• 제목/요약/키워드: Field Installation

검색결과 1,205건 처리시간 0.026초

수동루프 설치에 의한 송전선로 자계 저감 (Mitigation of Transmission Line Magnetic Field by Installation of Passive Shield-Loop.)

  • 김정부;신구용;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권2호
    • /
    • pp.59-61
    • /
    • 2006
  • In our country most of transmission lines are double-circuit lines. In these lines, the combining method of increasing conductor height and installation of passive shield-loop to mitigate magnetic field near a transmission line, is a good and feasible method. The basic principle of passive shield loop is that the field from the current induced in the shield loop conductors counteracts the field from the phase conductors. This method applied to domestic transmission lines to meet the magnetic field level, 100, 30, 10 and 4 mG, respectively. In each magnetic field level, the minimum conductor height and passive loop height are presented for the implementation of the practical design.

뇌방전에 의한 유도전압의 측정에 대한 기초적 연구 (A Basic Study on the Measurement Induced Voltages due to Lightning Discharges)

  • 이복희;조성철;엄주홍;이우철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.559-564
    • /
    • 2004
  • This paper deals with the device for measuring the time-varying magnetic fields and induced voltages caused by lightning discharges. The two magnetic field measuring systems were designed and made. One consists of the loop-type magnetic field sensor with the active integrator operated by a differential amplifier. The other consists of the loop-type magnetic field sensor and Labview software. The loop-type magnetic field sensor detects the time derivative of the magnetic field being measured, and the signal detected is integrated by the Labview software. As a consequence, from the calibration experiments, the frequency bandwidth of the full measuring system ranges from 400 [Hz] to 1 (MHz) and the response sensitivity are 0.98 (mV/nT) and 22 (mV/nT) for the magnetic field sensor of 2 turns and 6 turns, respectively. Also, the results obtained by the two measuring devices well agreed with each other.

  • PDF

비양기구로 운반되는 전계센서를 이용한 대기전계의 측정과 분석 (Measurement and Analysis of the Atmospheric Electric Field using Balloon-Carried E-Field Sensor)

  • 김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.78-84
    • /
    • 2016
  • This paper is focused on the measurement and analysis of an atmospheric electric field which is caused by thunderclouds. The electric field due to thunderclouds changes very slowly. For this reason, the extremely low frequency E-field sensor needs to be used for measuring the atmospheric electric field strength. The balloon-carried E-field sensor system with the time constant of 1sec was designed and fabricated. The electric field sensor consists of $100mm{\times}100mm$ copper plate, active integrator, high pass and low pass filters and batteries. The measurements of atmospheric electric fields were made by the balloon-carried E-field sensor and radiosonde, which sends the data back to ground in real time. From the calibration experiments, the response sensitivity of the E-field sensor was 0.154mV/kV/m in the frequency range of less than 1kHz. As a result from the actual experiment of the atmospheric electric field, the electric field signals were observed from the altitude of about 2.5km. Also, as the altitude was increased, the detected electric field wave oscillated with the fluctuation of sensing plate. The proposed method seems suitable for measurements of atmospheric electric fields, because it is inexpensive, simple to use and launch.

뒤채움 최대입도를 이용한 지오그리드 보강재의 시공손상계수 산정 방법 (Evaluation of Installation Damage Factor for Geogrid using Maximum Particle Size of Backfill Material)

  • 김경석;최영철;김태수;임성윤
    • 한국지반신소재학회논문집
    • /
    • 제6권4호
    • /
    • pp.29-37
    • /
    • 2007
  • 시공손상계수는 보강토 옹벽에 사용하는 지오그리드 보강재의 설계 강도 산정에 필요한 중요한 계수로서 실제 조건을 모사한 현장시험을 통해 구하고 있다. 하지만 지오그리드의 시공 중 발생하는 손상은 지오그리드의 재질, 단위면적당 중량, 뒤채움의 시공방법, 뒤채움의 입도에 따라 달라지며 현장시험을 통해 다양한 영향인자를 고려한 시공손상계수값을 도출하는데는 많은 시간과 비용이 소요된다. 본 연구에서는 시공손상에 영향을 미치는 인자들을 분석하고 뒤채움에 포함된 최대입경만을 이용하여 지오그리드 보강재의 시공손상계수를 산정하는 경험적 방법을 제시하였다.

  • PDF

유전 알고리듬을 이용한 송전선로 자계 저감용 도체루프의 최적 위치 선정 (Optimum Locations of Passe Conductor Loops for Magnetic Field Mitigation of Transmission Line using GA)

  • 신명철;김종형
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권5호
    • /
    • pp.234-241
    • /
    • 2005
  • The performance of passive conductor loop (hereinafter 'loop') method which is used to mitigate the magnetic field around overhead power transmission line is dependent on its configuration and installed location, which are affected by installation conditions of the loops such as objective areas and levels of magnetic field mitigation. Thus, because the design problem of loops is difficult and cumbersome by variety of their configuration and complexity of magnetic coupling mechanism, it is need to be formulated as a computer-based optimum problem to determine the most effective and reasonable loop model satisfying the installation conditions. In this paper, the optimum locations of the multi-wired multiple loops including series reactance compensations are searched by using the genetic algorithm (GA) to mitigate effectively the magnetic fields of relatively near points or far points from transmission line at Am height, and the magnetic fields mitigation characteristics of each loop are analyzed in the view of magnitude, direction and phase of cancellation fields by polarized vector concept to identify their adequacy and rationality for the installation objectives.

