• Title/Summary/Keyword: Field treatment

Search Result 4,499, Processing Time 0.034 seconds

Improved Field Emission by Liquid Elastomer Modification of Screen-Printed CNT Film Morphology

  • Lee, Hyeon-Jae;Lee, Yang-Doo;Cho, Woo-Sung;Kim, Jai-Kyeong;Lee, Yun-Hi;Hwang, Sung-Woo;Ju, Byeong-Kwon
    • Journal of Information Display
    • /
    • 제7권2호
    • /
    • pp.16-21
    • /
    • 2006
  • The effect of improvement on the surface morphology of screen-printed carbon nanotube (CND) films was studied by using the optically clear poly-dimethylsiloxane (PDMS) elastomer for surface treatment. After the PDMS activation treatment was applied to the diode-type CNT cathode, the entangled carbon nanotube (CNT) bundles were broken up into individual free standing nanotubes to remarkably improve the field-emission characteristics over the as-deposited CNT film. Also, the cathode film morphology of a top gated triode-type structure can be treated by using the proposed surface treatment technique, which is a low-cost process, simple process. The relative uniform emission image showed high brightness with a high anode current. This result shows the possibility of using this technique for surface treatment of large-size field emission displays (FEDs) in the future.

신경조직 재활치료를 위한Crossing High-Amplitude Magneto-Therapy 자기신경 시스템의 설계 및 제작에 관한 연구 (Research about design and manufacture of Crossing High-Amplitude Magneto-Therapy own nerve system for nervous tissue rehalibitation treatment)

  • 김휘영
    • 한국컴퓨터산업학회논문지
    • /
    • 제7권3호
    • /
    • pp.263-270
    • /
    • 2006
  • 자계신경 자극치료는 다른 분야에 비해 많이 낙후된 실정이다. 특히, 자기장(MF)의 성공적인 의료도입이 Avicenna의 연구에서 오래전에 언급되었고, 최근에 의학 magnetology 발달의 시대로 생각될 수 있다. 이러한 발달은 공학자와 생물학자 그리고 임상의의 접합부분 노력을 통하여 이루어지고 있으며, 새로운 장비들과 BT기술은 꾸준히 발전되고 있다. 자계신경 자극치료분야는 CMF, VMF, PMF분야 등이 대표적이나 본 연구에서는 HPMT기술인 장파 high-amplitude(전통적인 magneto-therapy의 크게 대단한 강렬) 짧은시간 치료용 시스템을 각 기능별로 설계하고 제작하여 특성을 비교분석 하였다.

  • PDF

방사선치료에 있어서 Multileaf Collimator의 원리와 그 응용 (Principles and Applications in Multileaf Collimator for Radiation Therapy)

  • 정갑수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.24-28
    • /
    • 1998
  • A conventional treatment machine shapes x-ray fields by a set of dense metal collimators(jaws) built into the machine. These collimators are positioned by the therapist using hand controls in the treatment room, and usually remain stationary during treatment. The collimator jaws of treatment machines produce rectangular beams. Conventional beam shaping is accomplished through the use of a combination of these collimator jaws and secondary custom beam blocks attached to the accelerator beyond the collimator Jaws. The jaw positions for a particular field can be retrieved from a computer. One application of this increased capability is replacement of beam blocks for field-shaping with the MLC. There are three basic applications of the MLC. The first application is to replace conventional blocking. A second function of the MLC is related to conformal therapy, adjusting the field shape to match the beam's eye view projection of a planning target volume during treatment. The third application is the use of the MLC to achieve beam intensity modulation. The aim of this paper is to provide basic principle and to state fundamental concepts needed to implement the use of a multileaf collimator in the conventional clinical setting. The use of MLC field shaping is likely to save time and to incur a lower operating cost when compared to the use of beam blocks.

  • PDF

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

  • Fiser, Ondrej;Merunka, Ilja;Vrba, Jan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1744-1753
    • /
    • 2016
  • The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the treatment planning based on the optimization process made through the SEMCAD X software is added to show the steering possibilities of SAR and thereby temperature distribution. Using treatment planning software, we proved that the SAR and temperature distribution can be effectively controlled (by amplitude and phase changing) improving the SAR and temperature target coverage approximately by 20 %. For the proposed applicator system analysis and quantitative evaluation of two parameters 25 % iso-SAR and $41^{\circ}C$ iso-temperature contours in the treatment area with the respect to sensitive structures in treatment area were defined. To verify our simulation results, the real measurement of reflectivity coefficient as well as the temperature distribution in a homogenous phantom were performed.

