• Title/Summary/Keyword: False Detection

Search Result 1,207, Processing Time 0.034 seconds

Convergence research on cytological diagnosis of gynecological diseases and genital HPV : Based on data from the Obstetrics and Gynecology Department of a general hospital located in Suwon-si (수원시 소재 일개 종합병원 산부인과에서 자궁경부 질환 검사의 실태조사 : HPV와 세포학적 검사의 융합연구)

  • Joung, You Hyun;Lee, Jun Min;Kim, Jong-Wan;Kim, Jae Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.1
    • /
    • pp.119-129
    • /
    • 2022
  • Cervical cytology has been widely used as a screening tool for cervical cancer. However, Human papillomavirus (HPV) detection and subtype testing are suggested to overcome the high false-negative rate associated with cytology. We aimed to investigate the clinical usefulness and infection rate in the HPV polymerase chain reaction (PCR) test performed in hospitals. HPV PCR data from 217 patients were analyzed. Analysis of variance revealed a significant difference in the infection rate among different age groups (P=0.015). The biopsy results showed that epithelial cell abnormalities and high HPV-positivity rate was observed in 1 (100%) subject aged <29 years, in 4 out of 5 (80%) patients in their 30s, and in 3 out of 4 (75%) patients aged ≥70 years. The prevalence of HPV infection was very high (46.1%). The highest prevalence (87.5%) was observed among patients in their <29, followed by those in their 30s (67.7%) and those in their 40s (31.9%).A high rate of epithelial cell abnormalities (≥ cervical intraepithelial neoplasia type 1, mild dysplasia) was observed in HPV-infected women aged<30 years. Therefore, extensive research and prevention activities are needed in this age group. HPV PCR testing is recommended to complement cervical cytology

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

Detection of Pyrazinamide Resistance in Mycobacterium Tuberculosis by Sequencing of pncA Gene (pncA 유전자의 염기 서열 결정에 의한 결핵균의 Pyrazinamide 내성 진단)

  • Hwang, Jee-Yoon;Kwak, Kyung-Rok;Park, Hye-Kyung;Lee, Ji-Seok;Park, Sam-Seok;Kim, Yun-Seong;Lee, Jung-Yoo;Chang, Chul-Hun;Lee, Min-Ki;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.94-105
    • /
    • 2001
  • Background : Examining the biological susceptibility of Mycobacterium tuberculosis to pyrazinamide (PZA) in vitro is very difficult as PZA is inactive under normal culture conditions. The biological susceptibility test, an enzyme assay for Pzase activity, and a genetic test for pncA gene mutations, were performed in order to predict PZA resistance. Methods : 28 cultured clinical isolates of Mycobacterium tuberculosis were tested. The biological susceptibility was performed by the absolute concentration method using Lowenstein-Jensen media. The PZase activity was tested by means of Wayne's method. A 710-bp region includes the entire open reading frame of pncA was amplified and sequenced. Results : All six strains with positive PZase activity exhibited no pncA mutations with one strain showing a false resistance in the biological susceptibility test. Among the 22 strains with no PZase activity, 21 exhibited showed pncA mutations. In the biological susceptibility test, 20 strains were resistant, and one was susceptible, and the other flied to test. The mutation types varied with ten missense, one silent and one nonsense mutation 1 slipped-strand mispairing, and 6 frameshift mutations. Three strains had an adenine to guanine mutation at position -11 upstream of the start codon. Conclusion : The mutation at the pncA promotor region is frequent at -11 upstream position. Automatic sequencing of pncA is a useful tool for rapid and accurate detection of PZA resistant M. tuberculosis, and for demonstrating the epidemiological relatedness of the PZA resistant M. tuberculosis strains.

