• Title/Summary/Keyword: Field correction

Search Result 743, Processing Time 0.032 seconds

Scanning Rayleigh Doppler Lidar for Wind Profiling Based on Non-polarized Beam Splitter Cube Optically Contacted FPI

  • Zheng, Jun;Sun, Dongsong;Chen, Tingdi;Zhao, Ruocan;Han, Yuli;Li, Zimu;Zhou, Anran;Zhang, Nannan
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.195-202
    • /
    • 2018
  • A Scanning Rayleigh Doppler lidar for wind profiling based on a non-polarized beam splitter cube optically contacted FPI is developed for wind measurement from high troposphere to low stratosphere in 5-35 km. Non-polarized beam splitter cube optically contacted to the FPI are used for a stable optical receiver. Zero Doppler shift correction is used to correct for laser or FPI frequency jitter and drift and the timing sequence is designed. Stability of the receiver for Doppler shift discrimination is validated by measuring the transmissions of FPI in different days and analyzed the response functions. The maximal relative wind deviation due to the stability of the optical receiver is about 4.1% and the standard deviation of wind velocity is 1.6% due to the stability. Wind measurement comparison experiments were carried out in Jiuquan ($39.741^{\circ}N$, $98.495^{\circ}E$), Gansu province of China in 2015, showing good agreement with radiosonde result data. Continuous wind field observation was performed from October 16th to November 12th and semi-continuous wind field of 19 nights are presented.

CONSTRAINING THE MAGNETIC FIELD IN THE ACCRETION FLOW OF LOW-LUMINOSITY ACTIVE GALACTIC NUCLEI

  • QIAO, ERLIN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.457-459
    • /
    • 2015
  • Observations show that the accretion flows in low-luminosity active galactic nuclei (LLAGNs) probably have a two-component structure with an inner hot, optically thin, advection dominated accretion flow (ADAF) and an outer truncated cool, optically thick accretion disk. As shown by Taam et al. (2012), within the framework of the disk evaporation model, the truncation radius as a function of mass accretion rate is strongly affected by including the magnetic field. We define the parameter ${\beta}$ as $p_m=B^2/8{\pi}=(1-{\beta})p_{tot}$, (where $p_{tot}=p_{gas}+p_m$, $p_{gas}$ is gas pressure and $p_m$ is magnetic pressure) to describe the strength of the magnetic field in accretion flows. It is found that an increase of the magnetic field (decreasing the value of ${\beta}$) results in a smaller truncation radius for the accretion disk. We calculate the emergent spectrum of an inner ADAF + an outer truncated accretion disk around a supermassive black hole by considering the effects of the magnetic field on the truncation radius of the accretion disk. By comparing with observations, we found that a weaker magnetic field (corresponding to a bigger value of ${\beta}$) is required to match the observed correlation between $L_{2-10keV}/L_{Edd}$ and the bolometric correction $k_{2-10keV}$, which is consistent with the physics of the accretion flow with a low mass accretion rate around a black hole.

A study on the sensor for measuring the transient electric fields (시변성(時變性) 전계(電界) 측정용(測定用) 센서에 관한 연구)

  • Lee, Bok-Hee;Paek, Yong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.318-321
    • /
    • 1991
  • For measuring the transient electromagnetic fields and related quantities created by disconnector operations in GIS, one needs the wide bandwidth sensors with simple transfer functions. This paper describes a new developed electric field sensor to measure the very fast transient electric fields and voltages, and the measuring principle, design and construction of planar electric field sensor are described. A calibration and/or correction technique of the sensor is investigated which enables an accurate determination of the sensor response to the time-changing electric fields. As a consequence, the low voltage calibrations certify that a rise time of 1.7 [ns] is achieved for the planar electric field sensor and a total bandwidth extending from several Hz to 200 MHz for the measuring system which presents the constant division ratio as a function of frequency.

  • PDF

Development of Correction Formulas for KMA AAOS Soil Moisture Observation Data (기상청 농업기상관측망 토양수분 관측자료 보정식 개발)

