• Title/Summary/Keyword: Field Bus

Search Result 211, Processing Time 0.019 seconds

Field Implementation of Voltage Management System (VMS) into Jeju Power System in Korea

  • Shin, Jeonghoon;Nam, Suchul;Song, Jiyoung;Lee, Jaegul;Han, Sangwook;Ko, Baekkyung;An, Yongho;Kim, Taekyun;Lee, Byungjun;Baek, Seungmook
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.719-728
    • /
    • 2015
  • This paper presents the results of field tests on Voltage Management System (VMS) using hybrid voltage control, which utilizes coordinated controls of various reactive power resources such as generators, FACTS and switched shunt devices to regulate the pilot bus voltage in a voltage control area. It also includes the results of performance test on RTDS-based test bed in order to validate the VMS before installing it in Jeju power system. The main purpose of the system is adequately to regulate the reactive power reserve of key generators in a normal condition with coordination of discrete shunt devices such as condensers and reactors so that the reserves can avoid voltage collapse in emergency state in Jeju system. Field tests in the automatic mode of VMS operation are included in steady-states and transient states. Finally, by the successful operation of VMS in Jeju power system, the VMS is proved to effectively control system voltage profiles in steady-state condition, increase system MVAR reserves and improve system reliability for pre- and post-contingency.

Antenna Test Range for Telecommunication Satellite (통신위성용 안테나 테스트 레인지)

  • Lim, Seong-Bin;Kim, Tae-Youn;Choi, Seok-Won;Sim, Eun-Sup
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.52-59
    • /
    • 2007
  • Telecommunication satellite consists of a bus system and an RF payload system with high efficiency and high gain reflector antennas. Antenna measurement and also RF system performance (antenna under test, payload and satellite level) have to be evaluated enough before launching in the far-field range or equivalent test range. Basically far-field range is required in a range from two hundred meters to several kilo meters, and it is highly constrained to the externa1 environment, like the RF and the whether environment So the compact antenna test range is developed and used efficiently without external environments as in-door facility. This paper describes the configuration of the compact antenna test range, the range error, and the physical concept of the plane wave illumination Also, it provides a overall design of the anechoic chamber and range parameter values to accommodate the precision measurements in antenna test range.

  • PDF

Analysis of Geomagnetic Field measured from KOMPSAT-1 Three-Axis Magnetometer (다목적위성 삼축자력계로부터 관측된 지구자기장에 관한 연구)

  • 김정우;황종선;김성용;이선호;민경덕;김형래
    • Economic and Environmental Geology
    • /
    • v.37 no.4
    • /
    • pp.401-411
    • /
    • 2004
  • The Earth's total magnetic field was calculated from on board TAM(Three-Axis Magnetometer) observations of KOMPSAT-1 satellite between June 19th and 21st, 2000. The TAM's telemetry data were transformed from ECI(Earth-Centered Inertial Frame) to ECEF(Earth-Centered Earth-Fixed Frame) and then to spherical coordination. Self-induced field from the satellite bus were removed by the symmetric nature of the magnetic field. The 2-D wavenumber correlation filtering and quadrant-swapping method were applied to eliminate the dynamic components and track-line noise. To test the validity of the TAM's geomagnetic field, ${\phi}$rsted satellite's magnetic model and IGRF2000 model were used for statistical comparison. The correlation coefficients between KOMPSAT-1/${\phi}$rsted and KOMPSAT-1/IGRF2000 models are 0.97 and 0.96, respectively. The global spherical harmonic coeffi-cient was then calculated from the KOMPSAT-1 data degree and order of up to 19 and compared with those from IGRF2000, $\phi$rsted, and CHAMP models. The KOMPSAT-1 model was found to be stable to degree & order of up to 5 and it can give new information for the low frequency components of the global geomagtic field.

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electrolyzer Loads (전해조 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Seo, Beom-Gwan;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.12-20
    • /
    • 2006
  • Heavy chemical industries have nonlinear loads including electrolyzers. The electrolysis consists of AC-BC converters which generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides in depth an analysis on harmonics field measurement for the electrolyzer loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonic assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.

The Design and Implementation of the Motorized Valve Control System using CANopen Protocol (CANopen 프로토콜을 이용한 전동밸브 제어시스템 설계 및 구현)

  • Lee, Myung-Eui;Shin, Keun-Soo;Yang, Sung-Hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.321-327
    • /
    • 2010
  • This paper deals with the design and development of the motorized valve control system using CANopen protocol. The CAN network protocol is used in the physical layer(layer 1) and data link layer(layer 2), and other upper network layer above that layer 1 and 2 utilize the CANopen protocol in this paper. The motorized valve controller is implemented by a PIC microprocessor, and the server application software for the control system user is written in C# language. In particular the CANopen protocol is widely used int the area such as ship automation systems and marine transportation systems. The experimental result of the proposed control system implemented in this paper is evaluated via real-time experiments, which works well as designed.

Guidelines Development of Living and Social Environmental Aspects for the Planning of Back-to-Farm Community Village (귀촌형 공동체마을 조성을 위한 생활환경과 사회환경 측면의 가이드라인 개발)

  • Park, Kyoung-Ok;Lee, Sang-Un;Jung, Ji-In
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • In order to give back-to-farm residents the stable settlement environment in the rural area, the 'community village' is desirable as the village type and its village planning guideline should be supported as well. The purpose of this study was to develop a guideline for the planning of back-to-farm community village in the living and social environmental aspects, based on the comprehensive comparative analysis about items that field survey and literature suggested. The guideline for the living environment was developed for 6 items; village structure(adequate size, lot, outer space for household), village landscape(allocation, space composition), road system and transportation(parking lot in village, placement of bus stops, village trail, public transportation, road and pedestrian system), common living facilities and common space(number, size, location & placement, plan type, planning type of common facilities), transfer space, individual housing(type, size, planning type). The guideline for the social environment was developed for 3 items; village making and establishment(resident participation type, resident participation tool, residents' construction participation) and resident education in the course of planning, resident participation(gathering resident opinion, decision making, composition of construction committee, community newsletter).