  • PDF

Multi-resolution SAR Image-based Agricultural Reservoir Monitoring (농업용 저수지 모니터링을 위한 다해상도 SAR 영상의 활용)

  • Lee, Seulchan;Jeong, Jaehwan;Oh, Seungcheol;Jeong, Hagyu;Choi, Minha
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.497-510
    • /
    • 2022
  • Agricultural reservoirs are essential structures for water supplies during dry period in the Korean peninsula, where water resources are temporally unequally distributed. For efficient water management, systematic and effective monitoring of medium-small reservoirs is required. Synthetic Aperture Radar (SAR) provides a way for continuous monitoring of those, with its capability of all-weather observation. This study aims to evaluate the applicability of SAR in monitoring medium-small reservoirs using Sentinel-1 (10 m resolution) and Capella X-SAR (1 m resolution), at Chari (CR), Galjeon (GJ), Dwitgol (DG) reservoirs located in Ulsan, Korea. Water detected results applying Z fuzzy function-based threshold (Z-thresh) and Chan-vese (CV), an object detection-based segmentation algorithm, are quantitatively evaluated using UAV-detected water boundary (UWB). Accuracy metrics from Z-thresh were 0.87, 0.89, 0.77 (at CR, GJ, DG, respectively) using Sentinel-1 and 0.78, 0.72, 0.81 using Capella, and improvements were observed when CV was applied (Sentinel-1: 0.94, 0.89, 0.84, Capella: 0.92, 0.89, 0.93). Boundaries of the waterbody detected from Capella agreed relatively well with UWB; however, false- and un-detections occurred from speckle noises, due to its high resolution. When masked with optical sensor-based supplementary images, improvements up to 13% were observed. More effective water resource management is expected to be possible with continuous monitoring of available water quantity, when more accurate and precise SAR-based water detection technique is developed.

Development and Evaluation of Multiplex PCR for the Detection of Carbapenemase-Producing Enterobacteriaceae (카바페넴분해효소 생성 장내세균 검출을 위한 Multiplex PCR의 개발 및 평가)

  • Kim, Si Hyun;Bae, Il Kwon;Kim, Na Young;Song, Sae Am;Kim, Sunjoo;Jeong, Joseph;Shin, Jeong Hwan
    • Annals of Clinical Microbiology
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2019
  • Background: The isolation of carbapenemase-producing Enterobacteriaceae (CPE) has become increasingly common. Continuous surveillance for these organisms is essential because their infections are closely related to outbreaks of illness and are associated with high mortality rates. The aim of this study was to develop and evaluate multiplex PCR as a means of detecting several important CPE genes simultaneously. Methods: We aimed to develop a multiplex PCR that could detect seven CPE genes simultaneously. The multiplex PCR was composed of seven primer sets for the detection of KPC, IMP, VIM, NDM-1, GES, OXA-23, and OXA-48. We designed different PCR product sizes of at least 100 bp. We evaluated the performance of this new test using 69 CPE-positive clinical isolates. Also, we confirmed the specificity to rule out false-positive reactions by using 71 carbapenem-susceptible clinical strains. Results: A total of 69 CPE clinical isolates showed positive results and were correctly identified as KPC (N=14), IMP (N=13), OXA-23 (N=12), OXA-48 (N=11), VIM (N=9), GES (N=5), and NDM (N=5) by the multiplex PCR. All 71 carbapenem-susceptible clinical isolates, including Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, and Pseudomonas aeruginosa, showed negative results. Conclusion: This multiplex PCR can detect seven CPE genes at a time and will be useful in clinical laboratories.

Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite (COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증)

