• Title/Summary/Keyword: Fiber-Cocktail

Search Result 19, Processing Time 0.026 seconds

An Experimental Study about Fire Resistance effect on steel fiber of the 90MPa column with Fiber-Cocktail (Fiber-cocktail을 혼입한 90MPa 강도 기둥의 강섬유 영향인자에 관한 실험적 연구)

  • Cho, Kyung-Suk;Kim, Heung-Ryul;Kim, Hyung-Jun;Park, Kyung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.419-420
    • /
    • 2010
  • High strength concrete(HSC) is made with Fiber-cocktail to control the spalling of HSC. In this paper, the column is made with PP fiber of $1.5kg/m^3$ and steel fiber of 20, 30, $40kg/m^3$, and the test are observed the temperature of reinforced bars and concrete. The results that increasing of temperature is delay as increase of steel fiber's volume.

  • PDF

A Study on Fire Performance of HPC Column with Fiber Cocktail in KS Fire Curve under Loading Condition (표준화재 재하조건에서 Fiber Cocktail을 혼입한 고강도 콘크리트 기둥의 강도별 화재거동에 관한 연구)

  • Kim, Heung-Youl;Chae, Han-Sik;Kim, Hyung-Jun;Jeon, Hyun-Kyu;Youm, Kwang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.377-380
    • /
    • 2008
  • The material and mechanical properties in the high temperature area of 40 to 100 MPa high strength concrete structural member was identified based on mixing of fiber cocktail and the structural element fire behavior simulation through the finite element analysis method (ABAQUS) was interpreted. The results are as follows. First, it was interpreted that the test specimen with concrete fiber cocktail mixed was more controllable in the maximum shrinkage than the one with concrete fiber cocktail not mixed the controllable range was about 25% to 55%. This means that shrinkage is controllable through mixing of fiber cocktail for the high strength concrete columns. Second, this study didn't consider the explosive spalling by the pore pressure within high strength concrete. If the properties for the pore pressure within high strength concrete is considered and database by strength and by inner temperature of various high strength concrete and steel materials are established in the future, it is interpreted that the technical foundation will be laid for performance based design of fire resistant construction.

  • PDF

A study on the fire performance and heat transfer of the HPC column with fiber-cocktail in ISO fire under loading condition

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kwon, In Kyu;Kwon, Ki-Hyuk;Min, Byung-Yeol;Cho, Bum-Yean
    • Computers and Concrete
    • /
    • v.12 no.5
    • /
    • pp.717-737
    • /
    • 2013
  • In this study, experiment and numerical analysis were conducted to identify the heat transfer characteristics and behavior of high-strength concrete upon a fire. The numerical analysis was employed to forecast the characteristics and properties of the high-strength concrete upon a fire, which can not be accomplished through a fire test due to the specific conditions and restrictions associated with the test. The result of the numerical analysis was compared with that of the test to verify the reliability of the analysis. In the numerical analysis of the heat transfer characteristics and behavior of 80 and 100 MPa high-strength concrete upon a fire, the commercial software of ABAQUS(V.6.8) was used. It was observed from the experiment that the contraction of the concrete with fiber-cocktail was mitigated by 25~55 % compared with that without fiber-cocktail because the fiber controlled the heat transfer of the concrete and thus improved the fire-resistance performance of the column.

Muscle Fiber Typing in Bovine and Porcine Skeletal Muscles Using Immunofluorescence with Monoclonal Antibodies Specific to Myosin Heavy Chain Isoforms

