• 제목/요약/키워드: Fibrous capsule thickness

검색결과 10건 처리시간 0.028초

조직학과 효소활성 방법을 이용한 순 타이타늄과 타이타늄 합금의 상대적인 생체적합성 평가 (Relative Evaluation for Biocompatibility of Pure Titanium and Titanium Alloys using Histological and Enzymatic Methods)

  • 염동성;김병일;이유미;이은정;이성태;성치남;서권일;조현욱
    • Toxicological Research
    • /
    • 제23권4호
    • /
    • pp.331-339
    • /
    • 2007
  • Titanium or titanium alloy is a widely used implant material according to its certified biocompatibility, sufficient strength and ready availability. The purpose of this study was to evaluate the relative biocompatibility of titanium and titanium alloy specimens (Ti-29Nb-13Ta, TiNb and Ti-6Al-4V, Ti64) using in vivo and in vitro methods. For in vivo experiment, the specimens were implanted in the abdominal subcutaneous region of female mice for 2 and 4 weeks. The reaction of connective tissue to specimens was evaluated histologically. The specimens were encapsulated by fibrous connective tissue consisting of fibroblast, fibrocyte and other cells including neutrophil, macrophage, giant multinucleated cell and unidentified cells. Some newly formed blood vessels were located in the fibrous capsule surrounding the implant. Cell types and the thickness of fibrous capsules were examined quantitatively. Most of cell types located in the fibrous capsule were fibroblasts and fibrocytes. The average thickness of fibrous capsules for the TiNb specimens was much thinner than that of the titanium alloy, Ti64. The thickness of the fibrous capsule around all titanium specimens decreased at 4 weeks compared to 2 weeks post-implantation. The biocompatibility of titanium and titanium alloy specimens were also investigated in in vitro method using alkaline phosphatase from MG-63 cells. Alkaline phosphatase activity of the TiNb specimen showed higher activity than the titanium alloy, Ti64. In conclusion, the TiNb alloy with thin capsule thickness in vivo and high alkaline phosphatase activity in vitro will be of considerable use in biomedical applications.

In vivo와 in vitro 에서 양극산화 처리한 타이타늄 시편의 상대적인 생체적합성 평가 (Relative Biocompatibility Evaluation of Anodized Titanium Specimens in vivo and in vitro)

  • 이유미;이은정;염동선;김도순;이성태;김병일;조현욱
    • 생명과학회지
    • /
    • 제16권2호
    • /
    • pp.302-309
    • /
    • 2006
  • 처리하지 않은 타이타늄과 양극 산화 처리한 타이타늄 시편의 생체적합성을 평가하기 위해, 시편을 마우스의 복부 피하 조직에 이식하고 2주 동안 생존시켰다. 그 시편에 대한 복부 피하 결합조직의 반응을 조직학적으로 조사하였다. 시편 주위를 둘러싸는 섬유성 결합조직 막이 관찰되었으며 이 막은 섬유모세포, 섬유세포 및 기타 세포로서 중성호성백혈구, 대식세포, 거대다핵세포 등으로 이루어져 있었다. 시편을 둘러싸는 이 막에 새로이 형성된 혈관이 존재하기도 하였다. 임플란트와 접하는 섬유성 막에 거대다핵세포가 관찰되었다. 섬유성 막에 있는 세포 종류와 막의 두께를 조사하였다. 막에 있는 대부분의 세포는 섬유모세포와 섬유세포이었다. 양극 산화 처리를 하지 않은 타이타늄 시편에 비해 산화 처리를 한 시편을 둘러싸는 섬유성 막의 평균 두께가 더 얇았다. 또한 타이타늄 시편의 생체적합성을 세포 배양법으로 조사하였다. 산화 처리를 한 시편 위에서 배양한 MG-63 세포의 수가 유의하게 증가되었다. 이런 결과들은 in vivo 와 in vitro 실험에서 산화 처리를 한 타이타늄 시편이 생체적합성을 증가시키는데 효과적이라는 것을 말해준다.

