• Title/Summary/Keyword: Fatigue measurement

Search Result 460, Processing Time 0.025 seconds

A Comparison of Self-Reported Fatigue and Fatigue-Regulating Behaviors of Rheumatoid Arthritic Patients and Normal Persons (류마티스관절염 환자와 정상인의 피로도 및 피로조절행위 비교)

  • Jung, Bok-Hee;Kim, Myung-Ae
    • Journal of muscle and joint health
    • /
    • v.6 no.1
    • /
    • pp.51-72
    • /
    • 1999
  • The purpose of this study is to compar self-reported fatigue and fatigue-regulating behaviors of rheumatoid arthritic patients and normal persons. This study collected the data from 75 rheumatoid arthritic patents visited the departments of internal medicine or orthopedics of four general hospitals T-city and K-city by means of direct interview and questionnaires. in this study also collected data from 75 normal persons who had not been exposed to any other disease in T-city and K-city by means of direct interviews anti questionnaires which were conducted by two trained nurses. This experiment was conducted from August 1, 1998 to October 15, 1998. This study used both MAP(Multi-Dimentional Assessment of Fatigue) developed by Belza(1995) to measure fatigue and the measurement developed by Kwon, Young-Eun to investigate fatigue regulating behaviors. The collected materials were analyzed by means of descriptive statistics, t-test, and the ANCOVA according to the SPSS PC+ program. The findings are as follows : 1. There was the statistically significant difference(t =5.07, p=.000), between rheumatoid arthritic patients(32.76 points) and normal persons(25.81 points) in t-test comparison by group about fatigue. A fatigue degree of rheumatoid arthritic patient group was high in five kinds of lower realms such as common fatigue degree, fatigue severity to be experienced, distress due to fatigue, daily fatigue degree, and fatigue timing at the last week by dimension. 2. There was the significant difference in the number of fatigue-regulating behaviors between rheumatoid of fatigue arthritic patients(9.37 times) and normal persons (8.15 times), but there wasn't any significant difference in the efficiency between rheumatoid arthritic patients(2.85 points) and normal persons (2.78 points) This research suggests two kinds of things as follows : 1. It is necessary to develop an educational program for improving efficiency of fatigue-regulating behaviors as well as some nursing arbitration measures for reducing fatigue of rheumatoid arthritic patients. 2. It is necessary for the future studies to continuously grasp characteristics of fatigue by gender variable by selecting more rheumatoid arthritic male patients.

  • PDF

A Study on the Fatigue Strength Improvement of Welded Parts of SS400 Using the Shot Peening and PWHT Technique for Subway Cars (쇼트피닝과 후열처리에 의한 전동차용 SS400 용접부 피로강도 개선연구)

  • Kim, Jin-Hern;Kim, Hyun-Gyu;Goo, Byeong-Choon;Cheong, Seong-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.65-70
    • /
    • 2007
  • Welding is the most commonly used method to produce bogie and carbody of Electrical Multiple Units(EMU), because it increases the strength and lowers the weight of EMU. Since bogies are constantly exposed to repeated reacting load during acceleration and deceleration, it is also true that crack normally occurs at welding parts. In this study, we have investigated the fatigue strength of SS400 on welded parts in order to find efficiency of treatment after welding by shot peening and Post-Weld heat treatment(PWHT) with butt welded specimens. The results of fatigue test indicate that the measurement of base material specimen is 236MPa, welded specimen is 132MPa and the specimen of PWHT is 107MPa approximately. We concluded that the measurement of welded specimen and PWHT is approximately 44 and 54 percents lower than the base material specimen, respectively. Another finding is that the peened specimen is approximately 23 and 61 percents higher than the base material specimen in terms of the fatigue in strength of specimens.

  • PDF

An Automated System for Constant ${\Delta}K_{eff}$ Fatigue Crack Growth Testing through Real-time Measurement of Crack Opening Load (${\Delta}K_{eff}$ 제어 피로 균열 진전 시험 자동화 시스템에 관한 연구)

  • Shin, Sung-Chul;Song, Ji-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.447-452
    • /
    • 2001
  • An automated system is developed to perform fatigue crack growth tests under constant effective stress intensity factor range ${\Delta}K_{eff}$. In the system, crack length and crack opening load are measured in real-time by using the unloading elastic compliance method. The system consists of two personal computers, an analogue electrical subtraction circuit, a stepping motor, a stepping motor driver, a PIO board, and the application software used to integrate the whole system. The performance of the developed system was tested and discussed performing constant ${\Delta}K_{eff}$ crack growth tests on a CT specimen of 7075-T6 aluminum alloy. The performance of the system is found to be strongly dependent on the accuracy of measurements of crack opening load. Besides constant ${\Delta}K_{eff}$ testing, the system is expected to be successfully applied for automation of various fatigue tests.

  • PDF

Fatigue Crack Propagation Characteristics of Duplex-Stainless Steel Weldment (III) (2상계 스테인리스강 용접부의 피로크랙전파 특성 (III))

  • 이택순;권종완
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.901-910
    • /
    • 1989
  • Corrosion fatigue crack propagation behavior of duplex stainless steel weldments in substitute ocean water was investigated to evalulate effects of micro-structural change and residual stresses. Fatigue crack propagation rate was found influenced markedly .alpha./.gamma. phase ratio but little by residual stresses. Fatigue crack propagation rate is higher in the corrosive environment than in room atmosphere. The crack propagation rate estimated by the measurement of striation spacing was higher than that, obtained by crack length measurement in low .DELTK.K region. At hight .DELTK.K region, however, both crack propagation rates were found to be identical.

