• Title/Summary/Keyword: Facility Design

Search Result 2,682, Processing Time 0.032 seconds

Physico-Chemical Characteristics of Sediment in Sedimentation Tank of Infiltration Trench and Filtration System (비점오염저감시설인 침투도랑과 여과형 시설내 침강지 퇴적의 물리화학적 특성 분석)

  • Lee, Soyoung;Lee, Eun-Ju;Kim, Chulmin;Maniquiz, M.C.;Son, Youngkyu;Khim, Jeehyeong;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.9 no.3
    • /
    • pp.35-42
    • /
    • 2007
  • The paved areas such as parking lots and roads are stormwater intensive landuses since they are impervious and have high pollutant mass emissions from vehicular activity. Vehicle emissions include different pollutants such as heavy metals, oil and grease, particulates from sources such as fuels, brake pad wear and tire wear. Especially, the released heavy metals can be easily absorbed on the surface area of small particulate materials because of its ionic strength. Therefore, by constructing the sedimental tank in structural BMPs as a pre-treatment facility, the particles and heavy metals both can be removed from the runoff at an instant. To understand the physico-chemical characteristics of sediments from sedimentation tank, one-year study at an infiltration trench and filtration system was conducted to quantify the metal mass absorbed on sediments with various particle sizes. The structural BMPs for this study are located in Yongin City, Kyunggido. The research results show that Cu, Zn and Pb are dominant metal compounds in the sediments. Also the metal concentrations are highest at the ranges of $425-850{\mu}m$ particle sizes. The results will provide the basic physico-chemical information of sediments to treat it as solid wastes and to determine the design criteria of sedimentation tank in structural BMPs.

  • PDF

Hierarchical Analysis of the Application of U-Eco City Services in Urban Space -Focused on the Service Classification by Planning Factors and its Spatial Adaptability - (U-Eco City 서비스의 공간위계별 적용가능성 분석 -계획요소별 서비스 분류와 공간단위 적용성을 중심으로-)

  • Lee, Sangho;Leem, Yountaik;Kim, Heeyoung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.11
    • /
    • pp.458-468
    • /
    • 2012
  • The purpose of this study is to define U-Eco City services and to analyze the possibility and easiness of application in urban space. The most significant meaning of this study is that these results could be used as the design and planning guidelines for integrated U-Eco City. This study progress as follows; First, U-Eco City concept and their services were defined and the spatial units of U-Eco City were distinguished through literature review. Second, U-Eco City spaces are classified into four levels such as building, street, facility and district. Finally, the application of U-Eco city services was analyzed together by the statistical technique of cross-tabulation. 35.7% of U-city services was serviced in urban district and 38.8% of Eco City services was applied to Building. U-City and/or Eco city services were adapted differently according to the urban spatial hierarchy. Those services should be applied in terms of the characteristics of urban space in designing and planning U-Eco City.

Improvement of The National Technical Qualifications System from ICT point of view (ICT 관점에서 바라본 국가기술자격제도 개선)

  • Chang, Jin-Hyeon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.189-199
    • /
    • 2016
  • Pending issues present in the Nation Technical Qualifications System (NTQS) have been discussed to deal with the causes and improvements of the issues. The key present situations of the NTQS were investigated to analyze the problems of the NTQS. The acquisition distribution of the items of additional points in employment and the items applied to the laws and regulations of duty employment was revealed to be related with preferential items. The AHP analysis has been conducted based on issues for improvement of the NTQS raised till now. The urgency priority of the elements to be improved was ranked according to the AHP analysis result. The agendas for the improvement of the NTQS was suggested by consideration of the priority of the elements. First, a solution to raise discrimination of the NTQS was suggested by taking the view points of the experts into account. Second, an opinion was proposed that the preferential policies in employment should be directed toward expansion of qualification for duty employment. Third, two ideas were proposed to rectify problems embedded in the technician career handbook system. And four remedies have been made suggested, including the merger of similar events. The results of this research are expected to serve as a useful material for the future design of the NTQS.

Development of a Model of a Day Care Center for Rural Elderly People (농촌형 노인 주간보호시설 모형개발)

