• Title/Summary/Keyword: Fibrous materials

Search Result 318, Processing Time 0.038 seconds

Arthroscopic Treatment of Osteochondritis Dissecans of the Talus (거골 박리성 골 연골염의 관절경적 치료)

  • Choi, Chong-Hyuk;Cheon, Yong-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.161-170
    • /
    • 2002
  • Purpose : To investigate arthroscopic simple excision for the treatment of osteochondritis dissecans of the talus and to examine gross change and histological evaluation of the defect through second look arthroscopy. Materials and Methods : This study included twenty-two patients who had osteochondritis dissecans of the talus that was treated with excision of arthroscopic loose body and necrotic bone tissue, leaving bleeding bed. In 7 cases, we performed second look arthroscopic examination for the evaluation of gross change of defects and histologic findings. Final results were evaluated with two clinical and functional protocols. Average follow up period was 42 months from 14 months to 8 years. Results : Ankle-hindfoot score (100 point) was improved significantly (p<0.003). Subjective and functional scores (100 points) averaged 82 points. The defect of lesion had a tendency of filling with fibrous tissue and fibrocartilage. Although the defect was filled with fibrocartilage, specific secondary lesion was not detected through second look arthroscopic examination. Conclusion : Arthroscopic debridement was an effective method for the treatment of osteochondritis dissecans of the talus without progression of secondary lesion even though the defect was filled with fibrocartilage.

  • PDF

Prediction of Lung Cancer Based on Serum Biomarkers by Gene Expression Programming Methods

  • Yu, Zhuang;Chen, Xiao-Zheng;Cui, Lian-Hua;Si, Hong-Zong;Lu, Hai-Jiao;Liu, Shi-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9367-9373
    • /
    • 2014
  • In diagnosis of lung cancer, rapid distinction between small cell lung cancer (SCLC) and non-small cell lung cancer (NSCLC) tumors is very important. Serum markers, including lactate dehydrogenase (LDH), C-reactive protein (CRP), carcino-embryonic antigen (CEA), neurone specific enolase (NSE) and Cyfra21-1, are reported to reflect lung cancer characteristics. In this study classification of lung tumors was made based on biomarkers (measured in 120 NSCLC and 60 SCLC patients) by setting up optimal biomarker joint models with a powerful computerized tool - gene expression programming (GEP). GEP is a learning algorithm that combines the advantages of genetic programming (GP) and genetic algorithms (GA). It specifically focuses on relationships between variables in sets of data and then builds models to explain these relationships, and has been successfully used in formula finding and function mining. As a basis for defining a GEP environment for SCLC and NSCLC prediction, three explicit predictive models were constructed. CEA and NSE are requentlyused lung cancer markers in clinical trials, CRP, LDH and Cyfra21-1 have significant meaning in lung cancer, basis on CEA and NSE we set up three GEP models-GEP 1(CEA, NSE, Cyfra21-1), GEP2 (CEA, NSE, LDH), GEP3 (CEA, NSE, CRP). The best classification result of GEP gained when CEA, NSE and Cyfra21-1 were combined: 128 of 135 subjects in the training set and 40 of 45 subjects in the test set were classified correctly, the accuracy rate is 94.8% in training set; on collection of samples for testing, the accuracy rate is 88.9%. With GEP2, the accuracy was significantly decreased by 1.5% and 6.6% in training set and test set, in GEP3 was 0.82% and 4.45% respectively. Serum Cyfra21-1 is a useful and sensitive serum biomarker in discriminating between NSCLC and SCLC. GEP modeling is a promising and excellent tool in diagnosis of lung cancer.

Microstructure and Magnetic Properties of Zn1-xCoxO Film Prepared by Pulsed DC Magnetron Sputtering (펄스 DC 마그네트론 스퍼터링법에 의한 Zn1-xCoxO 박막의 미세조직 및 자기적 특성)

