• Title/Summary/Keyword: Fall-of-potential method

Search Result 77, Processing Time 0.026 seconds

Enhanced 3D Residual Network for Human Fall Detection in Video Surveillance

  • Li, Suyuan;Song, Xin;Cao, Jing;Xu, Siyang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.12
    • /
    • pp.3991-4007
    • /
    • 2022
  • In the public healthcare, a computational system that can automatically and efficiently detect and classify falls from a video sequence has significant potential. With the advancement of deep learning, which can extract temporal and spatial information, has become more widespread. However, traditional 3D CNNs that usually adopt shallow networks cannot obtain higher recognition accuracy than deeper networks. Additionally, some experiences of neural network show that the problem of gradient explosions occurs with increasing the network layers. As a result, an enhanced three-dimensional ResNet-based method for fall detection (3D-ERes-FD) is proposed to directly extract spatio-temporal features to address these issues. In our method, a 50-layer 3D residual network is used to deepen the network for improving fall recognition accuracy. Furthermore, enhanced residual units with four convolutional layers are developed to efficiently reduce the number of parameters and increase the depth of the network. According to the experimental results, the proposed method outperformed several state-of-the-art methods.

Telemonitoring System of Fall Detection for the Elderly (노인을 위한 원격 낙상 검출 시스템)

  • Lee, Yong-Gyu;Cheon, Dae-Jin;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.420-427
    • /
    • 2011
  • The population of elderly people increases rapidly as our society moves towards the aged one. Healthcare for the elderly becomes an important issue and falling down is one of the critical problems although not well recognized. In this study, a fall detection system was developed using a 3-axis accelerometer. Analyzing fall patterns, we took into account the degree of impact, posture angle, the repetitions of similar movements and the activities after a potential fall and proposed an algorithm of fall detection. Information of the fall sensor was sent to a remote healthcare server through the wireless networks of Zigbee and WLAN. Our system was designed to monitor multiples users. 12 persons participated in experiment and each one performed 24 different movements. Our proposed algorithm was compared with other reported ones. Our method produced the excellent results having a sensitivity of 96.4 % and a specificity of 100 % whereas other methods had a sensitivity range between 87.5 % and 94.8 % and a specificity range between 63.5 % and 83.3 %.

Analysis of the Frequency Dependent Characteristics of Ground Impedance of a Ground Rod (봉상접지전극의 접지임피던스의 주파수의존성의 분석)

  • 이복희;엄주홍
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.426-432
    • /
    • 2004
  • This paper presents a systematic approach of measurement, modeling and analysis of grounding system impedance in the field of lightning protection system and intelligent power equipments. The measurement and analysis system of ground impedance is based on a computer aided technique. The magnitude and phase of ground impedance were determined by the novel measurement and analysis using the revised fall-of-potential method. The ground impedances of the ground rod of 50 m long are considerably dependent on the frequency. The ground impedance is mainly resistive in the frequency range of 3-20 kHz. At higher frequencies, the reactive components of the ground impedances are no longer negligible and the inductance of the ground rod was found to be the core factor deciding the ground impedance. Although the steady-state ground resistance of the ground rod of 50 m was less than that of the ground rod of 10 m, the ground impedances of the ground rod of 50 m over the frequency range of more than 60 kHz were much greater than those of the ground rod of 10 m. Furthermore, the equivalent circuit model based on the measured data was proposed. and the calculated results were in approximately agreement with the measured data.

Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid (접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

Suggestion of New Method for the Prediction of Shock Vibration (충격진동 예측방법에 관한 새로운 방법 제안)

  • Cho, Kyu-Yong;Kang, Choo-Won;Go, Jin-Seok
    • Explosives and Blasting
    • /
    • v.26 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • In case of estimating the shocking vibration during the blasting demolitions, the weight and falling height of the structure, that is a potential energy, had been considered. But, this study presented a new equation which used the impulse concerning a falling weight instead of potential energy as a method of predicting the shock vibration. In this experiment, the data of the impulse were compared with the data of the potential energy by performing the free-fall, and all data were comparatively analyzed by the regression analysis method. Also, the method of the superposition theory, which is calculated by the diminution ratio according to distance, the free-fall difference according to height, and the time giving the shock to the ground according to the breakdown pattern, was compared with the previous vibration data occurring from the blasting demolitions in the same conditions. As a result, this study suggests that the impulse and the method of superposition theory be applied as a method of predicting the shocking vibration. Therefore, these results could be expected to estimate the shocking vibration more accurately than the previous method.