Pulsed Electric Field Effects to Reduce the Level of Campylobacter spp. in Scalder and Chiller Water during Broiler Chicken Processing

  • Shin, Dae-Keun;Martin, Bradely C.;Sanchez-Plata, Marcos X.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제24권9호
    • /
    • pp.1314-1317
    • /
    • 2011
  • To evaluate the effects of pulsed electric field (PEF) application on scalder and chiller water on Campylobacter contamination, four different treatments under three different water conditions including hard scalder water ($55^{\circ}C$), soft scalder water ($45^{\circ}C$) and chiller water, were applied as follows: i) a control treatment with no salt and no electric treatment, ii) a PEF only treatment, iii) a PEF treatment with 0.5% salt water, and iv) a PEF treatment with 1% salt water treatment. The use of PEF in hard scalding water showed an effect of reducing Campylobacter when compared to the control during the 200 s timeframe. With the addition of salt, the intervention caused at least 5.81 log CFU/ml reduction of Campylobacter counts after 200 s of PEF exposure. Similar effects were observed under soft scalding conditions. Campylobacter reductions were evident under chilling conditions with up to 2.00 log for PEF only, 5.77 log for PEF+0.5% salt and 2.69 log for PEF+1% salt treatment in water. Therefore, the current PEF setting for the scalder and chiller water can be successfully used to reduce pathogenic loads of Campylobacter on broiler chicken carcasses, and further research may be necessary to apply it in the poultry processing industry.

탄소나노튜브 캐소드에서 표면처리 방법이 전계방출 특성에 미치는 영향 (Effects of Surface Treatment on Field Emission Properties for Carbon Nanotube Cathodes)

  • 성명석;오정섭;이지언;정승진;김태식;조영래
    • 한국재료학회지
    • /
    • 제16권1호
    • /
    • pp.37-43
    • /
    • 2006
  • Carbon nanotube cathodes (CNT cathodes) were fabricated by a screen printing method using multi-walled carbon nanotubes. The effects of surface treatment on CNT cathodes were investigated for use in high efficiency field emission displays. The optimum surface treatment for a CNT cathode is dependent on a relative bonding force of CNT films on the cathode after a heat treatment. Because of the high bonding force used in the Liquid method, this method is recommended for CNT cathodes which are heat-treated at $390^{\circ}C$ in a $N_2$ atmosphere. The Rolling method is applicable for CNT cathodes fabricated at $350^{\circ}C$ in an atmosphere of air. The results of this study provide basic criteria for the selection of an appropriate surface treatment for large area CNT cathodes.

방사선 치료 시 조사야 내에 위치할 수 있는 이물질이 체표선량에 미치는 영향 (Effect of skin dose by materials located in treatment field)

  • 홍채선;김경태;주상규;김종식;박영환
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.59-64
    • /
    • 2002
  • Purpose : In radiotherapy, various materials are used to located in treatment field unintentionally. It increases the dose delivered to the skin by interactions of the X-ray within the materials and occurs unwanted skin reaction.(due to the dose build-up effect) This aim of the this study is to measure the increase in skin dose when 13 materials are located in treatment field. Methods : Photon beam measurements were made using an plane-parallel chamber (Markus, PTW-Freiburg) in a polystyrene phantom. skin dose were measured using various overlaying 13 materials. a fixed geometry of a $10{\times}10cm$ field, a SSD=100cm and photon energy 4MV on Varian CLINAC 600C accelerator were used for all measurements. Results : There is an increase in skin dose for all materials($16.4{\sim}160.1\%$). As a percentage of maximum dose, the lowest skin dose were measured for the underwear with silk($43.2\%$) and the highest were measured for the 100m1 fluid-bag($96.6\%$) Conclusion : There is a significant increase in skin dose with 13 materials in the treatment field. a significant increase in skin dose can occur which could produce unwanted skin reaction. considerations for placement of 13 materials to be outside the treatment field whenever possible should be used to keep skin dose to a minimum level.

  • PDF

The Extent of Awareness and Knowledge Regarding Temporomandibular Disorder among Korean College Students

  • Park, Hye Sook
    • Journal of Oral Medicine and Pain
    • /
    • 제47권1호
    • /
    • pp.38-51
    • /
    • 2022
  • Purpose: The purpose of this study was to analyze the extent of awareness and understanding of college students on temporomandibular disorder (TMD) and to search for avenues for raising public awareness and improving knowledge about TMD. Methods: One thousand and one hundred and twenty one college students in Gyeonggi-do completed a questionnaire related to awareness, experience and knowledge of TMD and collected data were analyzed by Pearson's chi-squared test. Results: Women were more significantly aware of the terms, 'TMD' (p<0.001) and 'jaw joint disease' (p<0.001) than men. Third graders were more significantly aware of the terms, 'TMD' (p<0.001) and 'jaw joint disease' (p<0.001) than any other graders. Third graders the most frequently chose to visit department of dentistry for the treatment of TMD among three graders (p<0.001). Women more frequently chose to visit department of dentistry for the treatment of TMD than men (p<0.001). Health field subjects were more significantly aware of the terms, 'TMD' (p<0.001) and 'jaw joint disease' (p<0.001) than non health field subjects. Having more frequently visited department of dentistry for the treatment of TMD than non health field subjects (p<0.001), health field subjects more frequently chose to visit department of dentistry for the treatment of TMD in the future (p<0.001). Conclusions: The level of awareness and knowledge of TMD was higher in women college students, health field subjects and third graders than men college students, non health field subjects and the rest of two graders, respectively. The higher the level of experience and education of the subject, the more aware the subject was of TMD. Therefore publicity activities and education through various routes are required to raise public awareness and knowledge of TMD. In addition, it is necessary to inform general public of the dentistry specialized for the accurate diagnosis and standardized treatment of TMD.

