• Title/Summary/Keyword: Fe(Ⅱ)정량

Search Result 265, Processing Time 0.024 seconds

Detection and Determination of the Peroxyl Radical in the Photolysis with TiO2 (TiO2와의 광반응하에서 생성되는 페록시라디칼(HO2・/O2-)의 검출 및 정량화)

  • Kwon, Bumgeun;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.7
    • /
    • pp.45-49
    • /
    • 2010
  • We have developed and demonstrated the use of a new kinetic method as an analytical tool for the measurement of $HO_2{\cdot}/O_2{\cdot}^-$. This new method is based on the reduction of $Fe^{3+}$-Ethylene Diamine Tetra Acetate, EDTA) into $Fe^{2+}$-EDTA by $HO_2{\cdot}/O_2{\cdot}^-$ and the well-known Fenton-like reaction of $H_2O_2$ and $Fe^{2+}$-EDTA to yield the hydroxyl radicals ($OH{\cdot}$). Since this method for $HO_2{\cdot}/O_2{\cdot}^-$ shows high sensitivity and allows a simple calibration system, it can contribute significantly to understanding the basic functions of $HO_2{\cdot}/O_2{\cdot}^-$ in advanced oxidation processes for water treatment. Moreover, the present technique has the advantage of using inexpensive and easily available nonenzymatic reagents and of being insensitive to the moderate concentration of possible interferences often found in aqueous phase.

Quantitative Analysis of Zn-Fe Electroplated Steel Sheet by Glow Discharge Spectrometry (Glow Discharge 방출분광법에 의한 Zn-Fe 전기도금강판의 정량분석)

  • So, Jai-Chun;Chung, Sung-Wook;Lee, Do-Hyung
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.73-77
    • /
    • 1992
  • The quantitative analysis experiment of Zn-Fe electroplated steel was carried out by means of glow discharge spectrometry. The experimental results of chemical composition and coating weight of the Zn-Fe layer were compared with those obtained by the wet chemical analysis method. It has been found that those results obtained by two different methods agreed well with each other.

  • PDF

Selective Separation and Determination of Iron with Ion-Exchange Resins (이온교환수지에 의한 철의 선택적 분리 및 정량)

  • Yong Soon Chung;Dong Won Kim;Seung Ho Kim;Dai Woon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.45-54
    • /
    • 1987
  • Dowex 1-X8 resin ion exchanged with calcon carboxylic acid (CCA-Dowex 1-X8) and 2-methyl-8-hydroxyquinoline(MHQ) impregnated-Amberlite XAD-4 resin (MHQ-XAD-4) were examined for the separation and preconcentration of ferric ion from the various matrices. The stabilities of these resins were investigated, and their capacities on ferric ion were also measured. The effect of pH on the adsorption of ferric ion and matrix ions, such as Al(Ⅲ) and Ca(Ⅱ), was investigated to determine the optimun pH ranges. Separation and preconcentration of iron in aluminium foil and mineral water samples were studied by elution method with these resin columns. The recovered ions by 10ml of 2F nitric acid was determined by flame atomic spectrophotometry. SP-Sephadex C-25 column was used to separate ferrous and ferric ion in mineral water by stepwise elution with ferrozine and 1 % ascorbic acid-ferrozine solution. The concentrated and separated each ion could be determined spectrophotometrically at the analytical wavelenth of Fe(Ⅱ)-ferrozine complex (562nm).

  • PDF

Studies with $P^{32}$ Tracer on Laboratory Index of Available Phosphorus in Paddy Soil, Korea (II) ($P^{32}$ 추적자법(追跡子法)에 의(依)한 토양(土壤)의 유효인산정량법(有動燐畿定量法)에 관(關)한 연구(硏究) (II))

  • Lee, C.Y.;Park, Hoon
    • Applied Biological Chemistry
    • /
    • v.13 no.1
    • /
    • pp.73-79
    • /
    • 1970
  • The present study has been undertaken to see if any proper measure be found for the determination of available phosphorus by chemical extraction on the basis of A-values as the standard. The results obtained are described as follows. 1. Since A-value of the samples under study showed a significant correlation with Fe-P at 1% level. The available phosphorus in the present paddy soils was considered to be affected by Fe-P. 2. Six methods for chemical extraction were not correlated with the determination of Fe-P, proving them inadequate for the quantitative measurement of available phosphorus. 3. Adequate method for extracting available phosphorus in paddy soils should rest on the measurement of the reduction intensity of Fe-P. The extractable intensity was estimated to be 270 ppm in average. 4. Bray No. 2-P showed significant correlation with Lancaster-P, Spurway-P, Truog-P, and (Ca+Al)-P at 5% level. Olsen-P and Lancaster-P indicated significant correlation with Al-P and Spurway-P with Ca-P respectively at 1% level.

