• 제목/요약/키워드: Fault-prevention

검색결과 149건 처리시간 0.035초

Fault Tree Analysis(FTA)에 의한 Toluene저장 Tank의 폭발해석 (The Evaluation of Explosion For Toluene Storage Tank by Computer-Aided Fault Tree Analysis)

  • 정재희;이영섭
    • 한국안전학회지
    • /
    • 제3권2호
    • /
    • pp.5-16
    • /
    • 1988
  • This study is conducted to evaluate the explosion of tolune storage tank in the petrochemical plant by Fault Tree Analysis. The conclusions are as follows; 1) Fault Tree diagram and the required computer program for evaluation of explosion accident is developed. 2) The probability of the top event, explosion accident, is $1.5\;{\times}\;10^{-8}$ per year, so there is almost no possibility of explosion during the life cycle of tank. However, the probability of Gate 6 and Gate 7 is 8.8 per month, therefore, attention should be paid to them for accident prevention. 3) The number of minimal cut sets is 67 sets which are not calculated the probability of each set, because of the lack of computer capacity. All the minimal cut sets should be examined case by case. However, it is necessary to be paid attention to COM1, 126, 131, and COM4 in minimal cut sets, because the number of appearance is so high. 4) The number path sets is 70 sets which are not calculated the probability of each set, because of the lack of computer capacity. It is very useful to prepare safety checklist by using this minimal path sets. Also, the events which appear many times, 123, COM5, 139, 127 and 128, are very high in reliability.

  • PDF

SW-FMEA 기반의 결함 예방 모델 (A Defect Prevention Model based on SW-FMEA)

  • 김효영;한혁수
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제33권7호
    • /
    • pp.605-614
    • /
    • 2006
  • 성공적인 소프트웨어 개발은 QCD에 의해 결정되며, 그 중 Quality는 Cost와 Delivery를 결정하는 핵심요소이기도 하다. 그리고 소프트웨어의 규모와 복잡도가 증가함에 따라 quality의 조기 확보의 중요성이 점차 커지고 있다. 이러한 관점에서 개발 후 결함을 찾아내고 수정하는 것보다 결함예방을 위해 더 많은 노력을 기울여야 할 것이다. 결함 예방을 위해서는 peer review, testing과 같은 결함 식별활동과 함께 기존에 발생된 defect 에 대한 분석을 통해 발생 가능한 결함의 주업을 차단하는 활동이 필요하며, 이를 위해 기존의 품질 데이타의 조직화 및 활용이 필요하다. 소프트웨어의 품질 예방을 위한 방법으로 system safety 확보를 위해 사용되고 있는 FMEA를 활용할 수 있다. SW-FMEA(Software Fault Mode Effect Analysis)는 예측을 통해 결함을 예방하는 방법으로, 기존에는 요구사항 분석 및 설계 시 많이 활용되어 왔다 이러한 SW-FMEA는 개발 활동을 통해 측정되는 정보를 활용하여, 분석, 설계, 나아가 peer review나 testing 둥 개발 및 관리 활동에 적용하여 결함예방 (defect prevention) 의 수단으로 활용 할 수 있다. 본 논문에서는 기존에 시스템 분석, 설계에 focusing된 SW-FMEA를 변형하여 product 결합뿐 아니라, 개발과정 중 발생할 수 있는 fault를 줄일 수 있는 결함 예방 model을 제안한다.

전자파 측정을 이용한 폐쇄 배전반의 사고예방진단 기법에 관한 연구 (A Study on the Diagnostic Method for Fault Prevention Of Metal Clad Switchgear Using Electromagnetic Detection Techniques)

  • 김재철;서인철;김영노;전영재
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.29-37
    • /
    • 2002
  • 본 논문에서는 전자파 측정기법을 이용하여 부분방전 발생 전·후에 검출된 신호를 분석하여 폐쇄 배전반의 이상 징후를 상시 감시할 수 있는 사고 예방진단기법을 제시하였다. 폐쇄 배전반의 정상 및 이상상태 판단을 위해 배전반 내부 및 외부에 헬리컬 안테나를 설치하여 이들 안테나에서 검출된 부분방전 발생 전·후의 신호를 주파수 스펙트럼 분석을 통해 크기를 비교 분석하였다. 본 논문에서는 부분방전 발생 전·후에 폐쇄 배전반 내부 및 외부에 설치된 안테나에서 검출된 신호들을 이용하여 정상상태 및 이상상태를 판별하는 방법을 적용하여 좋은 결과를 얻었으며, 향후 폐쇄 배전반의 절연 상태 감시 및 사고예방에 효율적으로 적용할 수 있으리라 기대된다.