  • Kang, Kyung-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.4
    • /
    • pp.551-565
    • /
    • 2004
  • Purpose: The purpose of this study is to develop a day care center model focused on public health institutions for the elderly residing in their homes. Method: Research design for this study was a mult-level research, which consisted of a related literature review, an Internet search for knowledge of the current situation at home and abroad, on-site interviews, questionnaires collected from a sample of residents in a rural area, and a key-informants approach. Results: 1) The subjects of service - Generalized service should be provided to the elderly, 65 years and older, regardless of their assets. 2) The contents of service - Providing pre-health oriented and post-social welfare service that can integrate and satisfy a wide variety of public health and welfare needs of the elderly would strengthen the health care service of a day care center for the elderly. 3) Delivery system - Basic-level local self-governments should become a central operating body, and establishing a properly adjusted delivery system to a rural area after considering the efficiency and the access of vulnerable rural areas is needed based on modification of 'a Special Law for Agricultural and Fishery Areas' (rural public health center>rural health sub-center ${\rightarrow}$ unified health sub-center ${\rightarrow}$ public health hospital (public health center) ${\rightarrow}$ public welfare office). 4) Facility - Public health facilities such as public health centers and sub-centers should be located in areas that can easily access the facilities. 5) Funding - For day care center for the elderly in local self-government, the central government should modify a relevant implementation of subsidy in and provide some facilities and service regardless of the degree of self reliance of local self-government. 6) Human resources - It is needed to guarantee the period of workers of a day care center for the elderly, at least 3 to 5 years, with considering their specialty on aged care and avoiding circulation based positions. Furthermore, appropriate specially trained personnel such as medical workers and social workers should be placed to take care of both health service and welfare through strengthening of 'rules of law of elderly welfare,' Conclusion: future research is needed to test the model through a demonstration study using a model which may be developed in the future and to standardize the appraisal criteria of people hoping to enter a day care center for the elderly.

  • PDF

Seepage Behavior with Unsaturated Soil-Water Characteristic in Reclaimed Deep Excavation Area (해안매립지 대심도 굴착지역의 불포화 함수특성에 따른 침투류 거동)

  • Shin, Bang-Woong;Lee, Heung-Gil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.47-58
    • /
    • 2005
  • Development of underground space is conducted for various useful facility and underground structures and deep excavation technology for reclaimed area has been researched and developed. The seepage flow and behavior of phreatic line in reclaimed area was predominated by transient flow caused by tidal action. Also the soil-water characteristic relation is most important factor for transient flow analysis, therefore the research about the soil-water characteristic is strongly required. In this paper, laboratory tests (pressure cell, desiccator, and tensiometer test) and theoretical analysis were performed to investigate the soil-water characteristic such as air-entry value, metric suction, and residual water content. And the feasibility of prediction method for soil-water characteristic are presented by transient seepage analysis and comparison between analysis results and in-situ measured seepage flux in LNG TK-00 storage tank. Based on the result of laboratory and theoretical analysis, Fredlund and Xing's method provide to work out well for reclaimed ground soils. Also, the transient analysis result is more reasonable and effective for design of deep excavation work in coastal and reclaimed ground.

  • PDF

A Case Study on the Reinforcement of Existing Damaged Geogrid Reinforced Soil Wall Using Numerical Analyses (수치해석을 이용한 기존 피해 보강토 옹벽의 보강에 관한 사례 연구)

  • Won, Myoung-Soo;Langcuyan, Christine P.;Choi, Jeong-Ho;Ha, Yang-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.75-82
    • /
    • 2020
  • There have been often cases of collapse for geogrid reinforced soil (GRS) retaining wall. Hence, social interest in the reinforcement and restoration of the collapsed GRS wall is increasing day by day. However, there are only few researches. For this reason, a series of numerical analyses using the Plaxis 2D program was conducted in this study to analyze the suitable reinforcement methods that can be applied on the existing damaged GRS wall caused by overturning of the modular blocks facing and the surface settlement at the backfill as the results from the design failure. The restoration plan used in this study is composed of two cases: (Case 1) soil nailing reinforcement and reinforced concrete (RC) wall facing construction on the existing damaged GRS wall; and (Case 2) removal of the entire damaged GRS wall and then reconstruction. The results on the internal stability of the GRS wall show that Case 1 obtained a greater safety factor than Case 2 for tensile force while Case 2 had a greater safety factor than Case 1 for pullout failures. Case 1 was found to be more stable than Case 2 in terms of the global slope safety by shear strength reduction method and the external deformation behavior by numerical analysis. In this study, the existing damaged GRS wall which was reinforced using Case 1 method shows more stable external behavior.

Evaluation of Ballistic Resistance Performance by Thickness and Proportion of Magnetic Aggregate of Concrete (콘크리트 두께와 자철광 함량에 따른 방탄 성능 평가)

  • Lim, Cha-Yeon;Kim, Kuk-Joo;Roh, Jeong-Heon;Jang, Chang-Su;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.1
    • /
    • pp.43-51
    • /
    • 2020
  • The main purpose of protective facility for small military unit is to provide the protection of not all the weapons system but the near-miss bullet in Korean army. In particular about the small caliber bullets, especially KM80 in Korea, there were many studies that both of the experiential and structural design methods dose not reflect enough the military threat. For that reason, a new equation to calculate effective anti-piercing depths for RC slabs against small caliber bullets is proposed in earlier research with actual shooting test. But, the test only considers the strength of concrete without the thickness of concrete, types of aggregate, the angle of yaw of bullet, high-strength concrete, etc. Therefore, this study evaluated the ballistic resistance performance by thickness and proportion of magnetic aggregate of concrete. As a result, we identified two major statistical estimations that the error of piercing depth by the angle of yaw of bullet could be cancelled by barrage and the thickness and proportion of magnetic aggregate of concrete dose not effect on the protection ability of concrete structure.

