• 제목/요약/키워드: Feeder current

검색결과 154건 처리시간 0.048초

Investigation of On-line Monitoring Method on 1500 V Direct Current Cable of Subway

  • Shen, Xiaojun;Jiang, Xiuchen;Yi, Zeng
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.247-251
    • /
    • 2006
  • The traction DC feeder cable is one of the key devices for the safety operation of subway system, but for low voltage DC feeder cable (<3000 V) for subway, little attention has been paid by investigators on its online monitoring technology. With an introduction of cable laying and operation environment for the cable, this paper investigated the on-line monitoring technology of 1500 V DC feeder cable of subway. Firstly, in the text, the fault model of 1500 V DC cable was proposed based on the analysis of the fault type of the DC feeder cable, and then put forward synthetically on-line monitoring discharge signal and DC leakage current signal to assess DC feeder cable insulating state. The results of laboratory experiment prove that the proposed methods are feasible and can be implemented on-line monitor on DC feeder cable of subway.

부하 특성에 따른 교류 급전시스템에서의 보호방식 연구 (A Study on Protection system to the Load Characteristics on the AC Feeder System)

  • 정호성;한문섭;이장무;김주락
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1370-1372
    • /
    • 2004
  • At present. distance relay and ${\Delta}I$ current increment relay are used as primary and secondary protection in the AC feeder system. However. electric railway vehicles according to power electronic's development had developed resistance control, thyristor phase control and PWM control system. and operation of train is increasing in a feeder section. Therefore this paper analyzes the load characteristics and situation of relay's maloperation caused by load current increase, harmonics, regenerative braking current and operation of the different vehicles in same feeder section. Based on this analysis. this paper proposes consideration items for relay correction and advanced adaptive relay that can change operation area according to load current.

  • PDF

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

중소형 아파트에서의 전력간선 부하 실태 (Current Status of the Feeder Demand Factor in Small Size Apartments)

  • 이기홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.116-118
    • /
    • 2004
  • This paper gives a measurement data of the feeder demand factor in small size apartments. The power load measurement data of the feeder shows that the feeders have $10{\sim}30[%]$ margin in capacity. But this margin is not enough to keep up with the trend of power consumption increase from long term standpoint. So it is necessary to measure the feeder power load periodically for the purpose of optimal feeder capacity estimation

  • PDF

전기철도 AT급전계통 전력해석을 통한 실계통의 단락전류 분석 (The Analysis of Short Current on Actual System through Power Analysis of AT Feeder System for Electric Railway)

  • 정노건;정호성;구경완;김재문
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1582-1587
    • /
    • 2014
  • In this paper, we perform a modeling for the AT Feeder system in AC electric railway and we utilize the power EMTDC program to implement about AT feeder system modeling. In addition, we study the impedance characteristics of the AT feeder system and calculated fault current and impedance according to the distance due to fault accident. Based on it's result, fault current are compared between calculating the value and simulation value in EMTDC modeling. Impedance of power system is Largest at the middle point of the system and is smallest near autotransformer, and then showed that the fault current is inversely proportional to impedance characteristics.

배전용 변전소 주변압기 중성점에 초전도 전류제한기 적용시 전류제한특성 분석 (Limiting Current Characteristics using Superconducting Fault Current Limiter on Neutral Line of Main Transformer in Distribution Substation)

  • 김진석;김명후;유일경;문종필;임성훈;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.14_15
    • /
    • 2009
  • In this paper, the effect of SFCL which was applied on neutral line of main transformer in distribution substation was analyzed in addition to the position of SFCL among some cases which are studied. The result about the limiting current was compared with the effect with SFCL applied on feeder. The limiting current characteristics are similar to the effect of SFCL on feeder. Therefore, this application of SFCL is required to protection coordination such as SFCL is applied on feeder.

  • PDF

급전선로에 설치되어 있는 피뢰기의 누설전류 측정과 관리방안 (Leakage Current Measurement and Management of Arresters Installed in Feeder Lines)

  • 한주섭;서황동;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.819-824
    • /
    • 2005
  • This paper describes the measurement result of leakage current flowing arresters connected in feeder lines to propose an optimal management method. Twenty seven arresters set in seven areas were analyzed on a regular basis for 4 months. The results showed that the RMS and the peak value of the total leakage currents for soundness arresters were a range of $200uA{\sim}00uA$. respectively. During the period of measurement, the magnitude of the leakage current didn't show conspicious changes and there were impossible places to analyze arrester's status due to including high THD rate in a feeder line, From the study, leakage current measurement has to be performed at a condition without running an electric train in the line, and the allowable RMS value of soundness arrester is bellow 600uA.

  • PDF

웨이블릿 변환을 이용한 고장과 Variation의 유형 구분 알고리즘 개발 (Development of the Algorithm for Discriminating Faults from Variation using Wavelet Transform)

  • 서훈철;이순정;김철환
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1460-1466
    • /
    • 2011
  • This paper proposes the algorithm for discriminating faults from the variation due to the operation of non-linear components to prevent the mal-operation of protection relay in the distribution system. An IEEE 13 node test feeder is modeled to analyze the characteristics of the fault and each variation using EMTP-RV. Simulations with various operating conditions of transformers, non-linear loads, and unbalanced loads are performed using the test feeder model. Based on simulation results, the wavelet transform is adopted to analyze the current waveforms from the faults and variations to find out the differences between them and the algorithm for discriminating faults from the variation is proposed. The proposed algorithm is verified by using the current waveforms simulated in the KEPCO's distiribution system and IEEE 13 node test feeder.

고장전류 통전정보를 갖는 Fault Indicator를 이용한 선로자동화 실증시험 (The Field Test of Feeder Automation using Fault Indicator having the information of fault current flowing)

  • 허복남;박상만;이중호;조남훈;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.758-760
    • /
    • 1997
  • For feeder automation function, we must have Fault Indicator with the information of fault current flowing inside automatic feeder switches. In this paper, we introduce the algorithm of feeder automation, the theory of fault indicator, the result with some troubles of field test in real distribution system and contents of improvement.

  • PDF