  • Choi, Sung-Won;Park, Juhan;Kang, Minseok;Kim, Jongho;Sohn, Seungwon;Cho, Sungsik;Chun, Hyenchung;Jung, Ki-Yuol
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.1
    • /
    • pp.13-34
    • /
    • 2022
  • Soil moisture data have been collected at 11 agrometeorological stations operated by The Korea Meteorological Administration (KMA). This study aimed to verify the accuracy of soil moisture data of KMA and develop a correction formula to be applied to improve their quality. The soil of the observation field was sampled to analyze its physical properties that affect soil water content. Soil texture was classified to be sandy loam and loamy sand at most sites. The bulk density of the soil samples was about 1.5 g/cm3 on average. The content of silt and clay was also closely related to bulk density and water holding capacity. The EnviroSCAN model, which was used as a reference sensor, was calibrated using the self-manufactured "reference soil moisture observation system". Comparison between the calibrated reference sensor and the field sensor of KMA was conducted at least three times at each of the 11 sites. Overall, the trend of fluctuations over time in the measured values of the two sensors appeared similar. Still, there were sites where the latter had relatively lower soil moisture values than the former. A linear correction formula was derived for each site and depth using the range and average of the observed data for the given period. This correction formula resulted in an improvement in agreement between sensor values at the Suwon site. In addition, the detailed approach was developed to estimate the correction value for the period in which a correction formula was not calculated. In summary, the correction of soil moisture data at a regular time interval, e.g., twice a year, would be recommended for all observation sites to improve the quality of soil moisture observation data.

Variation in Depth Dose Data between Open and Wedge Fields for 6 MV X-Rays (6MV X선에 있어서 쇄기형 조사야와 개방 조사야 사이의 깊이 선량률의 차이)

  • U, Hong;Ryu, Sam-Uel;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.279-285
    • /
    • 1989
  • Central axis depth dose data for 6 MV X-rays, including tissue maximum ratios, were measured for wedge fields according to Tatcher's equation. In wedge fields, the differences in magnitude which increased with depth, field size, and wedge thickness increased when compared with the corresponding open field data. However, phantom scatter correction factors for wedge fields differed less than $1\%$ from the corresponding open field factors. The differences in central axis percent depth dose between two types of fields indicated beam hardening by the wedge filter The deviation of percent depth doses and scatter correction factors between the effective wedge field and the nominal wedge field at same angle was negligible. The differences were less than $3.20\%$ between the nominal or effective wedge fields and the open fields for percent depth doses to the depth 7cm in $6cm{\times}6cm$ field. For larger $(10cm{\times}10cm)$ field size, however, the deviation of percnet depth doses between the nominal or effective wedge fields and the open fields were greater-dosimetric errors were $3.56\%$ at depth 7cm and nearly $5.30\%$ at 12cm. We suggest that the percent depth doses of individual wedge and wedge transmission factors should be considered for the dose calculation or monitor setting in the treatment of deep seated tumor.

  • PDF

Parametric Images of Standardized Uptake Values using P-18-FDG Attenuation Corrected Whole Body PET (F-18-FDG감쇠보정 전신 PET을 이용한 표준섭취계수 추정과 매개변수 영상의 구성)

  • Kim, Kyeong-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Yong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.560-569
    • /
    • 1996
  • Background and Purpose : Standardized uptake value(SUV) has been used as a quantitative index for differentiating benign and malignant tumors with F-18-FDG PET In this study, we produced whole body parametric images of SUV(WBPIS) by body weight normalization, and validated the values by comparison with SUV's calculated with regional scans. Subjects and Methods : Whole body scans were followed by regional scans sequentially on 23 patients. In whole body study, transmission and emission scans were acquired for 2 minutes and 6 minutes for each bed position, respectively. In regional study, transmission and emission scans were acquired for 20 minutes. Measured and segmented/ smoothed attenuation correction were applied using these 2 min transmission scans in whole body studies. The effects of attenuation correction on SUVs were evaluated quantitatively using F-18 filled cylindrical phantom. The mean and peak SUVs obtained from WBPIS were compared with SUVs of the regional scans. Results : In phantom studies, with any method of attenuation correction using regional or whole body studies of phantom, SUVs were nearly consistent. In whole body scan, SUV obtained using measured attenuation correction method was a little higher than SUV of regional scan. SUV obtained using segmented/smoothed attenuation correction method was a little lower. In patient studies, WBPIS using segmented/smoothed attenuation correction method was much smoother and more readable. SUVs of WBPIS obtained with both methods of attenuation correction were well correlated with SUVs of regional scans(r=0.9). SUVs of WBPIS with measured attenuation correction method were 5% lower than SUVs of regional scans. SUVs of WBPIS with segmented/smoothed attenuation correction method were 10% lower than SUVs of regional scans. The differences of SUVs of WBPIS by the two attenuation correction methods were relatively small compared with the possible differences derived from biological characteristics of tumors. Conclusion : We concluded that WBPIS could be useful in the quantification of tumor as well as in localization of whole body lesions, which were often outside the field of view in regional scan. WBPIS made using segmented/smoothed attenuation correction method could be used in clinical routines and SUVs from attenuation corrected F-18-FDG PET could be used interchangeably with SUVs of regional studies.