마우스의 복벽에서 결합조직에 대한 금속 이식체의 생체적합성 비교 (Comparative Biocompatibility of Metal Implants in Connective Tissue of Abdominal Wall of the Mouse)

  • 김국렬;이민호;김병일;민병운;김명훈;최은상;조현욱
    • Toxicological Research
    • /
    • 제20권1호
    • /
    • pp.13-20
    • /
    • 2004
  • The purpose of this study is to compare the biocompatibility of commercial purity Ti, Ti-6AI-4V and Ti-6AI-7Nb alloy specimens with and without surface treatment in mouse abdominal connective tissue in vivo. Each metal was implanted into specific abdominal subdermal tissue site of female mouse. After 4 weeks, the implants were removed and abdominal tissues were fixed, dehydrated and embedded in glycol methacrylate resin. And the tissues were histologically prepared for microscopical evaluation. It was characterized by the presence of connective tissue with fibrous capsule surrounding the implant. The fibrous tissue surrounding the implant was studied to determine the biocompatibility of implanted metals. The average thickness of the fibrous capsule formed around the implant was much thinner for the hydrogen peroxide added hydrochloric acid solution-treated specimen than for the others. The results of this evaluation indicate that modification of the surface properties of titanium and titanium alloy implants changes the biological properties in the abdominal connective tissue. In conclusion, these observations suggest that the proper surface treatment performed in the study is effective for the improvement of biocompatibility.

쥐에서 오적골 생체적합성 평가 (Evaluation of the Biocompatibility of Cuttlebone in Mouse)

  • 원상철;이주명;정종태;박현정;서종필
    • 한국임상수의학회지
    • /
    • 제32권5호
    • /
    • pp.417-421
    • /
    • 2015
  • 골대체재는 지연유합이나 유합부전 그리고 골절술과 관절고정술 시 골편의 연속성 확립이 필요한 경우 골절의 주요 결손부위를 채우는데 주로 활용되고 있다. 자가골을 대체할 수 있는 천연 골이식재의 대표적인 것이 calcium carbonate (CC)이며, 갑오징어의 오적골(Cuttlebone, CB) 또한 천연 CC로 이루어져 있다. 본 연구에서는 오적골의 다양한 전처리 후 직경 5 mm 두께 2 mm의 형태로 가공하여 생체적합성을 평가하고자 하였다. 조직검사에서 결합조직 두께는 2, 4주차 모두 CBHA군에서 가장 유의성 있게 얇았다 (p < 0.05). 이상의 결과들은 CBHA가 생체 내에 적용하는 골대체재로서 생체적합성이 매우 높은 것으로 나타났다. 따라서 CBHA는 편평골에 있어 생체적합성이 뛰어난 골대체재로 그 가치가 있는 것으로 생각되며, 수의 임상에 있어서 활용성이 매우 높을 것으로 사료된다.

Oral tissue response to soft tissue expanders prior to bone augmentation: in vitro analysis and histological study in dogs

  • Yoo, Jung Min;Amara, Heithem Ben;Kim, Min Kyoung;Song, Ju Dong;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제48권3호
    • /
    • pp.152-163
    • /
    • 2018
  • Purpose: To determine whether the swelling and mechanical properties of osmotic self-inflating expanders allow or not the induction of intraoral soft tissue expansion in dogs. Methods: Three different volumes (0.15, 0.25, and 0.42 mL; referred to respectively as the S, M, and L groups) of soft tissue expanders (STEs) consisting of a hydrogel core coated with a silicone-perforated membrane were investigated in vitro to assess their swelling behavior (volume swelling ratio) and mechanical properties (tensile strength, tensile strain). For in vivo investigations, the STEs were subperiosteally inserted for 4 weeks in dogs (n=5). Soft tissue expansion was clinically monitored. Histological analyses included the examination of alveolar bone underneath the expanders and thickness measurements of the surrounding fibrous capsule. Results: The volume swelling ratio of all STEs did not exceed 5.2. In tensile mode, the highest mean strain was registered for the L group ($98.03{\pm}0.3g/cm$), whereas the lowest mean value was obtained in the S group ($81.3{\pm}0.1g/cm$), which was a statistically significant difference (P<0.05). In addition, the S and L groups were significantly different in terms of tensile strength ($1.5{\pm}0.1g/cm$ for the S group and $2.2{\pm}0.1g/cm$ for the L group, P<0.05). Clinical monitoring showed successful dilatation of the soft tissues without signs of inflammation up to 28 days. The STEs remained volumetrically stable, with a mean diameter in vivo of 6.98 mm, close to the in vitro post-expansion findings (6.69 mm). Significant histological effects included highly vascularized collagen-rich fibrous encapsulation of the STEs, with a mean thickness of $0.67{\pm}0.12mm$. The bone reaction consisted of resorption underneath the STEs, while apposition was observed at their edges. Conclusions: The swelling and mechanical properties of the STEs enabled clinically successful soft tissue expansion. A tissue reaction consisting of fibrous capsule formation and bone loss were the main histological events.

