• Title/Summary/Keyword: Fiber Bragg Gratings

검색결과 111건 처리시간 0.035초

Impact of CO2 Laser Pretreatment on the Thermal Endurance of Bragg Gratings

  • Gunawardena, Dinusha Serandi;Lai, Man-Hong;Lim, Kok-Sing;Ahmad, Harith
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.575-578
    • /
    • 2016
  • The thermal endurance of fiber Bragg gratings (FBGs), written with the aid of 193-nm ArF excimer laser irradiation on H2-loaded Ge/B codoped silica fiber, and pretreated with a CO2 laser and a subsequent slow cooling process, is investigated. These treated gratings show relatively less degradation of grating strength during the thermal annealing procedure. The thermal decay characteristics of treated and untreated fiber, recorded over a time period of 9 hours, have been compared. The effect on the Bragg transmission depth (BTD) and the center-wavelength shift, as well as the growth of refractive-index change during the grating inscription process for both treated and untreated fiber, are analyzed.

FBG를 삽입한 사냑 루프 대역 통과 필터의 해석 (Analysis of Sagnac Loop Band-pass Filter in Incorporating Fiber Bragg Gratings)

  • 정은주;정명영;김창석
    • 한국광학회지
    • /
    • 제18권2호
    • /
    • pp.105-110
    • /
    • 2007
  • 사냑 고리 광섬유 간섭계의 특성을 이용하여 FBG의 반사특성을 투과특성으로 전환하는 고효율의 파장 선택 필터를 제안하고 수식적으로 분석 및 구현하였다. 제안된 대역 투과 필터는 사냑 고리 간섭계 구조에 FBG를 삽입하여 구현하였다. 고효율의 가변형 파장 선택 필터는 편광조절기에 의해 FBG 브래그 파장영역이외의 영역은 사냑 효과로 광의 세기를 가변적으로 투과하도록 조절하였고, 브래그 파장영역에서는 마이켈슨 간섭효과로 20 dB 이상의 소멸비를 갖는 광 투과를 얻었다.

Temperature-difference Flow Sensor Using Multiple Fiber Bragg Gratings

  • Kim, Kyunghwa;Eom, Jonghyun;Sohn, Kyungrak;Shim, Joonhwan
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.297-303
    • /
    • 2022
  • Multiple fiber Bragg gratings (FBGs) have been proposed and demonstrated for gas-flow measurements in a flow channel, using the temperature-difference method. This sensor consists of two FBG temperature sensors and two coil heaters. Coil heaters are used to heat the FBGs. The flow rate of the gas can be obtained by monitoring the difference in the Bragg-wavelength shifts of the two FBGs, which has features that exclude the effect of temperature fluctuations. In this study, experiments are conducted to measure the wavelength shift based on the flow rate, and to evaluate the gas-flow rate in a gas tube. Experimental results show that the sensor has a linear characteristic over a flow-rate range from 0 to 25 ℓ/min. The measured sensitivity of the sensor is 3.2 pm/(ℓ/min) at a coil current of 120 mA.

광섬유 격자소자를 이용한 협대역 투과 필터의 설계 (Design of narrow band-pass filter using two fiber bragg gratings)

  • 임종훈;이경식
    • 전자공학회논문지D
    • /
    • 제35D권8호
    • /
    • pp.82-88
    • /
    • 1998
  • We propose and design a new type of anrrow band-pass optical filter based on two fiber gratings with different reflection wavelength. The ripples occur in the spectra of the filter with two uniform fiber gratings. Our simulation results also show that the ripples disappear with the fiber gratings apodized to both gaussian and hyperbolic tangent function. The hyperbolic tangent function seems to be a better apodization function for improving the filter's performance in terms of narrow pass bandwidth and high transmission.

  • PDF

Uniform-fiber-Bragg-grating-based Fabry-Perot Cavity for Passive-optical-network Fault Monitoring

  • Xuan, Zhang;Ning, Ning;Tianfeng, Yang
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.47-53
    • /
    • 2023
  • We propose a centralized passive-optical-network monitoring scheme using the resonance-spectrum properties of a Fabry-Perot cavity based on fiber Bragg gratings. Each cavity consists of two identical uniform fiber Bragg gratings and a varying cavity length or grating length, which can produce a unique single-mode resonance spectrum for the drop-fiber link. The output spectral properties of each cavity can be easily adjusted by the cavity length or the grating length. The resonance spectrum for each cavity is calculated by the transfer-matrix method. To obtain the peak wavelength of the resonance spectrum more accurately, the effective cavity length is introduced. Each drop fiber with a specific resonance spectrum distinguishes between the peak wavelength or linewidth. We also investigate parameters such as reflectivity and bandwidth, which determine the basic performance of the fiber Bragg grating used, and thus the output-spectrum properties of the Fabry-Perot cavity. The feasibility of the proposed scheme is verified using the Optisystem software for a simplified 1 × 8 passive optical network. The proposed scheme provides a simple, effective solution for passive-optical-network monitoring, especially for a high-density network with small end-user distance difference.

