• Title/Summary/Keyword: Fault line

Search Result 1,138, Processing Time 0.024 seconds

A Study on the On-Line Fault Diagnosis and Restorative Control Expert System for a Substation Simulator (변전소 시뮬레이터의 온라인 고장진단 및 복구제어 전문가 시스템에 대한 연구)

  • Lee, H.J.;Chung, S.J.;Lim, C.H.;Cho, K.R.;Shin, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.110-112
    • /
    • 1999
  • Recently the substation automation is actively researched at each country. Since the substation automation is an integrated system that consist of electrical, electronic and computer technologies, performance evaluation is very important to inspect the developed system's applicable possibility for real power system. Most studies are verified using computer simulation, because it is hard to apply them to real power systems. Therefore development of a substation simulator is necessary for the performance evaluation of many application systems such as operator aid system. This paper introduces a substation simulator. An intelligent fault diagnosis and restorative control expert system is also introduced UDP/IP is applied as a protocol for data transport between expert system and SC(station computer). As to the Graphic User Interface, C++ Language and Visual Basic is used in the Windows NT operating system together with four Pentium II systems.

  • PDF

Operational characteristic of flux-lock type HTSC-FCL (자속구속형 고온초전도 전류제한기 동작 특성)

  • Lim, Sung-Hun;Choi, Hyo-Sang;Kang, Hyeong-Gon;Ko, Seok-Cheol;Lee, Jong-Hwa;Choi, Myung-Ho;Song, Jae-Joo;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.20-23
    • /
    • 2003
  • The operational characteristics of flux-lock type high-Tc superconducting fault currentlimiters(HTSC-FCLs) was described and currents equation at each coil was derived from equivalent circuit. $YBa_{2}Cu_{3}O_{7-x}$(YBCO) thin film was used as the current limiting elements of the flux-lock type HTSC-FCL, which were fabricated by etching the YBCO thin film into 2 mm wide and 420 mm long meander line consisting of foureen stripes with different length. The 2nd peak on the current of coil 2 after a fault disappeared by current of the 3rd winding, which was installed in the flux-lock type HTSC-FCL.

  • PDF

An Intelligent Power Transformer Protective Relaying Algorithm Based on Furzy Decision-Making (Fuzzy Decision-Making을 이용한 지능형 변압기 보호 계전 알고리즘)

  • Lee, S.J.;Kang, S.H.;Choe, Myeon-Song;Kim, S.T.;Kang, D.H.;Kim, K.H.;Kim, I.D.;Jang, B.T.;Lim, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.891-893
    • /
    • 1997
  • In this paper an intelligent power transformer protective relaying algorithm based on Fuzzy Decision-Making is presented. The introduced protection algorithm contains several internal fuzzy rule-bases including bpa(Basic Probability Assignment: m) which are subject to off-line pre-installation by the analysis of the transformer transient characteristics for detecting the internal fault. Dempster-Shafer's rule of combination is used for the inference method with rules to decide the situation of a transformer, The proposed algorithm immunes to the saturation of transformer, inrush conditions, over excitation, and external fault. The included results of testing show practically sufficient sensitivity and selectivity of the proposed algorithm.

  • PDF

A DFT Based Filtering Technique to Eliminate Decaying dc and Harmonics for Power System Phasor Estimation

  • Oh Yong- Taek;Balamourougan V.;Sidhu T.S.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.138-143
    • /
    • 2005
  • During faults, the voltage and current signals available to the relay are affected by the decaying dc component and harmonics. In order to make appropriate and accurate decisions, most of the relaying algorithms require the fundamental frequency phasor information that is immune to decaying dc effect and harmonics. The conventional Fourier ph as or estimation algorithm is affected by the presence of decaying-exponential transients in the fault signal. This paper presents a modified Fourier algorithm, which effectively eliminates the decaying dc component and the harmonics present in the fault signal. The decaying dc parameters are estimated by means of an out-of-band filtering technique. The decaying dc offset and harmonics are removed by means of a simple computational procedure that involves the design of two sets of Orthogonal digital OFT filters tuned at different frequencies and by creating three off-line look-up tables. The technique was tested for different decay rates of the decaying dc component. It was also compared with the conventional mimic plus the full cycle OFT algorithm. The results indicate that the proposed technique has a faster convergence to the desired value compared to the conventional mimic plus OFT algorithms over a wide range of decay rates. In all cases, the convergence to the desired value was achieved within one cycle of the power system frequency.

On a Design and Implementation Technique of a Universal ATPG for VLSI Circuits (VLSI 회로용 범용 자동 패턴 생성기의 설계 및 구현 기법)

  • Jang, Jong-Gwon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.3
    • /
    • pp.425-432
    • /
    • 1995
  • In this paper we propose a design and implementation technique of a universal automatic test pattern generator(UATPG) which is well suited for VLSI digital circuits. UATPG is designed to extend the capabilities of the existing APTG and to provide a convenient environment to computer-aided design(CAD) users. We employ heuristic techniques in line justification and fault propagation for functional gates during test pattern generation for a target fault. In addition, the flip-flops associated with design for testability (DFT) are exploited for pseudo PIs and pseudo POs to enhance the testabilities of VLSI circuits. As a result, UATPG shows a good enhancement in convenient usage and performance.