  • Ko, Yoon-Duk;Ko, Seok-Bae;Choi, Moon-Soon;Tai, Weon-Pil;Kim, Ki-Chul;Kim, Jong-Min;Soh, Su-Jeung;Kim, Young-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.3 s.274
    • /
    • pp.211-217
    • /
    • 2005
  • [ $Zn_{1-x}Co_{x}O$ (x=0-0.3) films were grown on Corning 7059 glasses by asymmetrical bipolar pulsed dc magnetron sputtering. The c-axis orientation along (002) plane was enhanced with increasing Co concentration. The $Zn_{1-x}Co_{x}O$ films are grown with fibrous grains of tight dome shape. The transmittance spectra measured from UV-visible showed that sp-d exchange interactions and typical d-d transitions become activated with increasing Co concentration. The electrical resistivity of $Zn_{1-x}Co_{x}O$ films increased with increasing Co concentration, especially it increased greatly at $30at\% Co. X-ray photoelectron spectroscopy and alternating gradient magnetometer analyses indicated that no Co metal cluster is formed and the ferromagnetic properties are exhibited. The low electrical resistivity and room temperature ferromagnetism of $Zn_{1-x}Co_{x}O$ thin films suggested the possibility of the application to Diluted Magnetic Semiconductors (DMSs).

THE LONG-TERM CONSERVATIVE DRAINAGE CARE OF EXTENSIVE OSTEOMYELITIS ASSOCIATED WITH MANDIBULAR COMPOUND FRACTURE : REPORT OF A CASE (장기간의 보존적 배농술로 치료된 하악 복합골절 관련 광범위 골수염 치험 : 증례보고)

  • Kim, Ha-Rang;Yoo, Jae-Ha;Choi, Byung-Ho;Sul, Sung-Han;Mo, Dong-Yub;Lee, Chun-Ui
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.544-549
    • /
    • 2009
  • Failure to use effective methods of reduction, fixation and immobilization may lead to osteomyelitis with the exposed necrotic bone, as the overzealous use of transosseous wires & plates that devascularizes bone segments in the compound comminuted fractures of mandible. Once osteomyelitis secondary to fractures has become established, intermaxillary fixation should be instituted as early as possible. Fixation enhances patient comfort and hinders ingress of microorganisms and debris by movement of bone fragments. Teeth and foreign materials that are in the line of fracture should be removed and initial debridement performed at the earliest possible time. Grossly necrotic bone should be excised as early as possible ; no attempt should be made to create soft tissue flaps to achieve closure over exposed bone. The key to treatment of chronic osteomyelitis of the mandible is adequate and prolonged soft tissue drainage. If good soft tissue drainage is provided over a long period, sequestration of infected bone followed by regeneration or fibrous tissue replacement will occur so that appearance and function are not seriously altered. Localization and sequestration of infected mandible are far better performed by natural mechanism of homeostasis than by cutting across involved bone with a cosmetic or functional defect. As natural host defenses and conservative therapy begin to be effective, the process may become chronic, inflammation regresses, granulation tissue is formed, and new blood vessels cause lysis of bone, thus separating fragments of necrotic bone(sequestra) from viable bone. The sequestra may be isolated by a bed of granulation tissue, encased in a sheath of new bone(involucrum), and removed easily with pincettes. This is a case report of the long-term conservative drainage care in osteomyelitis associated with mandibular fractures.

MR Imaging of Intracranial Pediatric Meningiomas: Manifestations in 16 Patients (두개강내 소아 수막종 16예의 자기공명영상 소견)

  • Eo, Hong;Kim, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.188-196
    • /
    • 2008
  • Purpose : To describe the clinical, MR imaging, and pathologic findings of pediatric meningiomas. Materials and Methods : The authors retrospectively reviewed the medical records and MR images of 16 pediatric patients with pathologically proven meningioma. Mean patient age at diagnosis was 14 years (range, 3-18). MR images were reviewed for details of lesion sizes, locations, signal intensity (SI), marginal characteristics, internal architectures, enhancements, and dural and parenchymal changes. The findings of other imaging modalities and of pathological examinations were also analyzed. Results : Mean tumor size was 5.24 cm (range, 1.3-18.1 cm) and locations were supratentorial in 12 and infratentorial in 4. SI of masses were variable, that is, high in 9, iso in 4, and low in 3 on T2 weighted images (T2WI), and low (n=11), iso (n=4), or high (n=1) on T1WI images. All lesions were visualized as well-demarcated enhancing masses. Five of the tumors were heterogeneous with cystic or necrotic components. Dural attachment was observed in 11 patients and adjacent brain edema in 10. Tumors exhibited hyperdense (n=6) or isodense (n=4) on non-enhanced CT scans, and 3 of the 7 angiograms demonstrated blood supply from the internal carotid artery. Pathologic examinations revealed the following subtypes; transitional cell (n=4), meningotheliomatous (n=4), chordoid (n=2), fibrous (n=2), clear cell (n=1), hyalinized (n=1), rhabdoid papillary (n=1), and atypical (n=1). Conclusion : Pediatric meningiomas occur usually in teenagers, have diverse pathological types, and may produce atypical imaging findings, such as, a heterogeneous internal content or findings suggestive of intraaxial tumors.