Measurement of the Spatial Dose Rate for Distribution Room in Department of Nuclear Medicine (핵의학과 분배실 내의 공간선량률 측정)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • Even though the protective facility is well made with the development of medicine, the spatial dose within the radiation section could increase the exposure of the workers. The spatial dose is always present in distribution room within the Department of Nuclear Medicine, so the spatial dose of the interior distribution room is measured and analyzed for the prediction of the exposure dose. The spatial dose rate was $6.78{\pm}0.083{\mu}Sv/h$ in the $^{18}F$ distribution room of department of Nuclear Medicine, $9.248{\pm}0.013{\mu}Sv/h$ in $^{99m}Tc$, and $^{131}I$ distribution room. In addition, in case of $^{18}F$ distribution room, the yearly external exposure dose was $42.5{\mu}Sv$ when the nurse does IV in 1m in distance. It also showed that the spatial dose rate on the direction of right oblique showed higher than others by the standard of distribution window of distribution room. Therefore, the staying time of the workers should be short during distributing radiopharmaceuticals in the distribution room and the design of the distribution protection is necessary to reduce the exposure in the direction of right oblique of the protection. The utmost endeavors are required to reduce the worker's individual exposure dose while doing IV.

Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator (의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.109-113
    • /
    • 2002
  • In recent years, the radiotherapy equipment has become much more sophisticated, and with the complication comes an increased set of quality assurance (QA) responsibilities. Today's computer controlled linear accelerator requiring QA of not only the radiation integrity, but also the mechanical accuracy of the linear accelerator. The existing QA sheets are adequate for acceptance testing and commissioning but those sheets are somewhat descriptive form for routine QA. establishing the QA sheets for a facility are more efficient if the sheets could estimate the long-term stability for the result of QA. We are going to develope new prototype of mechanical QA sheet to visualize and to verify long-term stability of mechanical QA for clinical linear accelerator. The items included in mechanical QA sheet were 1) gantry rotation, 2) collimator rotation, 3) couch rotation, 4) optical distance indicator (ODI), and 5) laser alignment. We compared new prototype sheet with conventional sheet for several hospitals in Korea for those items. The QA acceptance criteria in this study mainly followed published recommendations. The contents of test for mechanical QA are the following. Confirm that the digital and/or mechanical gantry angle readouts are correct. Verify that digital and/or mechanical readouts of collimator angle agree with the true angle, as determined with the protractor. Measure the light field using a graph paper and compare with the digital readouts. Confirm digital readout accuracy. Verify that the sagittal laser, the left and right lasers, and the ceiling laser intersect at the isocenter. In the design of new QA sheet, we emphasized the representation of the long-term stability of mechanical QA by using Excel program. By using the new prototype QA sheet, we simplified and visualized the mechanical QA process, and could estimate the long-term stability of mechanical error of linear accelerator.

  • PDF

Analysis of Current Status and Teacher Librarians' Perception about Space Composition and Interior Environment of School Libraries (학교도서관 공간 영역 및 실내 환경 요소의 구성 현황과 사서 교사 인식 분석)

  • Song, Gi-Ho;Kang, Bong-Suk
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.31 no.1
    • /
    • pp.67-87
    • /
    • 2020
  • The purpose of this study is to analyze current status and teacher librarians' perceptions of school library space composition and indoor environment, and propose some methods for the school library to be a basic educational facility. The space most secured by the 126 teacher librarians who participated in the survey was the free reading area, and the space with the lowest level was the media production and group project area. The most important types of spaces for teacher librarians are the teaching area and the free reading area, while the recognition of the importance of media production and group project areas is relatively low. Among the elements of indoor environmental assessment, they showed that safety and comfort were the most important but diversity and flexibility were relatively less important. The result of this analysis is different from the school and library policy direction that emphasizes the learning commons and maker spaces. Teacher librarians still seem to appreciate the importance of traditional library space. Therefore, it is necessary to include the establishment and operation of maker spaces and learning commons in the teacher librarians training and retraining process. In addition, it is necessary to increase the participation of users such as teachers, students, and parents in space composition and interior design initiatives to increase the user's interior environment satisfaction.