• 제목/요약/키워드: Field Tests

검색결과 3,551건 처리시간 0.252초

Susceptibility to Calonectria ilicicola in Soybean Grown in Greenhouse and Field

  • Kim, K. D.;Russin, J. S.;Snow, J. P.
    • 한국작물학회지
    • /
    • 제43권4호
    • /
    • pp.239-244
    • /
    • 1998
  • Susceptibility of soybean cultivars to Calonectria illicicola was evaluated in a greenhouse by inoculating seedlings with mycelium in agar discs placed on the stems at the soil line. A range of responses was detected among cultivars following inoculation with a virulent isolate of C.ilicicola. Rankings of cultivars between greenhouse tests 1 and 2 were similar for disease severity and areas under the disease progress curves (AUDPC). In addition, rankings of cultivars for Final disease severity were highly correlated with AUDPC in test 1 ($r_s$ =0.88, t =5.48, p<0.001), test 2 ($r_s$ =0.99, t =22.10, p<0.001), and when tests were combined ($r_s$=0.89, t=5.82, p<0. 001). Final disease severity and AUDPC consistently identified Asgrow 7986, Braxton, Cajun, and Forrest as soybean cultivars least susceptible to red crown rot. In 1993 and 1994 field tests, a range in disease susceptibility was observed for tested cultivars but none was completely resistant. Soybean cultivars Braxton, Cajun, and Forrest, which were least susceptible to red crown rot in greenhouse tests, also ranked among cultivars with the lowest disease incidence and AUDPC in field tests. Comparisons .between rankings of the eight cultivars common to greenhouse and field tests showed a correlation between final disease severity from combined greenhouse tests and both final disease incidence ($r_s$=0.63, t =1.99, p<0.1) and AUDPC ($r_s$=0.60, t =1.82, p < 0.2) from the combined field tests. However, AUDPC from greenhouse tests did not correlate with either final disease incidence or AUDPC from field tests. The green-house screening method provided consistent results between greenhouse and field tests and successfully identified the least susceptible cultivars Braxton, Cajun, and Forrest.

  • PDF

연약지반에 대한 현장시험 적용에 관한 연구 (A STUDY ON THE APPLICATION OF FIELD TESTS TO WEAK GROUND)

  • 이승래;정한중;김준석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 가을학술발표회 논문집
    • /
    • pp.145-148
    • /
    • 1992
  • This paper reports the application of field tests to weak ground. In this study, field and laboratory tests were performed in the west seashore of KOREA(Ildo, Sore, Kunsan, Youngam). Applied tests are standard penetration test, cone penetration test, dilatometer test, field vane test, unconsolidated undrained test, oedometer test and other fundametal material properties tests. The results of in-situ test are used to estimate soil types and undrained shear strengths of five clay local deposits. SPT results showed low reliability and FVT war also demonstrated the best field test to weak clayey deposits.

  • PDF

입자결합모델을 이용한 동적콘관입시험(DCPT)의 수치해석 모델링에 관한 연구 (A Study on Numerical Modeling of Dynamic CPT using Particle Flow Code)

  • 유광호;이창수;최준성
    • 한국도로학회논문집
    • /
    • 제16권2호
    • /
    • pp.43-52
    • /
    • 2014
  • PURPOSES : To solve problems in current compaction control DCPT(Dynamic Cone Penetrometer Test), highly correlated with various testing methods, simple, and economic is being applied. However, it、s hard to utilize DCPT results due to the few numerical analyses for DCPT have been performed and the lack of data accumulation. Therefore, this study tried to verify the validation of numerical modeling for DCPT by comparing and analyzing the results of numerical analyses with field tests. METHODS: The ground elastic modulus and PR(Penetration Rate) value were estimated by using PFC(Particle Flow Code) 3D program based on the discrete element method. Those values were compared and analyzed with the result of field tests. Also, back analysis was conducted to describe ground elastic modulus of field tests. RESULTS : Relative errors of PR value between the numerical analyses and field tests were calculated to be comparatively low. Also, the relationship between elastic modulus and PR value turned out to be similar. CONCLUSIONS : Numerical modeling of DCPT is considered to be suitable for describing field tests by carrying out numerical analysis using PFC 3D program.