  • Moon, Yun Seob;Lee, Kangyeol
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.420-433
    • /
    • 2016
  • The purpose of this study is to improve the calibration matrixes of 2-D and 3-D convective rainfall rates (CRR) using the brightness temperature of the infrared $10.8{\mu}m$ channel (IR), the difference of brightness temperatures between infrared $10.8{\mu}m$ and vapor $6.7{\mu}m$ channels (IR-WV), and the normalized reflectance of the visible channel (VIS) from the COMS satellite and rainfall rate from the weather radar for the period of 75 rainy days from April 22, 2011 to October 22, 2011 in Korea. Especially, the rainfall rate data of the weather radar are used to validate the new 2-D and 3-DCRR calibration matrixes suitable for the Korean peninsula for the period of 24 rainy days in 2011. The 2D and 3D calibration matrixes provide the basic and maximum CRR values ($mm\;h^{-1}$) by multiplying the rain probability matrix, which is calculated by using the number of rainy and no-rainy pixels with associated 2-D (IR, IR-WV) and 3-D (IR, IR-WV, VIS) matrixes, by the mean and maximum rainfall rate matrixes, respectively, which is calculated by dividing the accumulated rainfall rate by the number of rainy pixels and by the product of the maximum rain rate for the calibration period by the number of rain occurrences. Finally, new 2-D and 3-D CRR calibration matrixes are obtained experimentally from the regression analysis of both basic and maximum rainfall rate matrixes. As a result, an area of rainfall rate more than 10 mm/h is magnified in the new ones as well as CRR is shown in lower class ranges in matrixes between IR brightness temperature and IR-WV brightness temperature difference than the existing ones. Accuracy and categorical statistics are computed for the data of CRR events occurred during the given period. The mean error (ME), mean absolute error (MAE), and root mean squire error (RMSE) in new 2-D and 3-D CRR calibrations led to smaller than in the existing ones, where false alarm ratio had decreased, probability of detection had increased a bit, and critical success index scores had improved. To take into account the strong rainfall rate in the weather events such as thunderstorms and typhoon, a moisture correction factor is corrected. This factor is defined as the product of the total precipitable waterby the relative humidity (PW RH), a mean value between surface and 500 hPa level, obtained from a numerical model or the COMS retrieval data. In this study, when the IR cloud top brightness temperature is lower than 210 K and the relative humidity is greater than 40%, the moisture correction factor is empirically scaled from 1.0 to 2.0 basing on PW RH values. Consequently, in applying to this factor in new 2D and 2D CRR calibrations, the ME, MAE, and RMSE are smaller than the new ones.

Microbial and Pathogenic Contamination of Ready-to-eat Fresh Vegetables in Korea (한국에 유통중인 신선편이 채소류의 미생물 품질 및 병원성 세균의 오염도 조사)

  • Bae, Young-Min;Hong, Yu-Jin;Kang, Dong-Hyun;Heu, Sung-Gi;Lee, Sun-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.161-168
    • /
    • 2011
  • The purpose of this study was to evaluate microbiological contamination of fresh vegetables in Korea. Twenty types of vegetables were tested for total aerobic bacteria, coliforms, Escherichia coli, yeast and mold, and pathogenic bacteria such as Staphylococcus aureus, Listeria monocytogenes, Bacillus cereus, Salmonella, E. coli O157:H7, Cronobacter sakazakii, Shigella, and Campylobacter. Levels of total aerobic bacteria and coliform on 20 vegetables were between 3.74 and 8.04 log CFU/g, and 0.16 and 5.02 log CFU/g, respectively. The highest contamination levels of total aerobic bacteria were observed on water dropwort, sprouts, mungbean sprout, and ballflower root. There was no significant difference (p>0.05) in microbial contamination levels of total aerobic count, coliform, E. coli, yeast and mold between organic and nonorganic vegetables. When isolation methods using selective agars were applied, L. monocytogenes, B. cereus, Salmonella and Campylobacter were isolated from some fresh vegetable samples. Results of API kit tests showed that L. monocytogenes was identified on Chinese cabbage, cucumber, soybean sprouts, and iceberg lettuce while Salmonella was identified on Korean leek. Furthermore, Campylobacter jejuni was also identified in more than 50 of the 100 samples. However, when positive samples from API kit were tested for real-time PCR or 16S rRNA sequencing method, only B. cereus from perilla leaf, carrot, water dropwort, and sprouts showed positive results. These results indicate that selective agar and API kit detection methods might result in false positive results for some pathogens. Therefore, studies need to improve isolation or confirmation methods for such pathogens.