Development of Fatigue Scale of Private Security Guards (민간경비원의 피로도 척도개발)

  • Kim, Kyong-Sik;Park, Young-Man
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.175-185
    • /
    • 2014
  • This study is to develop a fatigue scale for the private security guard for a private security guard to effectively manage fatigue were tested for validity and reliability. To achieve that, this study employed purposive sampling to draw 300 samples among private security guards working for the security firms registered in Seoul District Police Office as of 2014, and used 259 samples for final analysis. Fatigue scale was developed on the basis of the scale development methods and procedures in previous studies. For data processing, SPSSWIN 18.0 program was applied to conduct exploratory factor analysis, reliability analysis, and correlation analysis, and AMOS 18.0 program was employed to conduct confirmatory factory analysis. This study came to the following conclusion. First, the validity of the fatigue measurement tool was high. In other words, content validity was high, and construct validity was also high. The factor loading of exploratory factor analysis was .452, and the standard value of confirmatory factor analysis was .403. Therefore, the tool satisfied the basis value of fit index. The sub categories of fatigue, finally drawn from validity test, were mental fatigue, nervous system dysfunction, physical deformity, and exhaustion. Secondly, the reliability of the fatigue measurement tool was high. In other words, according to item analysis, the correlation between items and their sub categories, and between items and total score was more than .602, relatively high. And the reliability coefficient (Cronbach's ${\alpha}$) was high, or more than .658. Fatigue Scale tool will be developed by private security guards in the present study is to measure the validity and reliability verification is clearly tired of the private security guards than the tools that are used in other studies in the existing area.

Development of Measurement Systems of Foot Pressure Distribution for Sensory-Feedback type FES System(SEFES) (감각귀환형 기능적 전기자극 시스템(SEFES)을 위한 발압력 분포 계측시스템의 개발)

  • Kim, J.M.;Kim, Y.Y.;Yang, K.M.;Ko, S.B.;Jeong, D.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.88-91
    • /
    • 1994
  • We develope a assistant system of foot pressure distribution for improvement gait Pattern, adapted working speed, and minimitation of muscle fatigue of the sensory feedback type FES system(SEFES). This measurement system consist of mat type pressure sensor with piezo electric films. The pressure data signal multiflexed input scanning method processed A/D conversion after two step amplify and integrate. Matrix sensor interface to PC for pseudo color display by level of Pressure distribution data. This measurement system clinically evaluated in hemiplegic patients. It has produced acceptable results with optimal location of the food sensor's pressure point and avoid the muscle fatigue.

  • PDF

Performance Monitoring and Load Analysis of Wind Turbine (풍력발전기의 성능 모니터링 및 하중분석)

  • Bae, Jae-Sung;Kim, Sung-One;Youn, Joung-Eun;Kyung, Nam-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.385-389
    • /
    • 2004
  • Test facilities for the wind turbine performance monitoring and mechanical load measurements are installed in Vestas 100 kW wind turbine in Wollyong test site, Jeju island. The monitoring system consists of Garrad-Hassan T-MON system, telemetry system for blade load measurement, various sensors such as anemometer, wind vane, strain gauge, power meter, and etc. The experimental procedure for the measurement of wind turbine loads, such as edgewise(lead-lag) bending moment, flapwise bending moment, and tower base bending moment, has been established. Strain gauges are on-site calibrated against load cell prior to monitoring the wind turbine loads. Using the established monitoring system, the wind turbine is remotely monitored. From the measured load data, the load analysis has been performed to obtain the load power spectral density and the fatigue load spectra of the wind turbine.

  • PDF

A Study on the Measurement of Plastic Zone Depth using TRIZ (창의적 문제해결 이론을 이용한 소성역깊이 측정에 관한 연구)

  • Lee, Dong-Woo;Joo, Won-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.62-66
    • /
    • 2008
  • Machine parts subjected to fluctuating or cyclic loads induce repeated stresses that often result in failure by fatigue. In such cases, the fatigue failures unfortunately sometimes occur. These may arise from a lack of knowledge with regard to the design, fabrication and operation of the machines or structures. The failure analysis provides valuable information regarding the prevention of similar failures. Furthermore, this information will be useful to improve or to develop new products. Failure stress analysis is classified into X-ray fractography. X-ray fractography has the limited applications because of material crystal size, difficult measurement method, electrolytic polishing precision, and long test time. Therefore, this study proposed the new method to improve the measurement precision of plastic zone depth and test time using TRIZ.

  • PDF

AE Characteristics of Fatigue Crack Opening and Closure in Structural Aluminum Alloy (구조용 알루미늄 합금에서의 피로균열 열림 및 닫힘 시 AE 발생특성 연구)

  • Jeong, Jung-Chae;Park, Phi-Lip;Kim, Ki-Bok;Lee, Seung-Seok;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.155-169
    • /
    • 2002
  • The objective of this study was to investigate the effect of crack opening and closure in the AE activities during fatigue test. Laboratory experiment using various materials and test conditions were carried out to identify AE characteristics of fatigue crack propagation. Compact tension specimens of 2024-T4 and 6061-T6 aluminum alloy were prepared for fatigue test. AE activities were analyzed based on the phase of the loading cycle. Generally, most of AE were generated when the crack begins' opening and the crack closes fully, whereas a few in the pull opening of the crack. Also AE activity in the peak loading of cycle was different with each specimen. However, in the same material, AE activity was not affected by the change of cyclic frequency (0.1, 0.2, 1.0Hz). It was found that AE activities during crack opening and closure depend on material properties such as micro-structure, tensile strength and yield strength.