Evaluation of Errors Due to Earth Mutual Resistance in Measuring Ground Impedance of Vertically-driven Ground Electrode (수직 접지전극의 접지임피던스 측정에서 도전유도에 의한 오차 평가)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1778-1783
    • /
    • 2009
  • Ground impedance for the large grounding system is measured according to the IEEE Standard 81.2 which is based on the revised fall-of-potential method of installing auxiliary electrode at a right angle. When the auxiliary electrodes are located at an angle of $90^{\circ}$, the ground impedance inevitably includes the error due to earth mutual resistance. In this paper, in order to accurately measure the ground impedance of vertically-driven ground electrodes, error rates due to earth mutual resistance are evaluated by ground resistance and ground impedance measuring devices and compared with calculated values. As a result, the measured results are in good agreement with the computed results considering soil layer with different resistivity. The error rates due to earth mutual resistance decrease with increasing the length of ground electrode in the case that the ratio of the distance between the ground rod to be measured and the auxiliary electrodes to the length of ground electrode(D/L) is same. The ground impedance should be measured at the minimum distance between the auxiliary electrodes that will have an estimated measurement accuracy due to earth mutual resistance.

Measurement and Analysis for Grounding Resistance of A Large Scale Hydroelectric Power Plant (대규모 수력발전설비 접지저항 측정 및 분석)

  • Lee, Eun-Chun;Hong, Sung-Taek;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.79-81
    • /
    • 2000
  • Measurement used electrical sounding(MacOHM 2115, Japan) for large scale grounding resistance of So-Yang Dam hydroelectric power plant. To applied measurement method is fall of potential method. This result propose to method of efficient administration for grounding system.

  • PDF

A Proposal for Construction Plan of Electric Corrosion from Measurement and Analysis for Earth Resistivity of Ha-Nam IC Water Pipe Line (하남IC 상수도관로 대지비저항 측정 및 분석에 따른 전기방식 시공방안 제시)

  • Shin, Gang-Wook;Lee, Eun-Chun;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.355-357
    • /
    • 2000
  • Measurement used electricsal sounding(MacOHM 2115, Japan) for grounding resistance of Jung-Bu highway Ha-Nam IC about 500m. To applied measurement method is fall of potential method and analysis earth resistivity used ESII(Electrical Sounding Interactive Interpretation) program. This result propose for construction plan of electric corrosion.

  • PDF

Reduction of the the Ground Surface Potential Gradients by Installing Auxiliary Grounding Grids (보조접지그리드의 시설에 의한 대지표면전위경도의 저감)

  • 이승칠;엄주홍;이복희;김효진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.121-129
    • /
    • 2002
  • The present paper describes a technique for installing an effective grounding grids, the major objective is forced on the experimental evaluation of the performance and characteristics with the arrangement and installation method for grounding grids consisting of the means to protect electric shock, electronics and computerized facilities against lightning, switching and ground fault surges. The study is oriented on two major areas: (1) the analysis of the ground surface potential gradient with the arrangement of grounding grids, (2) the control of the dangerous ground surface potential rise. The experiments wee carried out with the impulse currents as a function of the installation method or arrangement of grounding grids. An installation method of the inclined auxiliary grounding grid was proposed to overcome the drawbacks of equally spared grounding grids, i.e. an appropriate design concept far the installation of grounding grids was found out, It has been shown that the installation of the intwined auxiliary grounding grid can also result in a mere than 50% decrease in the maximum potential gradient on the ground surface and enhance the level of safety for persons and electronic equipments..

Home Environmental Hazards of Falling Accident in the Elderly (노인가정의 낙상사고 위험 환경요인)

  • Park, Young-Hae;Moon, Jung-Soon
    • Korean Journal of Health Education and Promotion
    • /
    • v.22 no.4
    • /
    • pp.203-213
    • /
    • 2005
  • Purpose: To assess the environmental hazards of falling accident in the homes of the elderly. Method: 222 homes of the elderly were assessed by the home environmental Checklist from May to July in 2003. Results: The mean score of home environmental hazards for fall were 13.19 with the highest score being 49, ranging from 4 to 24. The bathroom was the most hazardous place in the home, porch came next bedroom, kitchen, living room and stair followed them. The floor surface such as finishes and non-skid mats was the most hazardous interior factor in the home, using bathroom came next furniture and illumination followed them. The floor surface such as finishes and non-skid mats in the bathroom, kitchen, living room and porch, illumination of bedroom and stair were the most prevalent hazards in the home of interior. Of the 49 potential hazards, bathroom grab bar was the most prevalent one with 89.9%, and non-skid rugs in the porch, bathroom and kitchen, safety of dinner table, the threshold and furniture of porch, and illumination of bedroom were prevalent more than half of the home under assessing. Men, living in the separate house or villa with stairs were in more hazardous environments. Conclusion: To reduce the potential hazards of fall accident in the home, improving hazards relating to floor surface such as slip resistance surface and mats is important specially those of the separate house or villa with stairs.