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

A study of Diagnostic Significance of Simultaneous Examination of Proteinuria and Hematuria in the Urinary Mass Screening (집단뇨검사(Urinary mass screening) 방법으로 단백뇨와 혈뇨의 동시검사가 가지는 진단적 가치에 대한 연구)

  • Kim, Young-Kyoun;Lee, Chong-Guk
    • Childhood Kidney Diseases
    • /
    • v.3 no.1
    • /
    • pp.57-63
    • /
    • 1999
  • Purpose : To evaluate the diagnostic significance of simultaneous examination of hematuria and proteinuria in the urinary mass screening for early detection ot incipient renal diseases. Method and Object : During the period of 4 months from August to December in 1997, we did urinary mass screening on students of first grade of high school (16 years aged group) nationwide together with Korean Association of Health(KAH). In the first screening test, Comber-10 $N^{(R)}$ M dipsticks were used to detect proteinuria, hematuria, pyuria and nitrite simultaneously. Total 26,508 students (16 years aged group) from 33 high schools in every province in Korea, respectively, complied to the urinary mass screening. After then, one high school in Seoul was selected to reveal the true incidence of incipient renal diseases among students who showed hematuria in the initial screening through intensive examinations. Those who had hematuria and/or proteinuria visited the Paik hospital, and underwent blood tests and ultrasonographic examinations. The results were evaluated. Results 1) The initial screening revealed that the prevalence of proteinuria, hematuria, pyuria and positive nitrite urine, were $0.73\%,\;2.69\%,\;0.23\%\;and\;0.03\%$, respectively. 2) The first urinary screening among 875 students from one high school in Seoul selected fir the second test showed proteinuria, hematuria, pyuria and positive nitrite urine, were $0.91\%,\;4.68\%,\;0.34\%\;and\;0\%$, respectively. a) Total 8 among 875 students showed proteinuria, but one of them had orthostatic proteinuria and those remaining 7 students had transient proteinuria. b) There were 41 students who had hematuria in the initial screening. Among 33 who complied the second test, only one student showed asymptomatic isolated hematuria and those remaining students were normal. Conclusion : 1) Because of high false positive hematuria rate in the urinary mass screening, it dosen't seem to be appropriate that hematuria screening using dipsticks be included in the urinary mass screening. 2) A unified organization is needed from the fret that so various results of urinary mass screening came out. 3) Positive rates of pyuria and nitrite were so low that validity of urinary mass screening for urinary tract infection needs more studies.

  • PDF

Staging of Esophageal Cancer Using Positron Emission Tomography : Comparing to Computed Tomography (양전자방출단층촬영술(PET)을 이용한 식도암 환자의 병기 결정 -전산화단층촬영술(CT)과의 비교-)

  • 심영목;박승준;김병태;김성철
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.388-393
    • /
    • 1999
  • Background: Correct preoperative staging of esophageal cancer is a prerequisite for adequate treatment. We prospectively compared the accuracy of positron emission tomography (PET) with [fluorine-18]FDG in the staging of esophageal cancer to that of computed tomography (CT). Material and Method: The findings of FDG PET and of chest CT including lower neck and the upper abdomen of 20 biopsy-proven squamous cell carcinoma patients (male, 19; female, 1; mean age, 61) were compared with the pathologic findings obtained from a curative esophagectomy with lymph node dissection. Result: The sensitivities of FDG PET and CT for diagnosis of primary tumor were the same, 90.0% (18/20). Both FDG PET and CT failed to show the primary tumor in 2 of 20 patients; one had a 1cm sized carcinoma in situ and the other had T1 stage cancer. By using the results of the pathologic examinations of 193 removed lymph node groups, we calculated the diagnostic sensitivities, specificities and accuracies of PET and CT (*$\chi$2 p < 0.005). Sensitivity** Specificity Accuracy* PET 55.6%(30/54) 97.1%(135/139) 85.5%(165/193) CT 13.0%(7/54) 98.6%(137/139) 74.6%(144/193) One of four patients with a false-positive for PEThad had active pulmonary tuberculosis. Among the 24 tumor involved lymph node groups, PET failed to show tumor metastasis in 5 lymph node groups abutting the tumor and in 14 lymph node groups located where the decay correction was not performed. Conclusion: Based on the above findings, it is suggested that [F-18]FDG-PET is superior to CT in the detection of nodal metastases and in the staging of patients with esophageal cancer.

  • PDF