현장실험에 의한 강성 지오그리드의 내시공성 평가 (Installation Damage Assessment of Rigid Geogrid by Field Tests)

  • 조삼덕;오세용;이광우
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.978-985
    • /
    • 2004
  • Geogrid may be damaged during its installation in the filed. The installation damage mainly depends on two factors, which are materials used and construction activities. Materials relate to geogrid and soils, and construction activities are mainly related to installation of geogrid and compaction of soils. This paper describes the results of a series of field tests, which were conducted to assess the installation damage of the various geogrids according to different fill materials. After field installation damage tests, the change in tensile strength of geogrids was determined from wide width tensile tests using both damaged and undamaged specimens.

  • PDF

중금속 오염토양 안정화층 시공을 위한 원위치 교반방식과 혼합포설방식의 효과비교 (Comparison the Effect of In-situ Mixing Method and Mixed Laying Method for Construction of Stabilizing Layer on Heavy Metal Contaminated Soil)

  • 이상무;김진환;윤여준;김윤수;박남서
    • 터널과지하공간
    • /
    • 제25권6호
    • /
    • pp.505-514
    • /
    • 2015
  • 본 연구에서는 기존 오염토양 안정화처리 시공방법의 문제점에 대한 해결을 위하여 개발한 혼합포설방식 안정화장비의 현장 적용성 및 시공성을 현장실증시험 및 실내시험을 통하여 검증하였다. 현장 실증시험을 통하여 안정화장비의 현장 적용성을 확인하였으며, 현장 교반토의 석회석 분포 및 CaO 함량 분석 등의 실내시험을 통하여 기존 오염토양 안정화처리 시공방법에 비해 개발된 안정화장비 시공방법의 안정화제 교반성이 더 우수한 것을 확인하였다.

실측 동적물성을 이용한 기존 사력댐의 동적거동분석 (Dynamic Analysis of Existing Rockfill Dam Using Dynamic Properties by Field Test and Geophysical Exploration)

  • 이종욱;오병현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.306-313
    • /
    • 2005
  • For seismic response analysis of rockfill dam, dynamic material properties, by field test, are needed. Density and elastic wave profiles have to be known to get an information of the material properties of structure. In this study, various field tests are applied to the example of rockfill dam to get an information of dynamic material properties and seismic safety is evaluated by seismic response analysis with the result of field tests.

  • PDF

현장인발시험을 통한 가압 그라우팅 쏘일네일의 변형특성 (Deformation Characteristics of the Pressurized Grouting Soil Nailing Systems from the Field Pull-out Tests)

  • 천병식;박주석;박시삼;정종주;공진영
    • 한국지반환경공학회 논문집
    • /
    • 제9권2호
    • /
    • pp.61-65
    • /
    • 2008
  • 본 연구에서는 PGSN(Pressurized Grouting Soil Nailing) 시스템이라는 가압 그라우팅 쏘일네일링 공법을 고안하였으며, 본 공법의 보강제의 길이변화 및 보강재의 변화 등의 설계인자에 따른 거동변화를 파악해 보기 위해 변위제어방식의 현장인발시험을 수행하였다. 본 연구에서 수행한 9차례의 현장인발시험에서 그라우트 주입비의 변화를 살펴 보기위해 계측을 수행하였으며, 단기거동특성을 평가하기 위해 일반 쏘일네일링 시스템과 비교해 보았다. 가압 그라우트 쏘일네일링 공법의 인발거동 특성을 통해, 중요한 설계인자인 주입압 및 그라우트 주입비 등의 영향을 살펴보았다. 시험 결과 가압효과에 따른 인발변형 특성은 중력식 그라우팅 쏘일네일에 비해 가압 그라우팅 쏘일네일의 경우 유발되는 변위량이 30~36% 정도 감소하였고, 보강재 변화에 따른 인발 특성을 살펴보면 이형철근에 비해 강관의 경우 유발되는 변위량이 31~32% 정도 감소하는 것으로 나타났다.

