• Title/Summary/Keyword: Fan Design

Search Result 894, Processing Time 0.031 seconds

Theoretical and experimental study for optimization method of particle removal fibrous filter used in ventilation system (입자 제거용 환기 필터의 설계 변수 선정 기법을 위한 이론 및 실험적 연구)

  • Jung, Yee-Kyeong;Noh, Kwang-Chul;Park, Jae-Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • Pressure drop and particle removal efficiency of two commercial fibrous medium filters were measured with 20~1,000 nm sized aerosolized KCl particles. Pressure drop and particle removal efficiency were also theoretically predicted and the results qualitatively agreed with the experimental data. For this given particle removal efficiency, a filter design method for obtaining minimum pressure drop (and therefore minimum fan power) was suggested in this study by selecting solidity and fiber diameter as parameters. Therefore, by carrying out theoretical and experimental approaches together, this paper introduced a way of finding conditions for low pressure drop and high performance of a fibrous filter, especially if the filter would be used in mechanical ventilation system.

  • PDF

Diffuser design for both auditorium and stage acoustics in concert halls (콘서트홀에서 객석과 무대의 음향방사를 위한 확산체 설계)

  • Kim, Jae-Ho;Kim, Yong-Hee;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.25-28
    • /
    • 2008
  • This study investigates the effect of geometrical shape of concert halls, with variation in the shape and location of diffusers. The acoustical characteristics both in the audience area and on the stage 1:50 scale models of shoebox and fan-shaped halls. It was found that the front side walls affect sound diffusion. The 1:50 scale model based on the Boston Symphony Hall was used for monaural impulse response measurements for calculation of RT, EDT, C80, G and ST1. In addition, calculating the numbers and amplitudes of reflection rays were applied to quantify diffusion phenomena.

  • PDF

An Intelligent Nano-positioning Control System Driven by an Ultrasonic Motor

  • Fan, Kuang-Chao;Lai, Zi-Fa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.40-45
    • /
    • 2008
  • This paper presents a linear positioning system and its control algorithm design with nano accuracy/resolution. The basic linear stage structure is driven by an ultrasonic motor and its displacement feedback is detected by a LDGI (Laser Diffraction Grating Interferometer), which can achieve nanometer resolution. Due to the friction driving property of the ultrasonic motor, the driving situation differs in various ranges along the travel. Experiments have been carried out in order to observe and realize the phenomena of the three main driving modes: AC mode (for mm motion), Gate mode (for ${\mu}m$ motion), and DC mode (for nm motion). A proposed FCMAC (Fuzzy Cerebella Model Articulation Controller) control algorithm is implemented for manipulating and predicting the velocity variation during the motion of each mode respectively. The PCbased integral positioning system is built up with a NI DAQ Device by a BCB (Borland $C^{++}$ Builder) program to accomplish the purpose of an intelligent nanopositioning control.

Optimal Flow Design of High-Efficiency, Cold-Flow, and Large-size Heat Pump Dryer (히트펌프를 이용한 고효율 냉풍 대형 건조기 유동 최적설계)

  • Park, Sang-Jun;Lee, Young-Lim
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2011
  • Drying process, corresponding to a final process in the area of food engineering, requires a lot of heat energy. Thus, the energy efficiency is very important for dryers. Since the energy efficiency of heat pump dryers is much higher compared to that of electric dryers or other types of dryers, most of large-capacity dryers are adopting heat pump. In this study, shapes, positions and number of air-circulating fans, guide vanes, air inlet, outlet and top separator were varied for optimization of the flow of a large-capacity heat pump dryer. In addition, fans were modelled with performance curves and porous media were assumed for foods and heat exchangers. The simulation results were applied to the 12-ton dryer and the velocity distributions were experimentally examined. Finally, uniform drying in time was successfully accomplished through frozen pepper experiment.

