• 제목/요약/키워드: Feeder voltage

검색결과 141건 처리시간 0.021초

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.

국제 표준에 따른 저압간선 전압강하 계산시 적용 방법 고찰 (Application Method Analysis at Voltage Drop Calculations on Low Voltage Feeder by IEC Standard)

  • 김기현;이주철;최영규;김한수;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.53-58
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest application method and review items at calculations for voltage drop calculations on low voltage feeder by IEC 60364, BS 7671 standard and Consumer's Electrical Installation Guide.

Voltage Impacts of a Variable Speed Wind Turbine on Distribution Networks

  • Kim, Seul-Ki;Kim, Eung-Sang
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.206-213
    • /
    • 2003
  • The main purpose of this paper is to present a simulation model for assessing the impacts of a variable speed wind turbine (VSWT) on the distribution network and perform a simulation analysis of voltage profiles along the wind turbine installed feeder using the presented model. The modeled wind energy conversion system consists of a fixed pitch wind turbine, a synchronous generator, a rectifier and a voltage source inverter (VSI). Detailed study on the voltage impacts of a variable speed wind turbine is conducted in terms of steady state and dynamic behaviors. Various capacities and different modes of variable speed wind turbines are simulated and investigated. Case studies demonstrate how feeder voltages are influenced by capacity and control modes of wind turbines and changes in wind speed under different network conditions. Modeling and simulation analysis is based on PSCAD/EMTDC a software package.

Parts Feeder의 진동특성에 관한 연구(제2보) -Bowl의 재질에 관한 진동특성- (A Study on the Vibration Characterrst ics for Parts Feeder(2nd Report) -Vibration Characteristics due to Bowl Materials-)

  • 김순채;김희남;권동호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.597-601
    • /
    • 1994
  • In this paper, we have describes about the reationships between a core gap and a feeding velocity, an amplitude and the core gap by the exciting forc, the parts movement and a bowl materials, and the feeding veocity and the parts in the parts feeder. The main results as compared with the stainless and the aluminum materials are as follow : 1) The mean feeding velocity by bowl material shown more relative proportion in the STS304 to the exciting voltage than the C%AV 2) IN the exciting voltage, the response time for the aluminum material is slow, but the stainless is sensibility. 3) An exciting voltage is rised by an increase of the weight, but an amplitude has been in the range between 23 .mu.m through 40 .mu. m.

  • PDF

Parts Feeder의 진동특성에 관한 연구 (A Study on the Vibration characterrstics for Parts Feeder)

  • 김순채
    • 한국생산제조학회지
    • /
    • 제5권1호
    • /
    • pp.17-26
    • /
    • 1996
  • In this paper, we have studied about the relationships between a core gap and a feeding velocity, an amplitude and the core gap by the exciting force, the parts movement and a bowl materials, and the feeding velocity and the weight of the parts in the parts feeder. The obtained are as follow : 1) Optimal condition of mean feeding velocity is speeded up largely when the core gap is in 0.6mm. 2) It can be safe to say that the relation between the feeding velocity and the exciting voltage relay on the core gap. 3) An exciting voltage is rised by an increase of the weight, but an amplitude has been in the range between 23$mu extrm{m}$ through 40${\mu}{\textrm}{m}$.

  • PDF

변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 (Current Limiting and Voltage Sag Compensation Characteristics of Flux-Lock Type SFCL Using a Transformer Winding)

  • 고석철
    • 한국전기전자재료학회논문지
    • /
    • 제25권12호
    • /
    • pp.1000-1003
    • /
    • 2012
  • The superconducting fault current limiter (SFCL) can quickly limit the fault current shortly after the short circuit occurs and recover the superconducting state after the fault removes and plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the flux-lock type SFCL with an isolated transformer, which consists of two parallel connected coils on an iron core and the isolated transformer connected in series with one of two coils, has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. The current limiting and the voltage sag compensating characteristics of a SFCL using a transformer winding were analyzed. Through the analysis on the short-circuit tests results considering the winding direction of two coils, the SFCL designed with the additive polarity winding has shown the higher limited fault current than the SFCL designed with the subtractive polarity winding. It could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

병렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 분석 (Analysis on Current Limiting and Voltage Sag Compensating Characteristics of a SFCL using Magnetic Coupling of Parallel Connected Two Coils)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.159-163
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the SFCL using magnetic coupling of two coils with parallel connection has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. In this paper, the current limiting and the voltage sag compensating characteristics of a SFCL using magnetic coupling of parallel connected two coils were analyzed. Through the analysis on the experimental results considering the winding direction of two coils, the SFCL designed with the additive polarity winding was shown to have the higher limited fault current than the SFCL designed with the subtractive polarity winding. In addition, it could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

피더모델링을 이용한 배전계통 재구성 (Distribution Network Reconfiguration Using Feeder Modeling)

  • 김세호;안진오;이수묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1156-1158
    • /
    • 1998
  • This paper Presents two distribution-feeder models to simplify complicated distribution system calculations. These equivalent models are developed to simulate the total series voltage drop at the end of the given feeder and the total line loss of the given feeder accurately. In addition, the proposed models are bidirectional. This means that power infeed can be at either end and the model is accurate. Also, it is shown that the proposed models are suitable for network reconfiguration.

  • PDF

직류전기철도 시스템에 있어서의 변전소 송출전압에 따른 회생전력유효이용 (An Effective Utilization of Regenerative Power According to the Output Voltage of Substations in the DC Electric Railways)

  • Kim, Yang-Mo
    • 대한전기학회논문지
    • /
    • 제39권2호
    • /
    • pp.149-156
    • /
    • 1990
  • In DC electric railway systems, the feeding currrnt is not permitted to flow backward in almost all the substations and the pantograph voltages at the regenerating cars rise extremely by the voltage drop of the resistance of the feeder line. In order to prevent the overrise of the pantograph voltage in power regenerating cars, the squeezing circuits for the regenerative current are equipped and this leads to double losses, which are an extra worn-out of the brake-shoes and an ineffective use of regenerative power. In this study, the insertion of resistors in the feeder line system is proposed as a possible method for the effective utilization of the regenerative power in the electric railways. Also it is investigated how the output voltages of substations affect the effective use of regenertive capability. The investigation results show that the energy savings and the reduction of the worn-out of the brake-shoe can be achieved at the same time by the insertion of resistors in the feeder line system.

  • PDF

Investigation of On-line Monitoring Method on 1500 V Direct Current Cable of Subway

  • Shen, Xiaojun;Jiang, Xiuchen;Yi, Zeng
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.247-251
    • /
    • 2006
  • The traction DC feeder cable is one of the key devices for the safety operation of subway system, but for low voltage DC feeder cable (<3000 V) for subway, little attention has been paid by investigators on its online monitoring technology. With an introduction of cable laying and operation environment for the cable, this paper investigated the on-line monitoring technology of 1500 V DC feeder cable of subway. Firstly, in the text, the fault model of 1500 V DC cable was proposed based on the analysis of the fault type of the DC feeder cable, and then put forward synthetically on-line monitoring discharge signal and DC leakage current signal to assess DC feeder cable insulating state. The results of laboratory experiment prove that the proposed methods are feasible and can be implemented on-line monitor on DC feeder cable of subway.