고정밀 전류센서를 이용한 이중 차단용 전기화재 방재장치에 관한 연구 (A Study on Electrical Fire Disaster Prevention Device used in Double Circuit Break)

  • 박동필;곽동걸;정도영;김춘삼;신호준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2102-2103
    • /
    • 2008
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a electrical fire disaster prevention device(EFDPD) for a RCD trip or a self circuit-breaking function on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

갱폼 재해의 FTA를 통한 정량적 위험성 산정에 관한 연구 (Quantitative Risk Assessment based on Fault Tree Analysis for Gangform Accident)

  • 함영종;기정훈;박종일
    • 한국안전학회지
    • /
    • 제35권4호
    • /
    • pp.40-47
    • /
    • 2020
  • Although gangform has good workability due to the integration of outer wall forms and working platforms, 22 workers were died from 21 gangform related accidents during 2012 to 2016. Quantitative risk assessment is required for evident based prevention measure selection. In this study, based on 52 accident data from 2004 to the first half of 2019, FTA is conducted for probabilities of direct causes and their contribution to accidents. Three stages are considered; gangform installation, dismantling and lifting, and using. The effectiveness of countermeasures is evaluated through minimum cut set, RAW and RRW. Complete assembly of gangform on the ground level, detailed planning, and fall prevention device are suggested as prevention measures for installation, dismantling and lifting, and using stages, respectively.

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

등호제약조건을 이용한 계통 해석 및 고장판단 계산 구현 (Calculation of Network Analysis and Fault Decision using Equality Constraint Condition with MATLAB)

  • 양민욱;김건중;황인준
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2101-2106
    • /
    • 2009
  • The power system state estimation and prediction are very important for operation. Because that accidents of the Power system are the cause that many devices and etc are damaged. Currently, almost every power systems have 2nd,3rd back-upsystem for prevention of accident. But prevention of accident by miss-operation, due to operator or miss data, has not acounter plan. Because, we need to estimate the power system for correcting miss data and preventing miss operation by operator. We suggest algorithm for integrity of power system network data.

다양한 지질환경에서 지하수의 수리화학 및 자연방사성물질 산출특성 (Hydrochemistry and Occurrences of Natural Radioactive Materials from Groundwater in Various Geological Environment)

  • 정찬호;이유진;이용천;김문수;김현구;김태승;조병욱;최현영
    • 지질공학
    • /
    • 제26권4호
    • /
    • pp.531-549
    • /
    • 2016
  • 화강암, 화강편마암, 변성퇴적암류와 같이 다양한 지질환경에서 지하수내 자연방사성물질인 우라늄과 Rn-222의 산출특성에 대한 지하수의 수리화학적 영향, 지질과의 상관성, 단층대의 영향 등에 대해서 알아보고자 하였다. 이 연구를 위하여 영동지역을 대상으로 2차례에 걸쳐 지하수 49점, 지표수 4점을 채취하였다. 지하수내 우라늄과 지표 암석과의 상관성을 알아보기 위해 감마스펙트로메트리를 이용하여 40지점에서 지표방사능을 측정하였다. 지하수 화학적 유형 $Ca-HCO_3$, $Na-HCO_3$, $Ca-HCO_3(SO_4+NO_3)$등 3가지 유형을 보인다. 환경부 권고치인 우라늄 $30{\mu}g/L$를 초과하는 지하수는 총 49지점 중 2점이며, Rn-222의 경우 미국 EPA 기준치인 148 Bq/L를 초과하는 지하수는 총 40지점중 11점이다. 초과하는 지하수는 주로 화강편마암과 흑운모편마암 지질과 지질경계부에 분포한다. 지표방사능 세기와 지하수내 우라늄함량과는 뚜렷한 상관관계를 보여지 않는다. 아울러 $N45^{\circ}E$ 방향의 주향이동단층인 영동단층은 $82^{\circ}$의 고경도로 상반에 해당되는 화강암 및 화강편마암지역에서 고함량의 우라늄과 Rn-222가 산출되며, 하반에 해당되는 퇴적암지역에는 고함량의 지하수가 확인되지 않는데, 이와 같은 뚜렷한 차이는 지질의 영향과 더불어 단층대가 방사성물질의 이동 및 확산을 차단시키는 역할에도 원인이 있을 것으로 추정된다.

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발 (Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line)

  • 곽동걸;신미영;정도영;김효진;백성현;최병섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF