가공 배전선로 중성선과 가공지선 겸용시의 임펄스 특성 연구 (The Study on the Impulse Characteristic of Secondary Arresters in Power Distribution System)

  • 강문호;김동명;송일근;천성남
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.297-299
    • /
    • 2004
  • In multi-ground distribution system, overhead ground wire and neutral wire are parallel connected to offer the electrical power energy and protect damage of lightning strokes. Therefore a case where the two wires become single wire, the power company can get the benefit such as installation cost saving and line fault protection by simplify of distribution line. In this paper we describe the result of impulse test in both system ; one is the present power system the other is unified power system parallel connected overhead ground wire and neutral wire. As a result of this impulse test, the present power system get lower impulse voltage than the unified power system.

  • PDF

PSCAD를 이용한 상시 루프배전시스템의 보호계전기 모델 (A PSCAD Modeling of Protection Relay of On-Line Distribution System)

  • 김진수;박진현;조보현;문원식;조성민;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.406-407
    • /
    • 2011
  • The closed-loop distribution system is more flexible and more reliable than radial system. If any type fault occurs, the reliability of system can be better by providing electrical energy through another distribution line. However, it needs protection device coordination of different type. Typically, it is available by using directional overcurrent relay (67). This paper gives a solution about loop protection relay modeling which can be used by the simulation tools.

  • PDF

국내에서 발생한 낙뢰고장 분석을 통한 직격뢰 및 역섬락 고찰 (Consideration on shielding failure and back flashover through lightning fault analysis within the country)

  • 최한열;민병욱;박순규;이봉희;구성완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.280_281
    • /
    • 2009
  • The past 3 years study on the lightning faults data shows that the main reason is shielding failure rather than back flashover. Accordingly, we need to thoroughly consider about shielding failure angle of tower. Also, transmission line damage caused by shielding can be minimized if we avoid the steep slope area as a transmission line route.

  • PDF

PSCAD를 이용한 송전용 차단기 1상 개방사고 분석 (Analysis of the Effect of Open Phase Fault for Line Circuit Breaker Using PSCAD)

  • 이남형;최형철;김현일;옥연호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.181_182
    • /
    • 2009
  • Some phenomena occurred when one phase of the line circuit breaker was opened while a generator was operating to connect with the power grid were simulated by PSCAD/EMTDC and the analysis for the reason of operation and non-operation of protective relay will contribute to prevent spreading damage when same prospective faults occur.

  • PDF

배전용 변전소 주변압기 중성점에 초전도 전류제한기 적용시 전류제한특성 분석 (Limiting Current Characteristics using Superconducting Fault Current Limiter on Neutral Line of Main Transformer in Distribution Substation)

  • 김진석;김명후;유일경;문종필;임성훈;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.14_15
    • /
    • 2009
  • In this paper, the effect of SFCL which was applied on neutral line of main transformer in distribution substation was analyzed in addition to the position of SFCL among some cases which are studied. The result about the limiting current was compared with the effect with SFCL applied on feeder. The limiting current characteristics are similar to the effect of SFCL on feeder. Therefore, this application of SFCL is required to protection coordination such as SFCL is applied on feeder.

  • PDF

진동측정에 의한 전동공구 양산라인의 품질관리 자동화 (Automatic Q.C. of Electric Grinder using Vibration Signal)

  • 이봉현;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.173-178
    • /
    • 1998
  • An automatic Q. C. tester for a production line of electric grinder is developed using vibration signals. The methods of measuring and analyzing the vibration signals are found through several experiments at laboratory and production line. The experiments show that checking a vibration signal at running condition only, without any sound signal, is enough to judge whether the product is good or not. The Q. C. tester is made of accelerometer and PC. Measured vibration signal using accelerometer is transmitted to PC through A/D board. Vibration level are calculated using FFT algorithm in PC for already selected five frequency bands, which can specify the cause of fault. The Judging criteria of vibration levels of each bands are decided through a lot of experiment with the comparison of manual judgement.

  • PDF

Nonlinear Feedback Linearization-H\ulcorner/Sliding Mode Controller Design for Improving Transient Stability in a Power System

  • Lee, Sang-Seung;Park, Jong-Keun
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.193-201
    • /
    • 1998
  • In this paper, the standard Dole, Glover, Khargoneker, and Francis (abbr. : DGKF 1989) H\ulcorner controller (H\ulcornerC) is extended to the nonlinear feedback linearization-H\ulcorner/sliding mode controller (NFL-H\ulcorner/SMC), to tackle the problem of the unmeasurable state variables as in the conventional SMC, to obtain smooth control as the linearized controller in a linear system, and to improve the time-domain performance under a worst scenario. The proposed controller is obtained by combining the H\ulcorner estimator with the nonlinear feedback linearization-sliding mode controller (NFL-SMC) and it does not need to measure all the state variables as in the traditional SMC. The proposed controller is applied as a nonlinear power system stabilizer (PSS) for the improvement of the power system damping characteristics of an single machine infinite bus system (SMIBS) connected through a double circuit line. The effectiveness of the proposed controller is verified by nonlinear time-domain simulation in case of a 3-cycle line-to-ground fault and in case of the parameter variations for the AVR gain K\ulcorner and for the inertia moment M.

  • PDF

FACTS 기기가 설치된 송전선로에서 거리계전기의 응동특성 (A Study of Distance Relay Characteristic of Transmission Line including FACTS Devices)

  • 정창호;서정남;방성원;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.31-33
    • /
    • 2000
  • This paper discusses the operational characteristic analysis of distance relay depending on the power system parameters in transmission line including FACTS devices. Distance relay requires protective coordination because the FACTS devices change power system parameters to increase power transmission capacity. In this paper, the dynamic operational characteristics of distance relay are analyed for the effect of fault resistance and operation mode of FACTS devices according to the installed points of these devices.

  • PDF

배전변압기 감시제어 기능이 통합된 지능형 배전자동화 시스템 개발 방향 (Development target of intelligent DAS with the function of distribution transformer monitoring)

  • 하복남;설일호;박신열;정영범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.554-556
    • /
    • 2005
  • Distribution Automation System (DAS) will provide supervision and remote control of switches and reclosers such as pole pounted switches and pad-mounted switchgears on high voltage distribution line. Kepco had developed basic function such as remote monitoring, remote control, remote measuring and remote setting at first. As a next step, Kepco has been developed diverse application programs such as single line diagram drawing program, relay coordination program, feeder reconfiguration program, over load elimination program, bad data detection program, section load management program, fault processing program and so on. Kepco is examining to develop more powerful functions for special specification of foreign distribution automation system. This paper explains what is the target for overseas DAS market.

  • PDF

상관계수 가중법을 이용한 커널회귀 방법 (Kernel Regression with Correlation Coefficient Weighted Distance)

  • 신호철;박문규;이재용;류석진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.588-590
    • /
    • 2006
  • Recently, many on-line approaches to instrument channel surveillance (drift monitoring and fault detection) have been reported worldwide. On-line monitoring (OLM) method evaluates instrument channel performance by assessing its consistency with other plant indications through parametric or non-parametric models. The heart of an OLM system is the model giving an estimate of the true process parameter value against individual measurements. This model gives process parameter estimate calculated as a function of other plant measurements which can be used to identify small sensor drifts that would require the sensor to be manually calibrated or replaced. This paper describes an improvement of auto-associative kernel regression by introducing a correlation coefficient weighting on kernel distances. The prediction performance of the developed method is compared with conventional auto-associative kernel regression.

  • PDF