• Title/Summary/Keyword: Facility Maintenance

Search Result 881, Processing Time 0.028 seconds

Development of Facility Management System for Indoor Space Based on ICBM Technology (ICBM기반 실내 공간 유지관리 시스템 개발)

  • Jung, Yoo-Seok;Kang, Tae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.49-55
    • /
    • 2019
  • An open office or a shared office is emerging as the emphasis on the collaborative and communicative work environments is increasing. In the past, the user maintained the space, but the maintenance of indoor space became difficult because there is no fixed user. Indoor space information can be collected using the ICBM framework system. The facility management can achieve this with data. Therefore, this study proposed a framework based on ICBM (Internet of Things, Cloud, Big Data, and Mobile) for verifying the possibility of a smart facility management system for indoor space. IoT (Internet of Things) technology was used to measure the indoor temperature, humidity, occupancy, and brightness continuously, and provided the data to Web API via WiFi. Data acquired automatically via IoT, existing maintenance data, and spatial information were integrated through the Cloud. Big data collected by sensors were processed as meaningful spatial information for maintenance. Indoor space information and maintenance information can be delivered to the manager through the mobile. Based on the collected data, room occupancy recognition is limited due to a range of ultrasonic wave sensors. On the other hand, brightness represents the space conditions. The difference between lighting on/off, weekday and weekend can be shown. The temperature data and the relative humidity data were collected steadily to evaluate the comfort.

An Integrated AHP-VIKOR Methodology for Facility Layout Design

  • Shokri, Hamidreza;Ashjari, Behzad;Saberi, Morteza;Yoon, Jin Hee
    • Industrial Engineering and Management Systems
    • /
    • v.12 no.4
    • /
    • pp.389-405
    • /
    • 2013
  • A facility layout design (FLD) problem can be generally introduced as assignment of facilities (departments) to a site such that a set of criteria are satisfied or some objectives are minimized (maximized). Hence, it can be considered as a multi-criteria problem due to the presence of qualitative criteria such as maintenance or flexibility and quantitative criteria such as the total cost of handling material. The VIKOR method was developed to solve multiple criteria decision making problems with conflicting and non-commensurable (different units) criteria, assuming that compromising is acceptable for conflict resolution, the decision maker wants a solution that is the closest to the ideal, and the alternatives are evaluated according to all established criteria. This paper proposes a hierarchical analytic hierarchy process (AHP) and VIKOR approach to solve the FLD problem. A computer-aided layout-planning tool is adopted to generate the facility layout problems, as well as their quantitative data. The qualitative performance measures are weighted by AHP. VIKOR is then used to solve the FLD problem. Finally, the proposed integrated procedure is applied to three real-time examples.

The politic suggestion and the design of integrate-construction model for installation of the residential IT facility. (구내 정보통신설비를 위한 정책제안과 통합구축모델 설계)

  • Kang, Young-Chang;Lim, Sang-Chul;Kim, Sun-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.5
    • /
    • pp.845-853
    • /
    • 2009
  • This study recognize the problems about the High-speed IT building certification system and the technical standards of telecommunication facility, broadcasting public receiving facility including Home-network facility which are installed at apartments for the successful building of the Ubiquitous city that the government is driving and suggested a sweeping change of the housing law interrelated for making up a housing efficiency grade-display system and systematizing the maintenance by solutions. Also, presented the integrate-construction model designs separately of the residential IT line about the buildings applied to technical standards, the building acquired second grade below of High-speed IT building and the building when the above solutions get to he systematized.

A Study on the Facility Eligibility Inspection of National Inpatient Isolation Units (국가지정 입원치료 격리병상 시설적격성 평가분석에 관한 연구)

  • Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.506-514
    • /
    • 2015
  • During the progression of this study, we visited 17 medical institutions. These medical institutions underwent inspection for facility eligibility of national inpatient isolation units to care for patients. Seventeen consultation meetings were held to gather expert opinions, and conferences were held with the medical institutions and local levels of government. Based on these facts, we established a field application model of the criteria of safety-management and conducted a study on this method in order to create more scientific and systematic safety-management criteria including criteria regarding facilities maintenance and methods of equipment inspection. According to an analysis on the 17 medical institutions examined, facility eligibility of 17 national inpatient isolation units was found to be 78.3% on average. Through analysis of the present domestic and foreign conditions of medical institutions, we proposed improvements for when remodeling becomes necessary and established criteria for safety-management in national inpatient isolation units for the care of patients in accordance with the domestic healthcare system.

Design and Implementation of a GPS-based Drainage Management System (GPS 기반 배수설비 관리 시스템 설계 및 구현)

  • Kim, Ji-Seong;Jang, Si-Woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.126-129
    • /
    • 2021
  • The existing drainage facility management system is not systematically computerized, and it is difficult to manage each drainage facility on-site due to insufficient information and location management. Currently, in the current drainage system management, repair technicians recognize the information of the drainage facility by recognizing the QR code at the site. These methods have difficulty locating QR codes in the field, and the problem is that they incur additional maintenance costs due to loss and breakage of QR code attachments. The GPS-based drainage management system proposed in this paper stores and manages each drainage facility's data including GPS information, allowing applications to use the location and information of drainage facilities based on user location data.