유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가 (Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques)

  • 반태준;전수동;곽정원;백금문
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.183-188
    • /
    • 2012
  • 목 적: 암치료 기술의 발전으로 환자의 생존기간이 길어짐에 따라 치료 이후 삶의 질을 증진하고 치료 방법에 의한 부작용을 줄이는 노력에 관심이 집중되고 있다. 본 연구는 유방암 접선조사 치료에서 치료방법 차이가 반대쪽 유방 산란 선량에 미치는 영향을 분석하고자 하였다. 대상 및 방법: 본원에서 제작한 유방 모형 팬텀의 전산화 단층 영상을 이용하여 이클립스 10.0 (Eclipse 10.0, Varian, USA) 치료계획 시스템을 사용하여 $30^{\circ}$ wedge plan, $15^{\circ}$ wedge plan, $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, Non-wedge plan, FIF(Field in Field) plan을 수립하였다. 각 치료계획은 선형가속기 CL-6EX (VARIAN, USA)를 이용하여 400 cGy씩 조사하였고 팬텀의 중심점으로부터 횡축방향으로 1 cm, 3 cm, 5 cm, 9 cm 씩 이동한 지점의 1 cm 깊이에서 전리조(FC 65G, IBA)를 이용하여 내측접선(Medial tangential) 조사와 외측접선(Lateral tangential) 조사에서 발생하는 산란선량을 각각 측정하고 비교 분석하였다. 결 과: 반대쪽 유방 산란 선량을 평가해보았을 때 $30^{\circ}$ wedge plan, $15^{\circ}$ wedge plan, $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, Non-wedge plan, FiF (Field in Field) plan에서 처방선량에 대해 각각 6.55%, 4.72%, 2.79%, 2.33%, 1.87%로 나타났다. 내측접선조사와 외측접선 조사로 나누어 보았을 때 내측접선 조사 측정값은 각각 4.94%, 3.33%, 1.55%, 1.17%, 0.77%로 나타났고 외측접선 조사는 각각 1.61%, 1.40%, 1.24%, 1.16%, 1.10%의 산란 선량이 측정되었다. 결 론: 유방암 접선 조사 치료방법 중 반대쪽 유방에 가장 적은 산란 선량이 발생하는 방법은 FiF plan으로 이때 발생한 산란선량은 팬텀 내에서 기인한 선량이 주로 작용하는 것으로 판단되었다. 가장 많은 산란 선량이 발생하는 치료방법은 $30^{\circ}$ wedge plan이었고 쐐기필터를 비롯한 치료 장비에서 기인한 선량은 3.3%로 평가되었다. 치료계획 시스템은 처방선량에 대해 상대적으로 낮은 산란 선량 영역은 정확성이 떨어지는 것으로 나타났다. 치료 조사야 밖으로 발생하는 산란 선량은 처방 선량에 비해 그 양이 적지만 2차 암 발생 확률과 관련이 있다는 점에서 간과할 수 없는 부분이며 방사선 치료를 결정하는데 있어 고려되어야 할 부분으로 사료된다.

  • PDF

동측 반맹을 호소하는 후두엽-두정엽 뇌출혈 환자에 대한 복합 한의치험 1례 (A Case of homonymous Hemianopia after Occipital-Parietal Lobe Hemorrhage Treated with Combined Korean Medical Treatment)

  • 정성훈;배인후;김근영;조기호;문상관;정우상;권승원;이한결
    • 대한중풍순환신경학회지
    • /
    • 제23권1호
    • /
    • pp.65-72
    • /
    • 2022
  • ■Background Overall prevalence of visual field loss after stroke was estimated at 31%, ranged from 5.5- 57%. Among them, homonymous hemianopia is the most common symptom of post-stroke visual field loss and leads to a decrease in the quality of life and therapeutic effect. However, standard treatment has not been established. ■Case report A 48-year-old male with right side homonymous hemianopia by a left occipital-parietal lobe hemorrhage was treated with Qu-Ji-Du-Huang-Wan, acupuncture and electroacupuncture for 20 days. We used confrontation visual field exam, automated perimetry and visual analog scale for evaluating symptoms. Following treatment, confrontation visual field exam and the subjective discomfort was improved. ■Conclusions The present case report suggests that combined Korean medicine treatment might be an effective treatment of post-stroke homonymous hemianopia. A number of follow up studies should be conducted to clarify the effectiveness of treatment.