반사 파장 선폭 확장을 위해 장력 조절기를 적용시킨 광섬유 브래그 격자(Fiber Bragg grating) 제작 기술 (Fabrication of Fiber Bragg gratings using a tension controller for broad wavelength linewidth)

  • 최보훈
    • 한국정보통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.350-356
    • /
    • 2012
  • 가우스 광분포를 가지는 KrF 엑시머 레이저 빔과 위상마스크를 이용하여 광섬유 브래그 격자를 제작하고 제작된 격자의 장력에 대한 특성 변화가 측정되었다. 3 nm 범위 내에서 브래그 파장은 1.24 nm/10kpsi 로 선형적으로 변화하였다. 외부 장력 인가 장치와 광섬유 제작 장치를 결합하여 하나의 위상 마스크로 4 개의 중심 파장이 다른 광섬유 격자를 제작한 뒤 이들을 이용하여 기존의 단일 광섬유 브래그 격자로 얻을 수 있는 파장 선폭보다 2배 증가된 1.5 nm 인 3 dB 대역폭을 갖는 광섬유 브래그 격자를 얻었다.

Hydrogen Sensor Based on Palladium-Attached Fiber Bragg Grating

  • Lee, Sang-Mae;Sirkis, Jim-S.
    • Journal of the Optical Society of Korea
    • /
    • 제3권2호
    • /
    • pp.69-73
    • /
    • 1999
  • This paper demonstrated the performance of a palladium wire hydrogen sensor based on a fiber Bragg grating as a means of developing a quasi-distributed hydrogen sensor network capable of operating at cryogenic temperatures. The new approach employing a fiber Bragg grating based palladium hydrogen sensor described in this study is advantageous over other traditional hydrogen sensors because of the multiplexing capability of fiber Bragg gratings. The sensitivity of the hydrogen sensor at room temperature is approximately 2.5 times that of the hydrogen sensor at cryogenic temperatures.

광섬유 브래그 격자(Fiber Bragg grating) 제작과 제작 조건에 따른 특성 향상 (Fabrication optimization of Fiber Bragg gratings)

  • 최보훈
    • 한국정보통신학회논문지
    • /
    • 제14권7호
    • /
    • pp.1680-1686
    • /
    • 2010
  • 가우스 광분포를 가지는 248nm 파장의 KrF 엑시머 레이저 빔과 1.072um 주기를 가지는 위상마스크를 이용하여 최저 투과율 파장이 1549.9nm 인 광섬유 브래그 격자(Fiber Bragg Grating)를 제작하였다. 레이저 빔과 마스크 그리고 광섬유의 최적 정렬 과정을 조사하기 위해 평행 정렬 오차와 각 정렬 오차가 조사되었고 또한 엑시머 레이저의 투과 에너지와 발진 주파수의 변화에 따른 영향도 조사되었다. 실험 결과 얻어진 최적 정렬 조건 하에서 제작된 광섬유 격자의 광 투과 스펙트럼 형성 과정을 측정하여 특성이 분석되었고 이 같이 사용된 제작 조건의 안정성을 확인하기 위해 재현성 실험이 수행되었다.

광섬유 브래그 격자의 고온 어닐링 조건에 따른 방사선 영향 (Radiation Effects of Fiber Bragg Gratings on the High Temperature Annealing Condition)

  • 김종열;이남호;정현규;임돈순
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.785-787
    • /
    • 2016
  • 본 논문에서는 광섬유 브래그 격자의 고온 어닐링 온도조건에 따른 감마방사선 영향을 분석하였다. 제작된 광섬유 브래그 격자는 $Co^{60}$ 감마선원을 이용하여 약 115 Gy/min의 선량률로 총선량 약 31 kGy 감마선을 조사하였다. 실험결과를 통하여, 각각 다른 온도로 안정화시킨 광섬유 브래그 격자들은 높은 온도에 노출될수록 방사선 민감도가 증가하는 것으로 나타났다.

  • PDF

회전기와 첩 광섬유 격자를 이용한 가변 분산 보상기 (Tunable dispersion compensator based on chirped fiber bragg gratings with a mechanical rotator)

  • 김준희;배준기;한영근;김상혁;이상배;정제명
    • 한국광학회지
    • /
    • 제15권2호
    • /
    • pp.100-103
    • /
    • 2004
  • 본 논문에서는 첩 광섬유 격자를 이용한 가변 분산 보상기를 소개한다. 개발된 가변 분산 보상기는 금속판의 벤딩에 의해 유도되는 인장력과 수축력에 대한 분석을 기반으로 첩광섬유 격자의 분산 값을 제어할 수 있도록 설계되었으며, 제작된 분산 보상기는 단순히 금속 원판의 회전만으로 광섬유 격자에 선형적인 인장력과 수축력을 유도하곤 중심파장의 이동이 없이 분산 값을 변화시킬 수 있었다. 분산 값은 회전각의 변화에 따라 228.04 ㎰/nm∼1430.7 ㎰/nm의 범위에서 분산 값을 제어할 수 있었다. 그리고 중심 파장의 이동은 0.03 nm미만이었다.