화학적 처리가 티타늄의 생체활성도에 미치는 영향 (EFFECT OF CHEMICAL TREATMENT ON THE BIOACTIVITY OF TITANIUM)

  • 민관식;이민호;안승근;박찬운
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.562-572
    • /
    • 2005
  • Statement of problem : Titanium is widely used as an implant material lot artificial teeth. Also, studies on surface treatment to form a fine passive film on the surface of commercial titanium or its alloys and improving bioactivity with bone have been carried out. However, there is insufficient data about the biocompatibility of the implant materials in the body. Purpose: The purpose of this study was to examine whether the precipitation of apatite on titanium metal is affected by surface modification. Materials and methods: Specimens chemically washed for 2 minute in a 1:1:1.5 (in vol%) mixture of 48% HF 60% $HNO_3$ and distilled water. Specimens were then chemically treated with a solution containing 97% $H_2SO_4$ and 30% $H_2O_2$ at $40^{\circ}C$S for 1 hour, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface were examined with TF-XRD, SEM, EDX and XPS. Also, commercial purity Ti specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. Conventional aluminium and stainless steel 316L were also implanted for comparison. Results and conclusions : The results obtained were summarized as follows. 1. An amorphous titania gel layer was formed on the titanium surface after the titanium specimen was treated with a $H_2SO_4$ and $H_2O_2$ solution. The average roughness was $2.175{\mu}m$ after chemical surface treatment. 2. The amorphous titania was subsequently transformed into anatase by heat treatment at $400^{\circ}C$ for 1 hour. 3. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $46.98{\mu}m$ in chemically-treated Ti, and 52.20, 168.65 and $100.95{\mu}m$ respectively in commercial pure Ti, aluminum and stainless steel 316L without any treatment.

토끼에서 오적골 이식 후 골 결손부 재생 평가 (Evaluation of the Bone Defect Regeneration after Implantation with Cuttlebone in Rabbit)

  • 원상철;이주명;박현정;서종필;정종태
    • 한국임상수의학회지
    • /
    • 제32권5호
    • /
    • pp.410-416
    • /
    • 2015
  • 골대체제는 지연유합이나 유합부전 그리고 골절술과 관절고정술 시 골편의 연속성 확립이 필요한 경우 골절의 주요 결손부위를 채우는데 주로 활용되고 있다. 본 연구에서는 오적골의 다양한 전처리 후 직경 5 mm 두께 2 mm의 형태로 가공하여 rhBMP-2의 담체로써 골전도력과 골유도력을 평가하고자 하였다. 결합조직의 두께는 2, 4주차 모두 오적골유래 hydroxyapatite 적용군(CBHA)에서 가장 유의성 있게 얇았다(p < 0.05). Radiologic gray-level histogram의 측정에서는 4주차에서 CBHA군이 산호유래 hydroxyapatite 적용군(CHA)군보다 유의성 있게 높게 나타났으며(p < 0.05), 12주차에서는 CHA군의 변화율이 가장 적었다. 전체 12주 동안의 변화율에서는 CBHA가 가장 많은 변화를 보였다. 폐쇄율에 있어서는 4, 8, 12주차 모두 CHA군이 다른 군에 비해 유의성 있게 높게 나타났으며(p < 0.05), 8주차에서는 bmp를 적용한 오적골 적용군(CB1bmp)이 CBHA군보다 유의성 있게 높게 나타났다(p < 0.05). 이상의 결과들은 CBHA가 생체 내에 적용하는 골대체재로서 골유도능력이 우수한 것으로 나타났다. 따라서 CBHA는 편평골에 있어 생체적 합성이 뛰어난 골대체재로 그 가치가 있는 것으로 생각되며, 수의 임상에 있어서 활용성이 매우 높을 것으로 사료된다.