  • PDF

Correction of the Sea Effect in the Magnetotelluric (MT) Data Using an Iterative Tensor Stripping During Inversion (MT 자료 역산과정에서 반복적인 Tensor Stripping을 통한 해양효과 보정)

  • Yang, Jun-Mo;Lee, Chun-Ki;Yoo, Hai-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.286-301
    • /
    • 2008
  • When magnetotelluric (MT) data are obtained in vicinity of the coast, the sea can distort observed MT responses, especially those of deep part of subsurface. We introduce an iterative method to correct the sea effect, based on the previous topographic correction method which removes the distortions due to topographic changes in seafloor MT data. The method first corrects the sea effect in observed MT impedance, and then inverts corrected responses in a model space without the sea. Due to mutual coupling between sea and subsurface structure, the correction and inversion steps are iterated until changes in each result become negligible. The method is validated for 1-D and 2-D structure using synthetic MT data produced by 3-D forward modeling including surrounding seas. In all cases, the method closely recovers the given structure after a few iterations. To test the applicability of the proposed method to field data, we generate synthetic MT data for the Jeju Island whose 1-D conductivity structure is well known, using 3-D forward modeling. The distortions due to the surrounding sea start to appear below the frequency about 1 Hz, and are relatively severe in the electrical field perpendicular to the coastline because of the location of the observation sites. The proposed method successfully eliminates the sea effect after three iterations, and both 1-D and 2-D inversion of corrected responses closely recover the given subsurface structure of the Jeju Island model.

Regression Analysis of the Log-Normally Distributed Data and Mean Field Bias Correction of Radar Rainfall (대수정규분포를 따르는 자료의 회귀분석과 레이더 강우의 편의 보정)

  • Yoo, Chul Sang;Park, Cheol Soon;Yoon, Jung Soo;Ha, Eun Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5B
    • /
    • pp.431-438
    • /
    • 2011
  • This study investigated the problem of mean-field bias correction under the assumption that the radar and rain gauge rainfall data follow the log-normal distribution. Regression curves for the average, median and mode of the radar and rain gauge rainfall were derived and evaluated for their usefulness. Additionally, these regression curves were compared with those derived under the assumption that the radar and rain gauge data follow the normal distribution. This study investigated the regression results for the Typhoon Meami occurred in 2003 as an example. As results, three regression lines with the radar rainfall as the independent variable were found to underestimate the rainfall, while those with the rain gauge rainfall as the independent variable to overestimate. Among three types of regression curves considered, the result for the average was most appropriate. However this case was found to be inferior to the regression line passing the origin under the assumption of the normal distribution with the rain gauge rainfall as its independent variable. So it was hard to conclude that the consideration of the log-normality on the correction of radar rainfall is beneficial.

Characteristics in Height Determination considering Gravity Field (동력장을 고려한 높이결정의 특성에 관한 연구)

  • 유복모;양인태;손덕재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.5 no.1
    • /
    • pp.32-42
    • /
    • 1987
  • Global change and local fluctuation of earth's gravity field play important roles in accurate vertical positioning as well as in accurate horizontal positioning. Regarding the impotance, in this study, the concept of gravity potential theory connected with the influence of gravity field and every kind of height were discussed. Various kind of heights using the observed gravity and leveling data were computed and analysed to study the influence of earth's gravity field in accurate vertical positioning. Taking the route from Busan to Kyongju and investigating the ratios ($\Delta$H/dH) of height defferences (dH) between calculated heights considering gravity field and leveling height to relative heights (dH) between adjacent stations, we get the result that the values by correction formula increase linearly according to latitude, and the values by gravity potential ere strongly influenced by pseudo topography.

  • PDF

Development of Auto-Tuning Geomagnetic Compass (자동 자기 왜곡보정 방위센서 개발)

  • Kim, Sang-Cheol;Lee, Yong-Beom;Han, Kil-Su;Im, Dong-Hyeok;Choi, Hong-Gi;Park, Woo-Pung;Lee, Woon-Yong
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.58-62
    • /
    • 2008
  • The need for position information in agriculture is gradually increasing for precise control farm vehicle and effective manage farm land. Though geomagnetic sensor has a lot of merits in estimating heading angle of vehicle because of low costs and sensing ability of magnetic north, it is easy that sensor outputs are distorted in electro magnetic field environment. This study was conducted to develop geomagnetic compass which could be available in measuring relative position from reference point correcting output distorted by external electro magnetic field in a small scale field. Magnetic inducing sensor (PNI's Vector2X) which wound enamel coated copper coil on ferrite core in order to measure and correct earth magnetic field. Magnetic azimuth was corrected using the algorithm which estimated amount of magnetic distortion from the difference between each outputs of magnetic sensors that located on the cross shaped base. Developed auto-tuning magnetic sensor was showed less then 5% as bearing accuracy in the strong magnetic field.