  • PDF

BONE RESPONSE OF TWO DIFFERENT SURFACE TITANIUM SUBPERIOSTEAL IMPLANTS - ANODIZED SURFACE, IBAD HA COATING SURFACE (티타늄 임플랜트의 두 가지 표면처리방식에 대한 골반응 - 양극 산화표면, IBAD HA 코팅 표면)

  • Lee, In-Ku;Suh, Kyu-Won;Choi, Joon-Eon;Jung, Sung-Min;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.131-143
    • /
    • 2007
  • Statement of the problem: In case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve direct implant fixation to the bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implant. Purpose of study: This study was undertaken to evaluate bone response of ion beam-assisted deposition(IBAD) of hydroxyapatite(HA) on the anodized surface of subperiosteal titanium implants. Material and methods: Two half doughnut shape subperiosteal titanium implants were made. The control group was treated with Anodized surface treatment and the test group was treated with IBAD of HA on control surface. Then two implants inserted together into the subperiosteum of the skull of 30 rats and histological response around implant was observed under LM(light microscope) and TEM(transmission electron microscope) on 4th, 6th and 8th week. Results: Many subperiosteal implants were fixed with fibrous connective tissue not with bony tissue because of weak primary stability. The control group observed poor bone response and there was no significant change at any observation time. However the test group showed advanced bone formation and showed direct bone to implant contact under LM on 8th week. The test group observed much rER in the cell of osteoblast but the control group showed little rER under TEM. Conclusions: The test group showed better bone formation than the control group at the condition of weak primary stability. With these results IBAD surface treatment method on Anodized surface, may be good effect at the condition of weak primary stability.

Pathophysiology of Stiff Elbow (주관절 강직의 병태 생리)

  • Song, Hyun-Seok;Yoon, Hyung-Moon
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.286-292
    • /
    • 2010
  • Purpose: Stability of joints and maintenance of range of motion are needed for optimum function. The most common complaint about the elbow joint is joint stiffness. Recent articles have reported good outcomes in the treatment of stiff elbow joints. However, deciding which procedure to use is always difficult. Materials and Methods: Morrey et al. reported that the functional range of motion of the elbow joint is $30-130^{\circ}$ of flexion-extension and $50^{\circ}C$ of supination and pronation. About 90% of daily activities are done using this range of motion. Stiff elbow joints can be classified according to the traumatic events that caused the problem or the location of the main pathology. Intraarticular pathology includes severe articular mismatch, intraarticular adhesions, loss of articular cartilage, mechanical blockade by osteophytes, loose bodies, and hypertrophied synovium. Extraarticular pathology includes severe capsular adhesion due to the trauma or to dislocation, contracture of the collateral ligaments or muscles, bony bridge. Results and Conclusions: The main pathology underlying the loss of extension is the fibrous contracture of the anterior capsule. In this pathology, an anterior capsulectomy would be helpful. The main pathology underlying the loss of flexion is the contracture of the posterior band of medial collateral ligament.

Comparison of Airborne Asbestos Concentrations from Soils in Naturally Occurring Asbestos(NOA) Areas - Activity Based Sampling(ABS) vs. Real-time Asbestos Fiber Monitor(F-1 fiber monitor) - (자연발생석면지역의 토양 내 석면함유율에 따른 비산석면 농도평가 - 활동근거시료채취방법(ABS)과 실시간 섬유 측정 장치(F-1 fiber monitor) 결과 비교 -)

