• Title/Summary/Keyword: Field Measuring System

Search Result 712, Processing Time 0.028 seconds

EIC integrated DCS with single console

  • Kawahara, Hiroshi;Hwa, Hong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.928-933
    • /
    • 1988
  • Control technology has been making remarkable progress in electrical control (E), instrumentation & control (I) and computer control (C) field respectively. In order to rationalize system engineering and simplify system configuration and operation work, so called, EIC are now to be integrated into one system. FUJI has developed it's own E, I&C integrated system, to meet above mentioned market requirements of variety. This paper describes basic concept of FUJI's Integrated Man-Machine Interface, hereinafter called SINGLE CONSOLE, from some view points of E, I, C integration technology.

  • PDF

A Study on Performance Test and Evaluation Technology of Tilting Vehicle (틸팅차량 성능시험 및 평가기술에 관한 연구)

  • Kim, Seog-Won;Han, Young-Jae;Kim, Young-Guk;Seo, Sung-Il;Lee, Su-Gil;Kim, Jong-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.272-274
    • /
    • 2004
  • Test evaluation field of railroad system that safety and reliability are important is to verify basic performances of unit products and system that were producted according to the specifications. Also, it is important works that verify finally in respect to commercialize verifying reliability and safety. As one part of system technology, this field is to construct database based on know-how of accumulated technology till now than high technical idea and, is to construct test evaluation system of railroad system that can utilize the constructed database. According to the necessity, our researchers investigated good measuring system of foreign country and performed research on performance test and evaluation technology of high-speed tilting vehicle that suits to domestic state.

  • PDF

Characteristics of HTS SQUID-based Susceptometer

  • Timofeev, V.P;Kim, C.G;Shnyrkov, V.I
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.82-85
    • /
    • 1998
  • A portable HTS RF SQUID-based system, weighing less than 20 kg has been built for susceptometry applications in weak magnetic fields, It includes a YBCO sensor for measuring the axial magnetic field component with a resolution of about $7{\times}10^{-13} T/Hz^{1/2}.$ This is determined by the intrinsic magnetic noise in the quasi-white noise region. There is a relaxation for a sudden increase in field due to magnetic flux creep in HTS. In this instance the time did not exceed 3~5 minutes.

  • PDF

Optimization of BIM based Space Plan by Expert System (전문가시스템을 활용한 BIM기반 건축공간 면적계획 최적화 방안)

  • Kwon, Ocheol;Cho, Joowon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.2
    • /
    • pp.99-110
    • /
    • 2016
  • The quality of building space program is a key to measure how the building performance satisfies its owner and users. However assuring its efficiency requires reliable criteria that reflect high level experience knowledge in the field. This study suggests a plan to gauge the level of building space performance using expert knowledge, which has not been utilized well enough but should play a critical role. In order to setup an expert system measuring level of the space program, we firstly optimized the space areas to the best case in a knowledgebase and use them as criteria to judge the quality of the spaces extracted from BIM model. We found the experimental results show us a promising way of measuring a relative quality of the space programs.

Two Plane Balancing Method based on the Equations of Motion of Rotor Dynamic System (회전체 동역학계의 운동방정식에 근거한 양면 밸런싱 기법)

  • Jeong, Dong-Hwa;Park, No-Gil
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.623-628
    • /
    • 2000
  • Since the influence coefficients method in balancing of rotors is developed with the basement of not the principle of rotor system dynamics, but the linear relationshop of between the measuring quantities and the unbalance quantities, field engineers can apply the method without additional understanding on the rotor dynamics. But the influence coefficients method is not robust to the measurement error. This paper proposes a new method for the two plane balancing of rigid rotor, based on the principle of rotor dynamics. And the kit for experiment is made by ourselves, and in order to measure in the same condition with it, we do a experiment three times. And then with the Response of gap sensor, the SNR(Signal and Noise) is compared and analyzed about measuring error between the influence coefficient method, and the new method, and it is proved that the new method is less robust than the influence coefficient method.