  • PDF

Investigation on Replacement Criteria for Aged Diesel Driven Power Generation Facility by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 노후 디젤발전설비 교체기준 고찰)

  • Park, Myungsoo;Song, Gee Wook;Seo, Sang Il;Won, Dong Ju
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • The diesel driven power generation facility provides most of electricity of island region where is isolated from the main land power supply system. It is possible to extend the life of diesel driven power generation facility by periodic maintenance. However, the long-term use of diesel driven power generation facility increases the operating cost due to aging hardware and reduced plant efficiency. In other words, on-time replacement of aging diesel driven power generation facility reduces plant operation cost. The purpose of this study presents major indicators to represent the characteristics of the diesel generator and conducts sensitivity analysis using Monte Carlo analysis. In addition, status core which indicates quantitatively the state of the diesel driven power generation facility is defined and prepare the replacement criteria based on the state score.

A Study on Improvement Method by Environmental-Friendly Planning Elements of High-rise Residential Complex (초고층 복합주거단지의 친환경 계획요소 평가를 통한 개선방안에 관한 연구)

  • Hwang, Jung-Man;Lee, Joo-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1522-1530
    • /
    • 2014
  • High-rise residential complex type is getting important as new town development and urban regeneration in the downtown area. However, literature review of high-rise residential complex and research on satisfaction analysis of real residents are lack. Therefore, this paper is analyzing environmental friendly planning elements of high-rise building as housing subdivision, inside of building, facility, and maintenance by a survey on experts. The purpose of this paper is to suggest improvement method of environmental-friendly planning elements of high-rise residential complex by M-IPA. First, as a result, the part of housing subdivision has to keep complex land utilization, environmental-friendly transportation. Second, the part of inside of building shows that ecological housing subdivision, indoor air environment urgent and indoor temperature environment keeps maintaining. Finally, the part of facility/maintenance shows that material and facility, and index of energy management are urgently needed.

Analysis of Position Accuracy for Underground Facility Using RTK-GPS (RTK-GPS를 이용한 지하시설물의 위치 정확도 분석)

  • 박운용;이종출;정성모
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.237-243
    • /
    • 2003
  • The complicated facilities on the ground have begun to be laid under the ground as increasing emphasis on the beauty of cities due to centralization. But, as the kind of the facilities have been concentrated on the narrow area, accidents occur due to the difficulty of maintenance and the inaccuracy of location information. In this study, first we constructed the field test model to compare with the method of underground probing. So, we could know that the electromagnetic induction method and GPR(Ground Penetration Radar) are useful. It was acquired the position information for the underground facilities using a RTK-GPS. As the result, we have analyzed the accurate position of the underground facility and show the way improving accuracy in detecting and surveying comparing with the traditional surveying method. Also, we hope to contribute the effective maintenance and prevention of disasters to the underground facility as using underground facilities 3D position with Arcview and building the DB of exact depth and underground facilities information system.

Estimation of National Loss Expenses to Insufficient Safety Inspection and Precision Safety Diagnosis (부실 정밀점검 및 정밀안전진단의 국가적 손실비용 추정)

  • Ha, Myung-Ho;Park, Jong-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.246-253
    • /
    • 2010
  • National major facilities have been rigorously investigated using regular safety inspections and precision safety diagnosis since the Special Law for Facilities Safety Management was made in 1995. However, the process of safety inspection and precision safety diagnosis could be doubted due to intervention of facility owner for safety level evaluation, competition to obtain low price order, and low technical skills of inspection companies. Although the management processes for evaluating the inspection companies were used for several years, the process should continue to improve in the safety inspection field. This study analyzed the recent evaluation system and the ratios of insufficient inspection. Estimation of national loss expenses to the insufficient safety inspection was investigated to recognize the necessity for the improvement of facility inspection process and evaluation system.

Performance Evaluation for Deteriorated Masonry in Military Facilities (조적조 노후 군시설의 성능 평가)

  • Yang Eun-Bum;Shin kyoung-Hee;Hwang Jong-Hyun;Kim In-Ho;Kim Yong-In;Park Tae-keun;Lee Chan Shik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.434-438
    • /
    • 2001
  • Military facilities with masonry construction have a great portion in the whole military facilities. But lots of them have been used for more than 20 years, the degree of deterioration of the facilities are very serious. Futhermore, as small budget for the facilities maintenance and poor maintenance, the performance of the aged masonry facilities have continually decreased. We suggest a structural performance assesment criteria for the military facility through literature review, interview with experts and questionnaire. The assesment of structural performance includes the inclining and sinking degree of the facilities, durability of materials and resisting force of the structural members.

  • PDF