• 제목/요약/키워드: Fault line

검색결과 1,139건 처리시간 0.022초

철도차량 모니터 장치의 지상장치 최적화 기법에 관한 연구 (Study for Optimized Depot System of Train Monitoring System)

  • 주해진;한정수;박성호;홍구선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.497-502
    • /
    • 2002
  • TGIS(Train General Information System) is monitoring Train status and analyzing fault happened. TGIS informed a lot of Passenger data, Driving data, Status data and Fault data to 'Depot'. For dealing them more properly, TGIS need specified data and specialized data handling method. This paper suggest Optimize data of Train Monitoring System and Apply that to Main Line Car.

  • PDF

전류 고조파 관찰을 통한 영구자석 동기전동기의 권선 단락 고장 진단 기법 (A Fault Detecting Scheme for Short-Circuited Turn in a Permanent Magnet Synchronous Motor through a Current Harmonic Monitoring)

  • 김경화;구본관;정인성
    • 전력전자학회논문지
    • /
    • 제15권3호
    • /
    • pp.167-178
    • /
    • 2010
  • 영구자석 동기전동기에서 고정자 권선의 단락으로 인해 발생하는 권선 고장을 동작 중 실시간으로 검출할 수 있는 고장 진단 기법을 제시한다. 제안된 기법은 고조파 분석을 통해 q축 전류의 2차 고조파를 관찰함으로서 이루어지며 고장이 없는 정상 조건에서의 고조파 데이터와 비교를 통해서 고장을 판별한다. 임의의 정상 동작 조건에서의 고조파 데이터는 선형 보간법과 몇 개의 사전 측정된 고조파 데이터를 통해서 구해진다. 제안된 고장 검출 기법의 타당성을 입증하기 위해 내부 고정자의 권선 단락이 가능한 전동기가 제작되었으며 전체 구동 시스템과 고조파 분석 알고리즘 및 고장 검출 알고리즘이 DSP TMS320F28335에 의해 구현되어 실험이 수행된다. 제안된 방법은 부가적인 진단 장비를 필요로 하지 않으며 정상 상태 조건만 만족된다면 동작 중 실시간으로 고장을 검출할 수 있다.

FPGA를 활용한 DC계통 고장진단에 관한 연구 (A Study on fault diagnosis of DC transmission line using FPGA)

  • 김태훈;채준수;이승윤;안병현;박재덕;박태식
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.601-609
    • /
    • 2023
  • 본 논문에서는 DC 계통의 지락고장시 고속 고장진단을 위해 FPGA를 이용한 인공지능기반 고장진단 방법을 제안한다. 인공지능 알고리즘을 고장진단에 적용시 많은 연산량과 대용량의 실시간 데이터 처리가 요구된다. 또한 DC 계통에서의 고장 및 사고는 고장 전류의 빠른 상승률로 인하여 DC 차단기가 고속 차단능력이 필요하다. 인공지능기반 고속 고장진단이 가능한 FPGA를 사용하여 DC 차단기가 더 빠르게 동작함으로써, DC 차단기의 차단용량을 줄일 수 있다. 따라서 본 논문에서는 Matlab Simulink를 이용하여 DC계통의 고장 모의를 통해 고장데이터를 수집하여 지능형 고속 진단 알고리즘 구현하였으며, FPGA에 지능형 고속고장 진단 알고리즘을 적용 및 성능검증을 하였다.

선박의 접지 시스템에서 지락 고장에 따른 대지 전압 변동 특성 (Characteristics of loci on Line-to-Earth Voltage according to Earth Fault in Earthing System for Ships)

  • 김종필;류기탁;이윤형
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.487-495
    • /
    • 2021
  • 선박에서 주로 사용하는 전압은 450[V], 6.6[kV], 11[kV]이며, 운항 중 전력계통의 안정성 확보를 위해 접지 시스템이 적용된다. 일반적으로 450[V]를 사용하는 저전압 선박은 비접지 시스템을 6.6[kV], 11[kV]를 사용하는 고전압 선박은 고저항 접지 시스템을 적용한다. 선박의 전력계통에서 지락 고장이 발생하면 건전상의 대지 전압이 선간전압 또는 그 이상으로 증가하고, 케이블의 절연에 과도한 충격을 주게 되므로 이를 분석하는 것은 매우 중요한 부분이다. 따라서 본 논문에서는 선박에서 주로 채택하고 있는 고저항 접지 및 비접지 시스템에 대해 지락 고장에 따른 선박 전력계통의 대지 전압의 변동 특성과 고장 상의 판단 방법을 대칭 좌표법을 이용하여 분석하고자 한다. 이를 위해 대칭 좌표법을 이용하여 대지 전압의 수학적 모델을 유도하고, 시뮬레이션을 위한 선박 전압은 6.6[kV]와 450[V]로 선정하였다. MATLAB을 이용한 시뮬레이션 결과 두 접지 시스템 모두 지락상 보다 위상이 120° 앞선 상의 대지 전압이 가장 높게 상승하였고, 이를 이용하여 고장 상을 정확하게 판단할 수 있음을 확인하였다.

