• Title/Summary/Keyword: Facility communication

Search Result 574, Processing Time 0.028 seconds

Improving Drug Quantity Accuracy using Displacement Sensor in Pharmacy Automation Management System (약국 자동화 관리 시스템에서 변위 센서를 이용한 약품 수량 정확도 개선)

  • Park, Kiyoung;Kim, Hoyoung;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.9
    • /
    • pp.1032-1037
    • /
    • 2019
  • In the existing pharmacy automation system, quantity control was carried out only in the memory without first measuring the quantity of the medicine and during the operation of the facility. As a result, the number of drugs that have already been deducted during operation at the time of a facility error has not been managed. Serious problems are caused by important medicines that need to be managed because of lack of quantity control. In addition, the user had to refill the drug when it was exhausted because the user could not know the amount of the drug outside the facility. When the drug was out of stock, the facility was operating with loss of time to restart and the time to replenish the drug. Thus, in this paper, we designed and applied system to control the quantity of medicines frequently by adding displacement sensors to the robot of the facility.

Implementation of Facility Management System for Plant Factory (식물공장 시설관리 시스템의 구현)

  • Lee, Yong-Woong;Seo, Beom-Seok;Kim, Chan-Woo;Kim, Kyung-Hee;Park, Yang-Ho;Shin, Chang-Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.141-151
    • /
    • 2011
  • This paper suggests the Facility Management System for plant factory promising to be a core technology of the agriculture in the future. This system makes diagnoses that status from sensors or facilities in the factory for exact operation and monitors the internal environment with the control status in real-time. It is expected that we could operate a plant factory safely and effectively by using the system. The system consists of the data management module, the context provider module, the context interpreter module, the service provider module, the data storage and user interface. The system provide with the failure diagnosis service, the facility control service, and the high-reliability monitoring service via the interactions between above modules. The failure diagnosis service determines whether the sensors or facility devices are in failure or not, and informs the administrator of their conditions. The facility control service is activated in case if the facilities need to be managed during the diagnosis for failure or malfunction processes. The high-reliability monitoring service provides the administrator with verified data through the failure diagnosis service. Then we confirmed that the suggested system operates correctly through the system simulation.

A Study on the Procedure for Establishing an Integrated Platform Plan for Safety Management of 5G Digital Twin-Based Facilities: Focusing on Facilities in Metropolitan Cities (5G 디지털 트윈 기반 시설물 안전관리 통합플랫폼 계획 수립 절차에 관한 연구 : 수도권 광역시 시설물을 중심으로)

  • Chang, Hye-Jung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.4
    • /
    • pp.257-268
    • /
    • 2021
  • As the variety and scale of facilities increase due to industrialization and urbanization, blind spots for facility safety management have occurred, resulting in numerous casualties.To meet safety and security needs of citizens living in smart cities, we present a procedure for establishing an integrated platform for facility safety management by combining 5G and digital twin technologies. It can be used to perform inspection according to risk factors and aging of facilities. In this paper, the current status of facility management and application directions of new 5G digital twin-based smart city technologies are reviewed and digital twin implementation procedures are presented. Five cities were selected as target areas: Osan, Gwangmyeong, Guri, Uijeongbu, and Anyang. Old and emergency facilities of each local government were selected. A total of 33 digital twin facilities reflecting policy directions of each city were selected. Focusing on facilities determined by each city, the purpose of this study was to define information technology infrastructure elements for the application of the 5G digital twin facility safety management integrated platform, define categories of implementation services, and suggest a concrete integrated platform configuration plan.

The Communication Method at the Auto-Startup System using TCP/IP and VXI and Expert System(G2)

  • Kim, Jung-Soo;Joon Lyon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.1 no.2
    • /
    • pp.141-146
    • /
    • 1999
  • This paper describes the communication method of an auto-startup system. The Auto-Startup system is designed to operate a nuclear power plant automatically during the startup operation . In general , the operations during startup in existing plant have only been manually controlled by the operator. The manual operation caused to the operator mistake. The Auto-Startup system consists of the Distributed Control System(DCS) and G2 (Expert System). Also, Functional Test Facility(FTF) provides the plant's real-data for an Auto-Startup system. So, it is necessary to develop the communication method between these systems. We developed two methods ; one is a network and the other is a hardwire line. To communicate between these systems (DCS-G2 and DCS-FTF) , we developed the communication program. In case of DCS-FTF, we used the TCP/IP and VXI. BUt, in case of DCS-G2 , we , what it called , developed the bridge program using the GSI(G2 Standard Interface). We test to check the function of the important parameter, in time, for analysis of the developed communication method. The results are a good performance when we check the communication time of important parameter. We conclude that Auto-startup system could save heat-up time about at least 5 hours and reduced the change of the reactor operation and trip.

  • PDF

Development of Displacement Measuring Sensor Module to Monitoring About Variation and Distortion for Bridge Infrastructure at Wireless Communication Environmental (교량구조물의 구조적 변형을 측정하는 무선통신기반 변위센서모듈 개발)

  • Ryu, Seung-Ki;Moon, Hak-Yong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.87-95
    • /
    • 2010
  • Lots of bridge structure generated the change of outward formation according to durability capability and decrepitude by long use. Especially, in case of the typhoon, snowing and earthquake is going to make rapidly more worse formation about the old structural facilitys. Also, outward formation by irregular and micro-distortion in bridge structure could not easily checked by normal diagnostics method. As a result, performance-capability of structure facility is getting to make a decline in standard of structure performance. Recently, real-time monitoring technology by wireless environment go into the study of irregular movement for structure facility. This paper presents the development of sensor to displacement checking about bridge structure. Sensing method of developed sensor put bring into the gyroscope technology using the acceleration speed and angular acceleration speed. This paper also will simulated to verified the monitoring capability of developed sensor against random vibration, frequency and distortion in simulated equipment.

