• Title/Summary/Keyword: Fiber Selection

Search Result 185, Processing Time 0.022 seconds

Dynamic Analysis of Carbon-fiber-reinforced Plastic for Different Multi-layered Fabric Structure (적층 직물 구조에 따른 탄소강화플라스틱 소재 동적 특성 분석)

  • Kim, Chan-Jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.375-382
    • /
    • 2016
  • The mechanical property of a carbon-fiber-reinforced plastic (CFRP) is subjected to two elements, carbon fiber and polymer resin, in a first step and the selection of multi-layered structure is second one. Many combination of fabric layers, i.e. plainweave, twillweave, can be derived for candidates of test specimen used for a basic mechanical components so that a reliable identification of dynamic nature of possible multi-layered structures are essential during the development of CFRP based component system. In this paper, three kinds of multi-layered structure specimens were prepared and the dynamic characteristics of service specimens were conducted through classical modal test process with impact hammer. In addition, the design sensitivity analysis based on transmissibility function was applied for the measured response data so that the response sensitivity for each resonance frequency were compared for three CFRP test specimens. Finally, the evaluation of CFRP specimen over different multi-layered fabric structures are commented from the experimental consequences.

Buckling Strength Analysis of Stiffened Composite Plates for the Optimum Laminate Structure (최적 적층구조를 위한 보강된 복합적층판의 좌굴강도 해석)

  • H.R.,Kim;J.W.,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 1989
  • The optimun laminated composition of the stiffened composite plates is studied from the view point of buckling strength. The finite element method is applied to the buckling analysis of the composite plates taking into account the effect of shear deformation through the plate thickness. The stiffened plate model is discretized using plate thickness and symmetrically stacked. Parametric study is carried out for the selection of the optimum laminate structure; optimum fiber angle sequence through the thickness. Laminate structure of $[-45^{\circ}/45^{\circ}/90^{\circ}/0^{\circ}]$, is found to give the best buckling strength. For the case of that layer number is more than eight, best result is obtained when layers of the same fiber angle are put together, leaving the laminate has the same fiber angle sequence as a whole.

  • PDF

Development of high performance hybrid fiber reinforced concrete using different fine aggregates

  • Gupta, Hitesh;Bansal, Prem Pal;Sharma, Raju
    • Advances in concrete construction
    • /
    • v.11 no.1
    • /
    • pp.19-32
    • /
    • 2021
  • In the present experimental study, the high performance hybrid fiber reinforced concrete (HPHFRC) is prepared using the Modified Andreasen and Andersen (A&A) particle packing model. Total of 16 trial mixes of HPHFRC with Indian standard sand (SS) and natural river sand (NS) are prepared to achieve the selection criteria (flow percent>150 and compressive strength>80 MPa). Based on the flow percent and compressive strength criteria, the selected mixes evaluated to study the effect of usage of natural river sand (NS) and the expensive Indian standard sand (SS) on the mechanical, durability, and microstructure property of designed HPHFRC. It has been found that the Modified A&A model is reliable to design the mix for HPHFRC with excellent mechanical, durability, and microstructure properties. In addition to that, a moderate difference in the mechanical and durability properties of NS contained HPHFRC and SS contained HPHFRC is found. Based on the obtained results of NS contained HPHFRC, it can be concluded that the use of natural river sand (NS) can be successfully adopted for the production of HPHFRC, resulted in a reduction of the production cost without compromising the excellent performance of HPHFRC.

Numerical Study for Seismic Strengthening of RC columns Using Fiber Reinforced Plastic Composite (기둥의 내진성능 향상을 위한 섬유보강 복합체의 적용성에 대한 해석적 연구)

  • Chang, Chun Ho;Kwon, Min Ho;Kim, Jin Sup;Joo, Chi Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.117-127
    • /
    • 2012
  • As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. Fiber reinforced plastic composite material is one of strengthening material widely used to increase seismic performance of structures. It should have high stiffness as well as large ductility to provide best strengthening result. Thus selection of stiffener and fiber in composite is of important. In this study, the optimal combination of fiber and stiffener is selected with variety of tensile tests. In order to investigate performance of chosen composite material, several finite element analyses are performed with proposed FRP composite material for existing RC columns. It is discussed that the seismic performance of strengthened columns through the load-displacement relationship. It is shown that the proposed composite material can increase the strength as well as ductility of exiting RC columns.