  • PDF

Development of Coercivity Measuring System for Ferromagnetic Materials in Open Magnetic Circuit (개방자기회로에서 강자성재료의 보자력 측정장치 개발)

  • 유권상;박진습
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.6
    • /
    • pp.297-301
    • /
    • 2000
  • Coercivity is defined as the magnetic field strength required to reduce the magnetic polarization to zero of magnetic specimen which has been previously magnetized to saturation. This quantity is a reference for classifying soft and hard magnetic materials. We have constructed the measuring system for measurement of coercivity of ferromagnetic materials in open magnetic circuit. The measurement range of the constructed system is from tens A/m to tens kA/m, the combined uncertainty is ${\pm}$0.22 kA/m as coercivity is 14.63 kA/m.

  • PDF

Auto-measurement of object by using image processor (영상처리기를 이용한 대상물체의 자동계측)

  • 백남칠;김영일;정영기;최호현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.484-487
    • /
    • 1987
  • In order to measure object larger than the optical field-of-view most video measurement systems utilize some sort of precision staging mechanism, and to utilize such a staging systems, Auto-Measurement System implemented in this paper has a precision of its own which affect the overall repeatability of the measuring instrument.

  • PDF

Implementation & Application of Instrumentation System on Performance Evaluation for Korea-Radio Train Control System (통신기반 열차제어시스템 성능평가용 계측시스템 구현 및 적용)

  • Lee, Jae-Ho;Lee, Kang-Mi;Park, Pyoung-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1777-1783
    • /
    • 2013
  • This study aims to implement an instrumentation system measuring and analysing real-time data of information flow between respective subunits composing train control system as the performance evaluation method for wireless communication based urban railway train control system under development for a Korean model. It analyses system functional requirements regarding subsystems composing wireless communication based train control system and test items for functions presented in each specification and examines data and measurement point for measuring according to test items in order to implement an instrumentation system. And, it clearly defines requirements of an instrumentation system to avoid malfunction or error in operation of train control system. It reviews data processing method and display method for effective analysis of data flow between respective subunits with measured data, designs and makes an instrumentation system. Ultimately, it applies to a performance test of train control system and makes sure an instrumentation system in normal working order.

Measurement Equipment Development of Stability Evaluation for Joint Slope using Unmaned Aerial Vehicle (무인항공기를 이용한 절리사면의 안정성평가 계측장비 개발)

  • Lee, Hyun Chol;Kwon, Ki Mun;Moon, Chang Eun;Jo, Yeong Hun
    • Tunnel and Underground Space
    • /
    • v.28 no.3
    • /
    • pp.193-208
    • /
    • 2018
  • In order to interpret rock slope safely and effectively, the mechanical properties of the rock must be carefully investigated. However, due to the limitations of clinometer usage, a new measure of measurement is required to complement these limitations. In this study, a measuring device was developed to analyze the characteristics of joint orientation, and to apply the orientation of joint to the field. The developed measuring equipment is divided into analysis software and hardware. The hardware was composed of a measuring module that measures the joint orientation of rock and a transport module that transmits the measurement data. The software was developed to analyze the orientation of the joint from the data obtained from the measuring module and is named Drone Joint Orientation Survey Measurement. The developed measuring equipment was well field capable if it could not be measured by the inspector, such as in areas where access was difficult, and was capable of effectively analyzing the lab test results for the orientation of the joint.

Design and Verification of Far-field measurement system for W-band Millimeter-wave Antenna (밀리미터파(W대역) 안테나 측정을 위한 원-전계 측정 시스템 설계 및 검증)

  • Baek, Jong-Gyun;Hwang, In-June;Cho, Chi-Hyun;Joo, Joung-Myoung;Joo, Ji-Han;Park, Jong-Kuk;Kim, Jaesik;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.43-50
    • /
    • 2022
  • In this paper, we designed and verified a Far-field measurement system for measuring the performance of an antenna operating in millimeter wave(W-band). For the antenna test, a measurement system should be selected according to the type of antenna, measurement items, measurement environment and period, etc. In the case of near-field measurement, it takes a lot of time because the number of measurement items increases when the antenna has multiple channels or various beams. Such an antenna can reduce the measurement time through Far-field measurement, and only necessary measurement items can be measured. Therefore, this study secured precise alignment of the far-field measurement system using a high-power laser and improved the measurement accuracy by applying a double amplifier system. The designed system was built in the anechoic chamber and verified by comparison with the verified Near-field measurement system.