  • PDF

Quantitative analysis of iron ore sinter by X-ray powder diffraction method (X-선 분말 회절법을 이용한 소결광 구성광물상의 정량분석)

  • 김덕남;김형순
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.3
    • /
    • pp.264-270
    • /
    • 2000
  • Quantitative analysis of iron ore sinter consisting of hematite, magnetite, calcium ferrite and slag was investigated by X-ray internal standard method. After selecting NaF and $SiO_2$as internal standard materials, the calibration curves were determined and were applied to quantitative analysis of the internal standard method. Calcium ferrite was identified as a solid solution of CaO.$2Fe_2$$O_3$with 7 wt% and 3 wt% solubility of $AI_2$$O_3$and $SiO_2$, respectively. The maximum deviation of quantitative analysis of synthetic iron ore was about $\pm$5 wt%. The contents of each mineral calculated in industrial sinter were 27~40 wt% of hematite, 20~30 wt% of magnetite, 22~33 wt% of calcium ferrite and 10~20 wt% of slag.

  • PDF

Differential Pulse Voltammetric Determination of Iron(III) Ion with a Sodium Dodecyl Sulfate Modified Glassy Carbon Electrode (시차펄스전압전류법에서 도데실황산나트륨이 수식된 유리탄소전극에 의한 선택성 있는 철(III) 이온의 정량)

  • Ko, Young Chun;Kim, Jin Ah;Chung, Keun Ho
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.427-432
    • /
    • 1997
  • A selective method for the determination of iron(III) ion with a sodium dodecyl sulfate(SDS) modified glassy carbon electrode was proposed. It was based on the electrostatic attraction and complexation of the SDS modifier, $(DS^-)_n-Fe^{3+}$. The determination of iron(III) ion was performed by a differential pulse voltammetry(DPV), and the reduction peak potential of $(DS^-)_n-Fe^{3+}$ was +0.466(${\pm}0.002$)V vs. Ag/AgCl. For the determination of iron(III) ion, a linear calibration curve was obtained within the iron(III) ion concentration range of $0.50{\times}10^{-5}{\sim}10{\times}10^{-5}mol/L$, and the detection limit was $0.14{\times}10^{-5}mol/L$. $Cu^{2+}$, $Ni^{2+}$, $Co^{2+}$, $Pb^{2+}$, $Zn^{2+}$, and $Mn^{2+}$ showed little or no effect on the determination of iron(III) ion, respectively. But, ion such as each $CN^- $ and $SCN^-$ interfered seriously.

  • PDF

Variation of microstructures and magnetic properties of nanocomposite Nd-Fe-B alloys by small cobalt and dysprosium additions

  • Kim, Moon-Bae;Park, J. H.;Lee, D. H.;Taesuk Jang
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.240-241
    • /
    • 2002
  • Tetragonal 구조를 갖는 정량적 Nd$_2$/Fe$_{14}$B (~Nd$_{12}$Fe$_{82}$B$_{6}$) 화합물에서의 Nd 양보다 적은 양의 Nd를 함유하는 Nd-Fe-B 합금에서는, 일반적으로 입자크기가 큰 연자성 $\alpha$-Fe가 과다하게 존재하면서 외부에서 가해주는 자장에 대해 강자성 Nd$_2$/Fe$_{14}$B와 별개의 자기적 거동을 보여주기 때문에, 보자력이 아주 적어 실용성이 없다. 그러나 이러한 합금을 급랭응고하여 미세 결정화하거나, 비정질화한 후 적절히 열처리 해주면 a-Fe와 Nd$_2$/Fe$_{14}$B 입자가 나노화하면서 이들 사이에 상호교환작용이 일어나 등방성 상태에서도 M$_{s}$ /2 보다 큰 잔류자화와 함께 적절한 크기의 보자력도 얻을 수 있다. (중략중략

  • PDF

Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode (Nafion-ethylenediamine이 수식된 유리탄소전극에 의한 시차펄스전압전류법으로 철(II) 이온의 정량)

  • Kyong Wone Kim;Hee Cheol Kim;Sung-Hyun Kim;Byung Ho Park;Yeon Hee Kim;Kyong Nam Kim;Yong Chun Ko
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.115-120
    • /
    • 2003
  • Determination of iron(II) ion with a perfluorinated sulfonated polymer(nafion)-ethylenediamine(en) modified glassy carbon electrode was studied. It was based on the chemical reactivity of an immobilized layer(nafion-en) to yield complex $[Fe(en)_3]^{+2}$. The oxidation peak potential by differential pulse voltammetry(DPV) was observed at 0.340${\pm}$0.015 V(vs. Ag/AgCl). The linear calibration curve was obtained in iron(II) ion concentration range $5{\times}10^{-6}{\sim}0.2{\times}10^{-3} M(0.28{\sim}11.17\; mg/L)$, and the detection limit(3s) was $1.89{\times}10^{-5}$M(1.056 mg/L).

철 이온이 도입된 수산화인회석의 합성과 물성변화에 관한 연구

  • Jeong, Byeong-Hyeon;Gwon, Gi-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.285-285
    • /
    • 2013
  • 수산화인회석(Hydroxyapatite, HAP)은 인체 내 뼈와 치아의 주성분으로서 칼슘과 인산염으로 구성된 물질이다. 암모늄을 이용하여 pH를 조절함으로서 hexagonal 형태의 HAP를 수열합성법으로 합성하였다. XRD pattern을 통하여 수산화인회석의 결정구조를 확인하였으며, 전이금속 중의 하나인 Fe(III) 이온을 이온교환반응을 통하여 수산화인회석 표면에 도입하였다. ICP 측정을 통해 Fe 함량을 정량하였고 SEM과 TEM image를 통하여 크기와 형태를 관찰하였다.

  • PDF