi-Ryong;Lim, Jong-Se
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2015
  • Wax deposition hinders oil flow assurance. Huge amount of money and time were required for mitigation of wax deposition in the oil field. For prediction and mitigation of wax deposition problem, Wax Appearance Temperature(WAT), which is the temperature at which the first wax crystals start to form, needs to be measured in advance. There is a standard method which is optical way to measure the WAT of transparent oil. However, standard method cannot be applied to opaque oil which is common produced oil in the field. In this study, WAT of three transparent oil samples were measured using heat flux variation analysis, viscosity variation analysis and density variation analysis, and compared with WAT measured by standard method. As a result, WAT measured by density variation analysis is the more reliable than heat flux variation analysis and viscosity variation analysis. WAT of two opaque oils were measured using density variation analysis.

Study on Influence of Rotor Temperature Variation on the Performance of Maximum Torque Per Amp Control Strategy (단위 전류당 최대 토크 제어기 성능에 미치는 로터 온도 변화의 영향에 대한 연구)

  • Kwon, Chun-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3110-3114
    • /
    • 2009
  • Rotor temperature variation is a significant issue in the design of induction motor controls. In the literature, numerous studies have mentioned significant performance degradation due to rotor temperature variation unless it is taken into account. However, those studies have mainly focused on field-oriented control in terms of tracking performance. There was little research about the influence of rotor temperature variation on performance particularly in the case of optimal controls such as maximum torque per amp (MTPA) control strategy. This work investigates how to affect the performance of maximum torque per amp (MTPA) control strategy as rotor temperature varies in time. To this end, investigation was carried out in two ways to see whether the objective of MTPA control strategy is achieved regardless of rotor temperature variation. It is to produce a desired torque with the minimum possible stator current at the same time. Laboratory experiment shows that tracking performance and maximum torque per amp condition is significantly affected by rotor temperature variation as rotor temperature varies, thus ending up with performance degradation of MTPA control.