  • Jang, Kwangmyung;Park, Kyunghoon;Choi, Sungwon;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.245-256
    • /
    • 2017
  • Objectives: The present study is aimed at performing real-time measurement of fibrous materials using an F-1 fiber monitor, investigating the correlations between the measurements and environmental conditions, and assessing the feasibility of the use of the monitor in actual exposure assessments based on the accuracy and reliability of the device. Methods: Asbestos specimens with a fixed asbestos content were dispersed in a chamber and collected with a particle measuring test device. Measurements obtained by the existing PCM method, and with the F-1 fiber monitor were compared. In addition, concentrations of asbestos fibers obtained by the PCM method, the TEM method, and the F-1 fiber monitor were compared with that of specific ABS scenarios in NOA regions. Correlations of asbestos contents in soil and weather conditions with each method of measurement were analyzed. Results: Laboratory results showed that levels of asbestos fibers measured with each method increased as fiber contents in soil increased. In the accuracy and reproducibility assessment, no significant differences were found between the different methods of measurement. On-site assessment results showed positive correlations among the methods, and these correlations were less significant compared with what was shown by the laboratory results. Levels of asbestos fibers increased as asbestos contents in soil increased, and as temperature increased. Levels of asbestos fibers decreased as humidity increased, and wind speed did not significantly affect the extent to which asbestos fibers were scattered. Conclusions: While it would be premature to replace existing methods with the use of F-1 fiber monitors in real sites based on the results of this study, the monitor may be useful in the screening of the sites, which assesses hazard levels in different regions. Replacement of existing methods with the use of F-1 fiber monitors may be possible after the limitations identified in this study are overcome, and additional assessment data are obtained and reviewed under different conditions to confirm the reliability of the monitor in future research. Obtained assessment results may be used as basic data for the assessment of asbestos hazard in NOA regions.

The Strengthening Effects of Concrete Columns Confined with Carbon Fiber Sheets along the Fiber Direction (탄소섬유쉬트 올방향에 따른 콘크리트 기둥 보강성능)

  • Kim, Yang-Jung;Hong, Gap-Pyo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.326-332
    • /
    • 2011
  • Carbon, Aramid, Boron and Glass fibers are used as fibrous materials to promote structural bearing strength. Of these fiber types, carbon fiber is the most commonly used material, and is characterized by having a one-way direction, which is strengthened by tensile strength due to the attached direction only, while other types of fibers are two-way. Therefore, when applied in the field, the attachment direction of fiber is a very important factor. However, when fiber direction is not mentioned in the design drawing, there sometimes is no improvement in structural strength, as the fiber is being installed by a site engineer or workers who lack structural knowledge. The purpose of this study was to propose an optimal direction of carbon fiber through a comparison & analysis of reinforcing efficiency with reinforced experimental columns that used carbon fibers in each of the inclined, horizontal and vertical directions. According to the results, horizontal direction in the reinforced column was improved by 153.43%, but vertical direction was 104.61% only, and it was understood this was due to increased tensile strength along the fiber direction. For this reason, it is necessary to include information regarding fiber direction in design and site management.

Evaluation of the feasibility of bony window repositioning without using a barrier membrane in sinus lateral approach (상악동측방접근법시 차폐막을 사용하지 않는 골창재위치술의 유용성 평가)

  • Jeon, Seung-Hwan;Cho, Yong-Seok;Lee, Byung-Ha;Im, Tae-Yun;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.122-126
    • /
    • 2011
  • Introduction: In the lateral window approach for a maxillary sinus bone graft, there has been considerable controversy regarding the placement of a barrier membrane over the osteotomy site. In particular, when there is no damage to the Schneiderian membrane, clinicians should decide whether to use a barrier membrane or not, considering the benefits and costs. This study presents the clinical cases to demonstrate that only repositioning the detached window can lead to satisfactory bony healing of the grafted material without using a barrier membrane in the lateral approach for a maxillary sinus bone graft. Materials and Methods: Five consecutive patients were treated with the same surgical procedures. After performing the antrostomy on the lateral maxillary wall using a round carbide bur and diamond bur, the bony window was detached by a gentle levering action. After confirming no perforation of the Schneiderian membrane, the grafting procedure was carried out the detached window of the lateral maxillary wall was repositioned over the grafted material without using a barrier membrane. A gross examination was carried out at the postoperative 6 month re-entry, and the the preoperative and postoperative dental computed tomography (CT) at re-entry were compared. Results: All the procedures in the 5 patients went on to uneventful healing with no complications associated with the bone graft. Satisfactory bone regeneration without the interference of fibrous tissue on the gap between the repositioned window and lateral wall of the maxillary sinus was observed in the postoperative 6 month re-entry. The CT findings at re-entry revealed the, reconstruction of the external cortical plate including repositioned bony window. In addition, the loss of the discontinuity of the lateral maxillary wall was confirmed. Conclusion: This preliminary report showed that the detached window, which was just repositioned on the grafted material, could function as a barrier membrane in the lateral approach for a maxillary sinus bone graft. Therefore additional morphometric and histologic studies will be needed.