The Development of Effective Database Model for Pipe Network Management Monitoring Program (상수도 관망시스템의 유지관리용 모니터링 프로그램을 위한 효율적 D/B 모델의 개발)

  • Kang, Byung-Mo;Lee, Hyun-Dong;Hong, In-Sik
    • Journal of Internet Computing and Services
    • /
    • v.9 no.4
    • /
    • pp.157-166
    • /
    • 2008
  • There has been a renewal of interest in management of underground facility in recent years. As several research have been made on management for underground facility of waterworks pipe. In this paper smart-tag is defined and applied to requiring ubiquitous environment. Also, GPS is essential technology for the implementation of proposed program, which has GPS and RFID mixed business model. And it manages data of underground facility with RFID system effectively and provides the high quality practical effectiveness of entire system through GPS receiving module and network communication on GIS. In conclusion, this paper proposed applications management system with location mixed database. Proposed database and interface skill is tested and evaluated through the simulation.

  • PDF

A study on the MVNO Wholesale Price in Competitive Communication Service Market (경쟁적인 통신서비스 시장에서 MVNO 도매대가 산정에 관한 연구)

  • Sawng, Yeong-Wha;Bae, Khee-Su;Jeon, Heung-Joo
    • Journal of Information Technology Applications and Management
    • /
    • v.19 no.2
    • /
    • pp.217-231
    • /
    • 2012
  • In the past, companies should make enormous facility investment and acquire a right to do business in order to join communication markets, but now they can do business without important facilities, such as communication networks. Such a movement to ease regulations about companies which want to newly join the communication industry is expected not only to change a competition frame of the mobile communication market but also to greatly affect the entire communication industry. Through this study aiming to look into a way to calculate a reasonable wholesale price related to the government's introduction of the Mobile Virtual Network Operator (MVNO) system, I came up with a following result. I applied the operating profit percentage and the ratio of operating gain to cost to the cost plus model and retail minus model, respectively, to calculate the wholesale price and found that when I calculated with the cost plus model applying the operating profit percentage, I could get the highest wholesale price. On the other hand, I got the lowest wholesale price with the retail minus model by applying the operating profit percentage. Division of expenses and calculation of profit percentage are important factors in calculating the wholesale price and such results are expected to help accurate calculation of the MVNO wholesale price.

CReMeS: A CORBA COmpliant Reflective Memory based Real-time Communication Service

  • Chung, Sun-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.10B
    • /
    • pp.1675-1689
    • /
    • 2000
  • We present CReMeS a CORBA-compliant design and implementation of a new real-time communication service. It provides for efficient predictable and scalable communication between information producers and consumers. The CReMeS architecture is based on MidART's Real-Time Channel-based Reflective Memory (RT-CRM) abstraction. This architecture supports the separation of QoS specification between producer and consumer of data and employs a user-level scheduling scheme for communicating real-time tasks. These help us achieve end-to-end predictability and allows our service to scale. The CReMeS architecture provides a CORBA interface to applications and demands no changes to the ORB layer and the language mapping layer. Thus it can run on non real-time Off-The-Shelf ORBs enables applications on these ORBs to have scalable and end-to-end predictable asynchronous communication facility. In addition an application designer can select whether to use an out-of-band channel or the ORB GIOP/IIOP for data communication. This permits a trade-off between performance predictability and reliability. Experimental results demonstrate that our architecture can achieve better performance and predictability than a real-time implementation of the CORBA Even Service when the out-of-band channel is employed for data communication it delivers better predictability with comparable performance when the ORB GIOP/IIOP is used.

  • PDF

Influence and analysis of a commercial ZigBee module induced by gamma rays

  • Shin, Dongseong;Kim, Chang-Hwoi;Park, Pangun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1483-1490
    • /
    • 2021
  • Many studies are undertaken into nuclear power plants (NPPs) in preparation for accidents exceeding design standards. In this paper, we analyze the applicability of various wireless communication technologies as accident countermeasures in different NPP environments. In particular, a commercial wireless communication module (WCM) is investigated by measuring leakage current and packet error rate (PER), which vary depending on the intensity of incident radiation on the module, by testing at a Co-60 gamma-ray irradiation facility. The experimental results show that the WCMs continued to operate after total doses of 940 and 1097 Gy, with PERs of 3.6% and 0.8%, when exposed to irradiation dose rates of 185 and 486 Gy/h, respectively. In short, the lower irradiation dose rate decreased the performance of WCMs more than the higher dose rate. In experiments comparing the two communication protocols of request/response and one-way, the WCMs survived up to 997 and 1177 Gy, with PERs of 2% and 0%, respectively. Since the request/response protocol uses both the transmitter and the receiver, while the one-way protocol uses only the transmitter, then the electronic system on the side of the receiver is more vulnerable to radiation effects. From our experiments, the tested module is expected to be used for design-based accidents (DBAs) of "Category A" type, and has confirmed the possibility of using wireless communication systems in NPPs.

Radio Frequency Based Emergency Exit Node Technology

  • Choi, Youngwoo;Kim, Dong Kyoo;Kang, Do Wook;Choi, Wan Sik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.91-100
    • /
    • 2013
  • This paper introduces an indoor sensor fusion wireless communication device which provides the Location Based Service (LBS) using fire prevention facility. The proposed system can provide information in real time by optimizing the hardware of Wi-Fi technology. The proposed system can be applied to a fire prevention facility (i.e., emergency exit) and provide information such as escape way, emergency exit location, and accident alarm to smart phone users, dedicated terminal holders, or other related organizations including guardians, which makes them respond instantly with lifesaving, emergency mobilization, etc. Also, the proposed system can be used as a composite fire detection sensor node with additional fire and motion detect sensors.