PLC 고장허용에 대한 이중화 시스템 연구 (A Study on Redundancy System for Fault Tolerance of PLC)

  • 이석용;이홍규
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.47-52
    • /
    • 2000
  • 이중화 PLC 제어시스템은 높은 유용성과 고장허용을 목표로 사용되고 2채널(1-out-of-Z) 구조로 동기화된 마스터, 스탠바이 시스템으로 PLC의 고장허용 제어를 실현함으로써 기계, 플랜트의 연속운전을 실현하며 데이터 링 크는 마스터와 스탠바이 제어기로 연결되어 있다. 고장허용 제어시스템은 전체 제어시스템에서 최소한의 고장으로 손실을 감소시키고 고장발생시 공정의 연속적인 운전과 시스템의 중단없이 수리 및 점검올 가능하게 하여 생산손실을 최소화하며 전체 시스템에 대하여 신뢰도를 향상시키는것이다.

  • PDF

CT와 CCVT의 오차를 고려한 거리 계전기의 응동 분석 (Analysis of the response of a distance relay considering the errors of CT and CCVT)

  • 강용철;정태영;최재선;강해권;김광무;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.12-15
    • /
    • 2008
  • A distance relay has been widely used for transmission line protection. The distance relay detects a fault based on the calculated impedance i.e. the ratio of the voltage to the current measured from a current transformer (CT) and a coupling capacitor voltage transformer (CCVT), respectively. When a fault occurs and a CT saturates due to the magnitude of fault current, dc component, primary time constant, and the remanent flux of the iron core, the secondary current of a CT is distorted On the other hand, non-fundamental components generated during a fault can increase the error of a CCVT, particularly when a fault distance is short. The distortion of the current and voltage can cause mal-operation or the operating time delay of a distance relay. This paper describes the response of a distance relay considering the errors of a CT and a CCVT. The results indicate that the severe distortion of a CT and a CCVT have noticeable effect to a distance relay.

  • PDF

차단기 부담 평가지표의 가중치 산정에 따른 초전도 한류기 적용위치 분석 (Analysis on Application Location of SFCL according to Circuit Breaker Burden Index with Weight Factor Estimation)

  • 박한민;이형진;김진석;임성훈;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권7호
    • /
    • pp.47-53
    • /
    • 2015
  • As the industrial development in Korea, the power demand is rapidly increased. The power system has been extended and complicated to meet the power demand. However, the fault current increases because the structure of power system reduces the equivalent impedance. One of the solutions to reduce the fault current is Superconducting Fault Current Limiter(SFCL) and the researches of SFCL application have much conducted. In this paper, we used the Circuit Breker Burden Index(CBBI) to select application location of SFCL because the CBBI may consider a fault current of each line. In addition, this paper divided the weight factor used to calculate the CBBI on a case by case basis and analyzed this characteristics through experiment.

Fault Current Limiting Characteristics of Flux-lock Type SFCL with Several Secondary Windings

  • Lim, Sung-Hun;Park, Chung-Ryul;Han, Byoung-Sung;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권5호
    • /
    • pp.193-197
    • /
    • 2005
  • We investigated fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL), which consisted of a primary winding and several secondary windings connected in series between $high-T_C$ superconducting (HTSC) thin films. Each YBCO thin film has a 2 mm wide and 42 cm long meander line with 14 stripes of different length. The power imbalance due to the slight difference of Ie between YBCO current limiting elements causes the significant power burden on YBCO element with lower $I_C$. We confirmed from our experiments that the mutual coupling between the primary winding and secondary windings of the flux-lock type SFCL reduced the power imbalance between YBCO current limiting elements compared with the resistive type SFCL connected in series.

지락고장에 의해 금속제 유연전선관에 유도된 개폐서지전압의 특성 (Characteristics of the Switching Surge Voltages Induced at Metal Flexible Conduits Due to Ground Faults)

  • 이복희;신건진;박희열;엄상현;김유하
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.74-80
    • /
    • 2013
  • This paper presents the transient behavior of the switching surge voltages generated by interruption of DC ground fault currents flowing through metal flexible conduits. All fault circuits consist of line parameters such as resistance, inductance, capacitance and conductance. The use of nonmagnetic metal conduits should be taken into account in order to reduce the inductance of battery charger distribution circuits. The frequency-dependent circuit parameters of metal flexible conduits were measured. The switching surge voltages generated at the ground fault circuit consisted of steel-galvanized alloy and aluminium conduits were investigated. As a result, the impedances of metal flexible conduits are significantly increased over the range of the frequency above 10 kHz and the switching surge voltages generated along aluminium flexible conduit are lower than those along steel-galvanized alloy conduit when DC fault current is interrupted.