  • Song, Sumin;Ahn, Chi-Hoon;Kim, Gap-Don
    • Food Science of Animal Resources
    • /
    • v.40 no.1
    • /
    • pp.132-144
    • /
    • 2020
  • The aim of this study was to optimize staining procedures for muscle fiber typing efficiently and rapidly in bovine and porcine skeletal muscles, such as longissimus thoracis, psoas major, semimembranosus, and semitendinosus muscles. The commercially available monoclonal anti-myosin heavy chain (MHC) antibodies and fluorescent dye-conjugated secondary antibodies were applied to immunofluorescence histology. Two different procedures, such as cocktail and serial staining, were adopted to immunofluorescence analysis. In bovine muscles, three pure types (I, IIA, and IIX) and one hybrid type, IIA+IIX, were identified by the cocktail procedure with a combination of BA-F8, SC-71, BF-35, and 6H1 anti-MHC antibodies. Porcine muscle fibers were typed into four pure types (I, IIA, IIX, and IIB) and two hybrid types (IIA+IIX and IIX+IIB) by a serial procedure with a combination of BA-F8, SC-71, BF-35, and BF-F3. Unlike for bovine muscle, the cocktail procedure was not recommended in porcine muscle fiber typing because of the abnormal reactivity of SC-71 antibody under cocktail procedure. Within the four antibodies, combinations of two or more anti-MHC antibodies allowed us to distinguish pure fiber types or all fiber types including hybrid types. Application of other secondary antibodies conjugated with different fluorescent dyes allowed us to get improved image resolution that clearly distinguished hybrid fibers. Muscle fiber characteristics differed depending on species and muscle types.

A Study on Fire Performance and Heat Transfer of HPC Column with Fiber-Cocktail in ISO Fire under Loading Condition (표준화재 재하조건 Fiber Cocktail을 혼입한 고강도 콘크리트 기둥의 전열 특성 및 화재 거동에 관한 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Jeon, Hyun-Kyu;Youm, Kwang-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.29-39
    • /
    • 2010
  • In this study, experimental test and numerical analysis were conducted to investigate the heat transfer characteristics and fiber performance of high strength concrete. The fire characteristics of the high strength concrete that couldn't be obtained through the test due to specific requirements and restrictions were forecast using numerical analysis approach. The outcome from the numerical analysis and the test were compared to verify and improve the reliability of the analysis. A numerical analysis of 80 and 100 MPa high strength concrete cases were carried out to identify the heat transfer characteristics and fire behavior using software, ABACUS (V6.8) From the results of verification experiment, a 25~55% level of beam shrinkage reduction was observed compared to the concrete without Fiber-Cocktail, indicating the improved fire resistance performance, which appeared to be attributable to the function of Fiber-Cocktail that was able to control the heat transfer characteristics and ultimately result in enhancing the fire resistance performance.

An Experimental Study on The Fire Resistance Performance and Spalling of 100 MPa HSC Column Mixed Fiber-Cocktail (Fiber-Cocktail 섬유를 혼입한 100 MPa 고강도 콘크리트의 단면크기에 따른 폭렬 및 내화성능에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Yonl;Park, Kyung-Hoon;Yeo, In-Hwan;Kwon, Ki-Hyuck
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.85-92
    • /
    • 2011
  • Along the fire resisting capacity of high strength concrete has been brought up as a social issue, and the Ministry of Land also had notified the control standard about it, the researches for improving the fire resisting capacity have been considerably activated these days. In this study, we performed a research for developing a high strength concrete, contains the fiber cocktail, which is a hybrid of polypropylene fiber as organic matter, and steel fiber. As we analyzed the temperature of the steel part during the fire test with 100 MPa high strength concrete, there was a tendency that the lower temperature comes out with the larger cross section, and the $600{\times}600mm$, $800{\times}800mm$ cross sectioned can secure the fire resistance capability, so the $600{\times}600mm$ is deducted as the optimal size if we consider the double economic feasibility. As well, among them the best qualified $600{\times}600mm$ shapes, the fiber cocktail hybrid of $1.5kg/m^3$ PP fiber and $40kg/m^3$ of steel, comes out the best ratio.

Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns without Loading (섬유혼입공법을 적용한 고강도콘크리트 기둥의 비재하 내화시험)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Kim, Heung-Youl
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.465-471
    • /
    • 2009
  • To prevent the explosive spalling of the high strength concrete and control the rise of temperature in the steel rebar during fire, a fiber cocktail method has been proposed simultaneously with the use of polypropylene and steel fiber. After applying the fiber cocktail (polypropylene and steel fibers) into the mixture of high strength concrete with a compressive strength of between 40 and 100 MPa and evaluating the thermal properties at elevated temperatures, the fire test was carried out on structural members in order to evaluate the fire resistance performance. Two column specimens were exposed to the fire without loading for 180 minutes based on the standard curve of ISO-834. No explosive spalling has been observed and the original color of specimen surface was changed to light pinkish grey. The inner temperature of concrete dropped rapidly starting from 60mm deep. After 60 minutes of exposure to the fire, the temperature gradient of fiber cocktail reinforced high strength concrete was measured as 2.2oC/mm, which is approximately 5 times less than that of normal concrete. The final temperatures of steel rebar after 180 minutes of fire test resulted in 488.0oC for corner rebar, 350.9oC for center rebar, and 419.5oC for total mean of steel rebar. The difference of mean temperature between corner and center rebar was 137.1oC The tendency of temperature rise in concrete and steel rebar changed between 100oC and 150oC The cause of decrease in temperature rise was due to the water vaporization in concrete, the lower temperature gradient of the concrete with steel and polypropylene fiber cocktails, the moisture movement toward steel rebars and the moisture clogging.

A Study on the Fire Resistance Performance Concerning Types of Fire Protection Method and Load Ratio of High Strength Concrete Column Using The Wire Rope (와이어로프를 적용한 고강도 철근콘크리트 기둥의 내화공법 및 하중비에 따른 내화성능에 관한 연구)

  • Cho, Bum-Yean;Yeo, In-Hwan;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.64-71
    • /
    • 2012
  • The fire resistance test has been conducted under the standard fire & loading conditions to evaluate fire resistance performance, according to applying to methods of the lateral confinement reinforcement by prestressed Wire Rope and fire resistance reinforcement by Fiber-Cocktail and load ratio for high strength concrete column. The test result, for 60 MPa high-strength concrete column, It was indicated that applying to the wire rope has improved axial ductility in the fire condition, and fire resistance performance has been enhanced by more than 23 %. In addition to this, in case of applying the wire rope to 60 MPa high-strength concrete column, load can be judged that about 70 % of designed load is appropriate. If the Wire Rope and Fiber-Cocktail is applied to 100 MPa high-strength concrete column, It was shown that the fire resistance performance was enhanced by 4 times as much as applying only hoops.

A Study on Thermal Analysis with Strength Characteristics of HPC Column with Fiber Cocktail in KS Fire Curve (표준화재조건에서 Fiber Cocktail을 혼입한 고강도 콘크리트 기둥의 강도별 전열특성에 관한 연구)

  • Kim, Heung-Youl;Chae, Han-Sik;Kim, Hyung-Jun;Jeon, Hyun-Kyu;Youm, Kwang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.397-400
    • /
    • 2008
  • To carry out this study efficiently, the material, physical and mechanical properties of the existing high temperature area was identified and the thermal transportation of structural elements was carried out through the finite element analysis method(ABAQUS) for 40 to 100 MPa high strength concrete based on Fiber Cocktail mixing. The results are as follows. First, it was analyzed that 40, 50 and 60 MPa high strength concretes have a thermal transportation properties similar to the analysis model of 30 MPa normal concrete. Second, it was analyzed that the analysis model of 80 and 100 MPa high strength concrete have slightly lower thermal transportation properties compared to normal model. Third, this study didn't consider the explosive spalling by the pore pressure within high strength concrete. If the properties for the pore pressure within high strength concrete is considered and database by strength and by inner temperature of various high strength concrete and steel materials are established in the future, it is interpreted that the technical foundation will be laid for performance-based design of fire-resistant construction.

  • PDF

Fire Resistance Performance of Fiber-Cocktail Reinforced 50 MPa High Strength Concrete (섬유혼입된 50 MPa 고강도 콘크리트의 내화성능)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Park, Jong-Heon
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.3
    • /
    • pp.55-60
    • /
    • 2009
  • After applying the fiber cocktail(polypropylene and steel fibers) into the mixture of high strength concrete with a compressive strength of 50 MP, the fire test was carried out on specimens in order to evaluate the fire resistance performance, such as possible explosive spalling, temperature distributions of concrete and rebar. According to an enforcement ordinance, four column specimens were exposed to the fire for 180 minutes based on the standard curve of ISO-834. No explosive spalling has been observed. The required minimum quantity of polypropylene to prevent explosive spalling is more than 0.57 kg per unit concrete volume. The comparing test results from temperature distributions of concrete and rebar has found that the difference of fiber quantity is insignificant.

  • PDF