Investigation of Adhesion property between Glass Fiber Reinforced Plastic and Polyurethane adhesives on Peel strength under Gyogenic tempernture (극저온에서 유리섬유강화플라스틱 표면의 유리섬유와 폴리우레탄 접착제간의 접착특성이 전체 박리강도에 미치는 영향에 대한 연구)

  • Shon, Min-Young;Lee, Jae-Kwang;Hong, Jeong-Lak
    • Composites Research
    • /
    • v.22 no.4
    • /
    • pp.13-19
    • /
    • 2009
  • Adhesive joints are widely used for structural joining applications in various fields and environmental conditions. Polyurethane adhesive is using for LNG carrier with cryogenic temperature condition. Even if similar polyurethane adhesive is used for different substrate, it shows different adhesion properties. Specially, variation of adhesion properties depending on the resin system or fiber is very important factor for selection of adhesive on industrial application. In present study, we got different peel strength according to the different test temperature when different polyurethane adhesive was used for same fiber reinforced composite. The main cause was investigated using by SEM and it was proven that the different adhesion property between glass fiber on composite surface and polyurethane adhesives at cryogenic temperature.

Competing Modes in Erbium Doped Fiber Ring Lasers

  • Abd-Rahman, M.Kamil;Selvakennedy, S.;Ahmad, Harith
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.5-8
    • /
    • 2002
  • The erbium doped fibre ring laser (EDFL) is modelled using the standard propagation and rate equations of a homogeneous, two-level gain medium. The EDFL numerical simulations provide comparable results with the experimental data. The process of lasing mode competition and mode selection is clearly depicted and explained.

  • PDF

The Analysis on the Upsteam band Signal in the HFC Access Network (HFC 가입자망 상향대역 신호분석에 관한 연구)

  • 장문종;김선익;이진기
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10c
    • /
    • pp.142-144
    • /
    • 2004
  • To provide more qualified data service on the HFC(Hybrid-Fiber Coaxial) access network, the channel characteristics of upstream transmission band should be carefully investigated and analysed. It will be easier to do network management if the monitoring system for noise measurement in the network is available, In this paper, noise analysis method and the frequency selection method in the upstream band for duplex transmission are suggested. And, Data aquisition device for the signal measurement Is implemented. With this network monitoring system, field test and the result from the collected data are described.

  • PDF

Effect of Braid Structure on Yarn Cross-Sectional Shape

  • Lyons, Jason;Pastore, Christopher M.
    • Fibers and Polymers
    • /
    • v.5 no.3
    • /
    • pp.182-186
    • /
    • 2004
  • The effect of braid construction parameters on yarn cross-sectional shape is presented in this paper. The location of the yam within the braid unit cell is quantified by a compaction factor. A range of braided fabrics were produced and optically measured for actual yarn cross-sectional shape. A comparison of the theoretical and experimental values shows good correlation. Design curves can be produced with the developed model to allow selection of appropriate braid process parameter to create yarns with desired cross-sectional geometries.

Stiffness Comparison with Design of GFRP Roof Panels Prepared by RTM Method (RTM 성형 GFRP 차체 설계에 따른 강성연구)

  • 유용문;윤의박;윤여성;이순홍
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.32-38
    • /
    • 1998
  • In order to investigate the relationship between the stiffness and structure of the automotive roof panels, two kinds of glass fiber reinforced plastic(GFRP) roof panels without and with insert material were fabricated by resin transfer molding(RTM) method. The stiffness test was performed at the same condition as it of actual driving. The structural design and material selection for improving the recyclability of GFRP roof panels were also covered.

  • PDF

Heuristics for Selecting Nodes on Cable TV Network (케이블 TV 망에서 노드 선택을 위한 휴리스틱 연구)

  • Chong, Kyun-Rak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.133-140
    • /
    • 2008
  • The cable TV network has delivered downward broadcasting signals from distribution centers to subscribers. Since the traditional coaxial cable has been upgraded by the Hybrid Fiber Coaxial(HFC) cable, the upward channels has expanded broadband services such as Internet. This upward channel is vulnerable to ingress noises. When the noises from the children nodes accumulated in an amplifier exceeds a certain level, that node has to be cut off to prevent the noise propagation. The node selection problem(NSP) is defined to select nodes so that the noise in each node does not exceed the given threshold value and the sum of Profits of selected nodes can be maximized. The NSP has shown to be NP-hard. In this paper, we have proposed heuristics to find the near-optimal solution for NSP. The experimental results show that interval partitioning is better than greedy approach. Our heuristics can be used by the HFC network management system to provide privileged services to the premium subscribers on HFC networks.

  • PDF