H2O2/HCl 처리한 Ti 임플란트의 생체활성 평가 (Evaluation of Bioactivity of Titanium Implant Treated with H2O2/HCl Solution)

  • 유재선;권오성;이오연;이민호;송기홍
    • 한국재료학회지
    • /
    • 제15권5호
    • /
    • pp.353-360
    • /
    • 2005
  • Surface treatment play an important role in nucleating calcium phosphate deposition on surgical Ti implant. Therefore, the purpose of this study is to examine whether the precipitation of apatite on cp-Ti and Ti alloys are affected by surface modification in HCl and $H_2O_2$ solution. Specimens were then chemically treated with a solution containing 0.1 M HCl and 8.8M $H_2O_2$ at $80^{\circ}C$ for 30 mins, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface was examined with XRD, SEM, EDX ana XPS. Also, pure Ti, Ti-6Al-4V and Ti-6Al-7Nb alloy specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. All specimens chemically treated with HCl and $H_2O_2$ solution have the ability to form a apatite layer in the HBSS which has inorganic ion composition similar to human blood plasma. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $38.57\;{\mu}m,\;62.27\;{\mu}m\;and\;45.64\;{\mu}m$ in the cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloy specimens with the chemical treatment respectively, and $52.20\;{\mu}m,\;75.62\;{\mu}m\;and\;66.56\;{\mu}m$ in the commercial specimens of cp-Ti, Ti-6Al-4V and Ti-6Al-7Nb without any treatment respectively. The results of this evaluation indicate that the chemically treated cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloys have better bioactivity and biocompatibility compared to the other metals tested.

근관충전재(根管充塡材)의 매식(埋植)이 골조직(骨組織)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY OF THE EFFECTS ON THE BONE TISSUE BY IMPLANT OF ROOT CANAL FILLING MATERIALS)

  • 정재규;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.25-35
    • /
    • 1983
  • The purpose of this study was the observe the toxic effects of root canal sealers in 108 white rats. Experimental animals were divided into control and experimental groups. Theree representative types of materials, such as AH26, Z.O.E. and F.R. were used in this study. Cavities were prepared on the left mandibular area of 108 white rats. Three different sealers were placed in as experiment and bone cavities were left without filling as control. The experimental animals were sacrificed by cervical dislocation at the intervals of 1, 3, 7, 14, 28 and 49 days after filling. Each specimen was fixed with 10% neutral formalin solution, decalcified with 5% nitric acid, embedded in paraffin and sectioned 5-7${\mu}$. in thickness. The paraffin sections stained with Hematoxylin - Eosin were observed through the ordinary light microscope. The results were as follows; 1. Slight toxic effect to surrounding tissue were found in every experimental specimen. 2. AH26 showed the highest inflammatory response, and F.R. showed the lowest inflammatory response which subsided and replaced by fibrosis at 4 weeks after filling. 3. The cavity filled materials, such as implanted root canal sealers, blood clots and necrotic tissue, showed a tendency to be absorbed gradually proportioned to the experimental periods. A small amount of cavity filled materials were observed in the bone cavities after 4 weeks. 4. Fibroblastic proliferation began to produce fibrous capsule around the bone cavity in 2 weeks after filling. Fibrosis was prominent at 4 weeks after filling. 5. Osteoblastic activity of surrounding bone was observed at first in 2 weeks after filling and prominent in 4 weeks after filling. Osteoblastic activity showed an increasing effect as the time prolonged. 6. Surrounding tissue of the bone cavities showed the features of tissue destruction and had very severe inflammatory response at an initial stage. Above-mentioned appeared to be recovered gradually proportioned to the experimental periods.