  • PDF

Improvements in Design and Evaluation of Built-In-Test System (무기체계 정비성 향상을 위한 BIT 설계 및 검증 방안)

  • Heo, Wan-Ok;Park, Eun-Shim;Yoon, Jung-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.111-120
    • /
    • 2012
  • Built-In-Test is a design feature in more and more advanced weapon system. During development test and evaluation(DT&E) it is critical that the BIT system be evaluated. The BIT system is an integral part of the weapon system and subsystem. Built-In-Test assists in conducting on system and subsystem failure detection and isolation to the Line Replaceable Unit(LRU). This capability reduces the need for highly skilled personnel and special test equipment at organizational level, and reduces maintenance down-time of system by shortening Total Corrective Maintenance Time. During DT&E of weapon system the objective of BIT system evaluation is to determine BIT capabilities achieved and to identify deficiencies in the BIT system. As a result corrective actions are implemented while the system is still in development. Through the use of the reiterative BIT evaluation the BIT system design was corrected, improved, or updated, as the BIT system matured.

Analysis of Conductive Interference Around Substation Exclusively Fed by Cables Under Ground Fault Condition (도심지 변전소 지락사고시 인근 저항성간섭 영향 해석)

  • Choi Jong-kee;Lee Dong-il;Kim Jae-joon;Yoo Yeon-pyo;Jung Chang-soo;Kim Kyung-chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.592-596
    • /
    • 2005
  • Recently, substations have been constructed in GIS (Gas Insulated Switchgear) and indoor type because of the increasing difficulties of securing locations. In case of urban substations, it is also common that the substations are exclusively fed by underground cables. Sometimes, the infrastructures in urban area, such as communication facilities, are located near substations to be constructed. In this paper, we examined such a case that a branch office building of KT(Korea Telecom) was located near 154 kV underground GIS substation under construction with about 100 meters of the lateral distance between two facilities. GPR (Ground Potential Rise) at the substation and the transferred earth potential at the KT building through the earth in SLG (Single-Line-to- Ground) fault condition were investigated based on a series of computer simulations. The calculated earth potential at a distance of 100 m from the substation was below 120 V which satisfying the limit value of 650 V.

ON-LINE FAULT DIAGNOSIS IN THE LARGE POWER SYSTEM (계통 내 온라인 고장 진단 시스템 개발)

  • Seo, Gyu-Seok;Baek, Young-Sik;Kim, Jung-Nyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.122-124
    • /
    • 2004
  • Recently, power system is getting larger and more complex. When the complex power system has a problem, it is very difficult even for the experts to find out where the problem is and to make a timely decision by operators. There have been many studies on these problems but the results are not good enough for applying to real power system. Therefore power system operators always had to judge the exact state of power system and had to be preparative for the problems that can occur later. We developed new methods that can be applied to complex power system by dividing the system into small modules. By using 'module' we can combine small modules together to make complex power systems and the knowledge base that is applied to fault diagnosis system. As a result, compared to previously developed diagnosis products, operational time has shortened, and the knowledge base becomes simpler and clearer, which made online usage capable. This system can be used as a complementary measure that helps the operator from making any mistakes.

  • PDF

An Integrated Diagnostic System Based on the Cooperative Problem Solving of Multi-Agents: Design and Implementation

  • Shin Dongil;Oh Taehoon;Yoon En Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.28-34
    • /
    • 2004
  • Enhanced methodologies for process diagnosis and abnormal situation management have been developed for the last two decades. However, there is no single method that always shows better performance over all kinds of diagnostic problems. In this paper, a framework of message-passing, cooperative, intelligent diagnostic agents is presented for improved on-line fault diagnosis through cooperative problem solving of different expertise. A group of diagnostic agents in charge of different process functional perform local diagnoses in parallel; exchange related information with other diagnostic agents; and cooperatively solve the global diagnostic problem of the whole process plant or business units just like human experts would do. For their better understanding, sharing and exchanging of process knowledge and information, we also suggest a way of remodeling processes and protocols, taking into account semantic abstracts of process information and data. The benefits of the suggested multi-agents-based approach are demonstrated by the implementations for solving the diagnostic problems of various chemical processes.

  • PDF

Stabilization Power Systems withan Adaptive Fuzzy Control (적응퍼지제어를 이용한 전력계통 안정화)

  • 박영환;박귀태
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.2
    • /
    • pp.117-127
    • /
    • 1998
  • Power systems have uncertain dynamics due to a variety of effects such as lightning, severe storms and equipment failures. The variation of the effective reactance of a transmission line due to a fault is an example of uncertainty in power system dynamics. Hence, a robust controller to cope with these uncertainties is needed. Recently, fuzzy controllers are becoming quite popular for robust control due to its potential of dealing with uncertain systems. Thus in this paper we design an adaptive fuzzy controller based on an input-output linearization approach for the transient stabilization and voltage regulation of a power system under a sudden fault. Also this paper proposes a fuzzy system that estimates the upper bound of uncertain term in the system dynamics to guarantee the Lyapunov stability. Simulation results show that good performance is achieved by the proposed controller.

  • PDF