초고압 XLPE 전력케이블에 대한 설치후 교류내전압시험 현장적용 (Field Application of AC High Voltage Test after Installation for EHV XLPE Power Cables)

  • 김영;권병일;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1768-1770
    • /
    • 2001
  • EHV power cables can take any damage during shipping, transportation, handling, storage and installation. As the damage influences a reliability of the power cable system in the short and long periods, field tests have been required, for installers, to confirm the reliability of an installed system and, for utilities, to make sure the compatibility of an installed system. Of field tests, a HV withstand test for the cable insulation has been performed to check the soundness of the insulation. For EHV XLPE power cables, the test has been done by applying a specified d.c voltage till lately. But as some problems with the d.c test is emphasized and the equipment for the a.c test is improved, the a.c test is considered positively as an after-installation test. This paper describes the recent trends of the a and its recent application in the field.

  • PDF

자화인덕턴스 변화를 고려한 약계자 영역에서의 유도전동기 벡터제어 (Vector Control of an Induction Motor for the Field Weakening Region Considering the Variation of Magnetizing Inductance)

  • 이택기
    • 조명전기설비학회논문지
    • /
    • 제13권2호
    • /
    • pp.39-45
    • /
    • 1999
  • 약계자 영역에서 토크는 자속에 직접적으로 영향을 받는다. 이 영역에서는 자속준위는 회전자 속도에 대하여 반비례로 감소시킨다. 자속이 감소함에 따라 자화인덕턴스는 증가하게 된다. 자회인덕턴스는 전류를 제어하기 위한 접압을 제한한다. 본 노문에서는 약계자 영역에서 q-축전압을 측정함으로써 자화인덕턴스의 변화를 계산하며, 이에 따라 기준 자화전류를 재조정한다. 컴퓨터 시뮬레이션 실험결과를 통하여 제안한 방법을 입증한다. 본 연구에서 제안한 알고리즘은 방적기계등의 적용분야의 가변속 구동시스템에 활용이 기대된다.

  • PDF

2[MVA] 배전용 몰드변압기의 과도전계해석에 관한 연구 (A Study on the Transient Analysis of 2[MVA] Mold Transformer for Electric Field)

  • 전문호;김창업
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.171-176
    • /
    • 2010
  • This paper presents the electric field for 22.9[kV]/380[V], 2[MVA] mold transformer are analysed using FEM(finite element method). The electric field was calculated for the voltage applied to the transformer. Then, it is analysed that the maximum electric field occurred between high voltage turns. Capacitance is calculated with energy method. Surge impulse test simulation is studied by modeling circuit with capacitance and inductance. This paper obtain the result that is about influence of electric field in distribution mold transformer adopted.

현장에 타설된 연직배수재의 통수능력 분석 (Analysis on the Discharge Capacity of Vertical Drains Installed in the Field)

  • 박영목;진규남;정하익;정길수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.512-519
    • /
    • 2000
  • The discharge capacity of vertical drains installed in the field is reduced with time elapsed after installation due to deformation of drains and clogging effect. Discharge capacity of two types of vertical drains was analysed about three years after installation in the subsoil. Discharge capacity of two types of vertical drains were measured by small, middle, and large scale test apparatus. The results indicate that the discharge capacity of vertical drains after three years operation dramatically decreased compare to the initial discharge capacity.

  • PDF

코로나 방전에 대한 자계의 영향 (The effect of magnet fields on the corona discharge)

  • 박재윤;정장근;김익균
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.51-56
    • /
    • 2001
  • 본 논문에서는 침대평판 전극구조를 구성하여 침전극에 직류 정 ·부 고전압을 인가한 경우 전계와 자계가 직각방향으로 형성되도록 하고 자계가 코로나 방전현상에 미치는 영향을 측정하고 분석하였다. 정의 고전압을 인가한 경우 자계인가에 의해 방전코로나 영역이 확장되고 이때 흐르는 코로나전류가 감소하였고, 절연파괴전압은 증가되었다. 그러나 부의 고전압을 인가한 경우는 방전코로나 영역이 오히려 축소되고 흐르는 전류가 증가되었으며 절연파괴전압은 감소되었다. 이는 전자계가 동시에 존재하는 영역에서 코로나방전에 의해 생성된 전하들의 로렌쯔력에 의한 싸이크로트론 운동 때문인 것으로 생각된다.

  • PDF