  • PDF

폐암 세포주를 사용한 신, 비장 및 간 피막하 분식법의 비교 (Human Lung Cancer Cell Xenografts Implanted under the Capsule of Kidney, Spleen and Liver)

  • 김수현;김종인;이해영;조봉균;박성달;김송명
    • Journal of Chest Surgery
    • /
    • 제36권10호
    • /
    • pp.711-720
    • /
    • 2003
  • 배경: 폐암은 근치적 절제술이 가장 좋은 치료법이나 수술 후에 재발한 경우나 수술 시기가 지난 경우에는 항암 화학요법의 중요성이 강조된다. 항암 치료 전에 감수성 있는 항암 화학 치료제가 선별되어진다면 치료 효과를 극대화할 수 있다. 신피막하 분석법은 흉, 복부 종양의 생체 내 검사법으로 중요성이 인정되고 있고 항암 감수성 검사로서도 짧은 기간 내에 판별이 가능한 이점이 있다. 신장은 각종 암세포의 이식 장소로 잘 알려져 있으나 비장이나 간에서의 이식 성적을 비교한 연구는 없는 실정이다. 인체 암세포 이식의 실험방법 중에 비장과 간장에 암 세포주를 이식하였을 경우와 신장에 시행되는 신피막하 분석법에 의한 성장의 차이점 유무를 평가하였다. 대상 및 방법: 인체 폐암 세포주(SW-900 G IV)를 RPMI 1640 (Leibovitz L-15 medium)배지에서 배양하여 fibrin clot으로 만들어 $10^{8}$ 개의 암세포가 포함되도록 한 후 3${\times}$${\times}$3mm의 크기로 Spague Dawely (S.D.) 암컷 쥐의 신, 비장 및 간 피막하에 이식하였다. 이식 후 1일부터 6일간 면역억제를 위하여 cyclosporin-A (80 mg/kg)를 피하투여하였다. 이식 전후 실험동물의 체중 변화, 종양의 성장 여부 및 종양의 크기를 계측하고 병리 조직 검사와 혈청 내 암 표지자 검사를 실시하여 비교하였다. 걸과: 실험 5.D. 쥐의 체중 변화는 대조군이나 실험 군 모두에서 체중 증가가 있었다. 혈청 내 암 표지자의 정량 검사 결과 Cyfra 21-1은 검출되지 않았고, CEA및 NSE는 의미 있는 변화가 없었으며, SCC-Ag이 실험 군에서 유의한 증가가 있었다. 비장에 이식한 폐암 세포주의 성장이 신장 및 간장에 비해 더 증가된 결과를 보였다. 표면적, 두께와 용적 모두가 비장에서 유의한 증가를 나타내었다. 이식 성공률은 신장이 80%, 비장이 76.7%, 간장이 43.3%이었다. 병리학적 검사 결과 신장에는 비교적 둥글게 성장하며 크기는 제일 작았으며 성장 방향이 일정한 모양을 보이는 특징이 있으며 비장은 성장이 잘되어 제일 큰 종양을 형성하나 불규칙한 성장과 위성 종양(satellite tumor)이 빈번히 발견되었으며 현미경적으로는 혈관 신생과 함께 종양 혈전이 발견되었다. 간장은 간 내부로 침투 성장하여 이식 성공률이 가장 저조하며 현미경적 소견은 응고성 괴사와 점액양 섬유성 병변을 가지는 특징을 보였다. 걸론: 이식 성공률은 신장과 비장이 높으나, 성장이 일정하고 계측이 용이한 것은 신장이었다. 혈청 암 표지자는 SCC-Ag이 가장 조기에 반응하였으며, Cyfra 21-1은 조기에 검출되지 않았다. 이상에서 감수성 검사를 위한 종양이식 실험에 이용하기에 가장 적합한 장기는 신장을 이용한 신피막하 이식법으로 생각되며, 조기에 유용한 암표지자 검사는 SCC-Ag 정량법이라고 판단된다.