The Beauty of Line on Men′s Costume in the Chosun Period (조선시대 남자복식에 표현된 선(線)의 미(美))

  • 도주연;권영숙
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.4
    • /
    • pp.517-536
    • /
    • 2000
  • The purpose of this study is to investigate the internal and external line beauty of men's dress of the Chosun period from the views of dress design and dress aesthetics. 1) External Line Beauty of Men's Dress of the Chosun Period ① Functional Beauty : Having the beauty of functional line in terms of convenience, action, effectiveness, practivce and sanitation. ② Structural Beauty : Having the beauty harmonizing between lines of internal and external structures. ③ Ornamental Beauty : Having the beauty of simple line by matching accessories (gat, fan, sejodae, shoes) with a simple dress. ④ Wearing Beauty : Making tall-looking or expressing a mature masculine beauty by a visual mistake caused by a combination of internal and external structural beauty lines. 2) Internal Line Beauty of Men's Dress of the Chosun Period Including a simple but natural beauty based on natural philosophy, the beauty of courtesy emphasizing official hat and dress and the beauty of dress having aesthetic consciousness with which people enjoy an idyllic life.

  • PDF

A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant (R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구)

  • 정규하;박윤철;오상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

Design of micro lens array (Micro lens array 설계)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.204-211
    • /
    • 1994
  • Micro array lens systems are designed for a faximile or copy machine. The array type is hexagonal. Diameter of a lens is 0.16 mm and the distance of the center of the nearest neighbor is 0.192 mm. The magnitude of the lens system is 1:1. Working distane is 10.55 mm and the spot size is less than 0.04 mm radius on axis and 0.20 mm off-axis in case of single layer system. Working distance is 7.90 mm and the spot size is less than 0.07 mm radius on axis and 0.09 mm radius off axis in case of double layer system. Performance of single layer micro array lens system and double layer micro array lens system are compared with the characteristics of the ray fans.y fans.

  • PDF

Noise Reduction study in the Tractor Cab (트랙터 차실의 소음 저감에 관한 연구)

  • Chun, Du-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1461-1466
    • /
    • 2000
  • This paper investigates the noise reduction scheme in tractor cabin by using various steps of experiment. The experiments were performed in the field as well as in the lab to facilitate the detail test procedure. Some of the test results were compared with computational results. Several noise sources and paths were identified including the engine compartment (cooling fan and timing gear cover), hydraulic system and its components (hoses, tubes and there mount) and structural characteristics of the cab, window, mounting bracket and machine frame including steps. Throughout the several design changes, cab noise level was reduced from 80.2dBA to 74.8dBA.

  • PDF

OPTIMAL DESIGN OF PIEZOELECTRIC CANTILEVER FOR FAN BY THREE-DIMENSIONAL FINITE ELEMENT METHOD (3차원 유한 요소법을 이용한 팬용 압전 외팔보의 최적 설계)

  • Kim, Byoung-Jai;Rho, Jong-Suk;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.52-54
    • /
    • 2004
  • 압전 외팔보의 구조가 갈수록 복잡해짐에 따라 더 정확하고 효과적인 압전체의 해석이 요구되어지고 있다. 본 논문에서는 3차원 직육면체요소를 이용한 유한요소법을 통해 압전 변환기를 해석하고, 이것을 실험적으로 검증함으로써, 3차원 유한요소법을 이용한 해석 프로그램의 타당성을 확인하였다. 또한 3차원 유한요소법을 이용해서 압전 외팔보를 해석하고, 이것을 실험결과를 통해서 검증하였다. 그리고 압전 외팔보를 팬으로 적용하기 위해서 끝단에서의 최대 변위를 목적함수로 한 진화 전략 알고리즘을 적용하였다. 이를 통해서 팬용 압전 외팔보의 최적 설계를 수행하였다.

  • PDF

Design of performance testing device for heat exhaust ventilation fan (제연용 송풍기의 방염성능 시험장치 설계)

  • Lee, Young-Mo;Kim, Kwang-Yong;Lee, Jae-Yup;Jung, Hyun-Jong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.367-372
    • /
    • 2005
  • This study primarily is concerned with a new device which has been developed following the international standards to measure the ventilation performance at elevated temperature. This device can measure duration of ventilation, performance of electricity, static pressure at elevated temperature and also it is having provision to measure reversible performances during fire hazards. Invented device is closed circuit type system which is best suited for korean industrial environment with low cost and high efficiency. International standards has been compared and performance testing has been major using BS 7346 which is tested by Warrington Fire Research Centre.

  • PDF