Development and Installation of Voltage Management System for Voltage and Reactive Power Control of Wide Area System (광역계통 전압/무효전력 관리를 위한 전압관리시스템의 개발 및 현장설치)

  • Nam, Su-Chul;Shin, Jeong-Hoon;Baek, Seung-Mook;Lee, Jae-Gul;Moon, Seung-Pil;Kim, Tae-Kyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1540-1548
    • /
    • 2010
  • KEPCO proposes enhanced voltage management system that is a coordinate voltage control system between the hierarchical voltage control system and the slow voltage control system. It has been installing in Jeju island. VMS consists of a master controller, CVC (Continuous Voltage Controller) and DVC (Discrete Voltage Controller). CVC consists of main controller, FDMU (Field Data Measurement Unit) and several RPDs (Reactive Power Dispatcher). CVC has a control scheme with AVRs of generator to maintain the voltage of a pilot bus in a power system, DVC has a control scheme with static reactive power sources, like a shunt capacitor, a shunt reactor, ULTC and so on, to maintain the reactive power reserve of a power system and a master controller is executed to recover reactive power margin of a power system through coordinated control between CVC and DVC.

Cell Culture Microbioassay for the Water Pollution Monitoring (세포배양 생화학적 기법에 의한 수환경오염 평가)

  • 오승민;정규혁
    • Toxicological Research
    • /
    • v.16 no.4
    • /
    • pp.285-291
    • /
    • 2000
  • So far, investigation of environmental pollution has been achieved in field study. This remains the most exhaustive approach, current dimensions of environmental researches and their inherent complexity require that relatively inexpensive and simple laboratory procedures are developed to make possible the screening of large numbers of sites and samples. At this point. microbioassay has been high-lighted. The purpose of this study is to evaluate the water pollution using microbioassay. Two microbioassay methods were optimized and validated for the sensitive and quantitative determination of total toxic effects in the water. EROD(Ethoxyresorufin-O-deethylase) microbioassay was focused to detect PARs, PCBs and dioxinlike components in the water and E-screen assay to xenoestrogens. The EROD microbioassay was executed in rat hepatoma cell line, H4IIE and E-screen assay in MCF7-BUS cell line. Kumho river was selected for this study. 5ι of river water was extracted using combined solid-phase extraction in static adsorption mode with soxhlet extraction. Pollutants adsorbed to the XAD-4 resin were recovered by elution with ethyl acetate and methylene chloride (1 : 9). Toxic effects of extracts were determined by EROD-microbioassay and E-screen assay. EROD activities of water samples were 7.24-72.24 ng/ι MEQ. The estrogenic effect of various water samples is quantitatively evaluated by EEQ. The EEQ of samples range from 0.05 to 6.07 ng-EEQ/ι. These results suggested that Kumho river was highly polluted with organic toxic chemicals.

  • PDF

A Fully Synthesizable Bluetooth Baseband Module for a System-on-a-Chip

  • Chun, Ik-Jae;Kim, Bo-Gwan;Park, In-Cheol
    • ETRI Journal
    • /
    • v.25 no.5
    • /
    • pp.328-336
    • /
    • 2003
  • Bluetooth is a specification for short-range wireless communication using the 2.4 GHz ISM band. It emphasizes low complexity, low power, and low cost. This paper describes an area-efficient digital baseband module for wireless technology. For area-efficiency, we carefully consider hardware and software partitioning. We implement complex control tasks of the Bluetooth baseband layer protocols in software running on an embedded microcontroller. Hardware-efficient functions, such as low-level bitstream link control; host controller interfaces (HCIs), such as universal asynchronous receiver transmitter (UART) and universal serial bus (USB)interfaces; and audio Codec are performed by dedicated hardware blocks. Furthermore, we eliminate FIFOs for data buffering between hardware functional units. The design is done using fully synthesizable Verilog HDL to enhance the portability between process technologies so that our module can be easily integrated as an intellectual property core no system-on-a-chip (SoC) ASICs. A field programmable gate array (FPGA) prototype of this module was tested for functional verification and realtime operation of file and bitstream transfers between PCs. The module was fabricated in a $0.25-{\mu}m$ CMOS technology, the core size of which was only 2.79 $mm{\times}2.80mm$.

  • PDF

A Study on the Implementation of CAN in the Distributed System of Power Plant (발전설비 분산제어 시스템에서 CAN 구축기술 연구)

  • Kim, Uk-Heon;Hong, Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.760-772
    • /
    • 1999
  • The CAN is a serial communication protocol for distributed real-time control and automation systems. Data generated from field devices in the distributed control of power plant are classified into three categories: real-time event data, real-time control data, non-real-time data. These data share a CAN medium. If the traffic of the CAN protocol is not efficiently controlled, performance requirements of the power plant system could not be satisfied. This paper proposes a bandwidth allocation algorithm that can be applicable to the CAN protocol. The bandwidth allocation algorithm not only satisfies the performance requirements of the real-time systems in the power plant but also fully utilizes the bandwidth of CAN. The bandwidth allocation algorithm introduced in this paper is validated using the integrated discrete-event/continuous-time simulation model which comprises the CAN network and distributed control system of power plant.

  • PDF