  • PDF

청감실험방식에 따른 음풍경 평가결과 비교분석 (Comparative analysis of the soundscape evaluation depending on the listening experiment methods)

  • 조아현;한찬훈
    • 한국음향학회지
    • /
    • 제41권3호
    • /
    • pp.287-301
    • /
    • 2022
  • 본 연구의 목적은 현재 음풍경 조사를 위해 사용되는 실험법 중 현장평가와 실험실평가를 비교·분석하는 것이다. 이를 위해 청주시 내 4개 지역에서 현장평가와 실험실평가를 수행하였다. 현장평가에서는 각 측정점을 이용 중이던 65명의 시민이 음풍경 평가에 참여했으며, 실험실평가에서는 20세 이상 건청인 48명이 참여해 녹취한 영상과 소리를 보고 들은 뒤 평가를 진행하였다. 실험실 평가는 현장 경험자와 현장 비경험자로 나누어 실시하였으며, 음원의 청취방법을 달리하여 헤드폰 및 스피커 이용 그룹으로 분류하여 실시하였다. 분석결과, 현장평가와 실험실평가에서 공통적으로 소리의 크기와 불쾌감 사이에 매우 높은 상관관계가 나타났다. 그러나 실험실 평가에서는 시각 및 청각적 정보만으로는 현장의 상황을 정확히 판단할 수 없기 때문에 현장평가와 실험실평가에서 신호음 인식에 대한 차이가 나타났다. 실험실평가에서 헤드폰과 스피커 이용 그룹의 응답결과 중 가장 크게 들리는 신호음의 인지에 차이가 있었다. 또한 현장경험자는 자신이 경험한 기억을 이용하여 신호음을 인지하는 경향이 있는 반면에 현장비경험자는 주 신호음을 인지하지 못하는 경우가 있었다.

Application of Diagnostic Laboratory Tests in the Field of Oral Medicine: A Narrative Review

  • Ji Woon, Park;Yeong-Gwan, Im
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.101-111
    • /
    • 2022
  • The purpose of laboratory tests in the field of oral medicine can be divided into two categories: (1) medical evaluation of patients with systemic diseases that are planning to receive dental care and (2) diagnosis of patients with certain oral diseases. First, laboratory tests are commonly used to evaluate patients with systemic diseases who need dental management. A combination of multiple tests is usually prescribed as a test panel to diagnose and assess a specific disease. Test panels closely related to oral medicine include those for rheumatoid arthritis, connective tissue disease/lupus, liver function, thyroid screening, anemia, and bleeding disorders. Second, laboratory tests are used as auxiliary diagnostic methods for certain oral diseases. They often provide crucial diagnostic information for infectious diseases caused by bacteria, fungi, and viruses that are associated with pathology in the oral and maxillofacial regions. Laboratory tests for infectious diseases are composed of growth-dependent methods, immunologic assays, and molecular biology. As the field develops, further application of laboratory tests, including synovial fluid analysis in temporomandibular joint disorders, salivary diagnostics, and hematologic biomarkers associated with temporomandibular disorders and orofacial pain conditions, is currently under scrutiny for their reliability as diagnostic tools.

현장인발시험을 통한 가압 그라우팅 쏘일네일의 장기 인발거동특성 (Long-term Behaviour Characteristics of Pressurized Grouting Soil Nails from the Field Pull-Out Tests)

  • 박시삼;이훈연;박주석;이홍규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 2005
  • Recently a pressurized grouting soil nail is demanded due to problems beyond of economical and engineering purpose. In this study, a newly modified soil nailing technology named as the PGSN (Pressurized Grouting Soil Nailing) system is respected to reduced displacements of nails and increase of global slope stability. And effects of various factors related to the design of the PGSN system, such as the length of the soil nail, injected pressure and W/C ratio of cement grout in the pressurized grouting soil nail are examined throughout a series of the displacement-controlled field pull-out tests. Displacement-controlled field pull-out tests are performed in the present study and the volume of grouting are also evaluated based on the measurements. In addition, both short-term and long-term characteristics of pull-out deformations of the newly proposed PGSN system are analyzed and compared with those of the general soil nailing system by carrying out the stress-controlled field pull-out tests. From the pull-out characteristics of pressurized grouting soil nails, it is found that the effect of the length of the soil nail, injected pressure and W/C ratio of cement grout are important parameters.

  • PDF