Measurement of the Spatial Dose Rate for Distribution Room in Department of Nuclear Medicine

핵의학과 분배실 내의 공간선량률 측정

  • Received : 2012.03.27
  • Accepted : 2012.05.24
  • Published : 2012.06.30

Abstract

Even though the protective facility is well made with the development of medicine, the spatial dose within the radiation section could increase the exposure of the workers. The spatial dose is always present in distribution room within the Department of Nuclear Medicine, so the spatial dose of the interior distribution room is measured and analyzed for the prediction of the exposure dose. The spatial dose rate was $6.78{\pm}0.083{\mu}Sv/h$ in the $^{18}F$ distribution room of department of Nuclear Medicine, $9.248{\pm}0.013{\mu}Sv/h$ in $^{99m}Tc$, and $^{131}I$ distribution room. In addition, in case of $^{18}F$ distribution room, the yearly external exposure dose was $42.5{\mu}Sv$ when the nurse does IV in 1m in distance. It also showed that the spatial dose rate on the direction of right oblique showed higher than others by the standard of distribution window of distribution room. Therefore, the staying time of the workers should be short during distributing radiopharmaceuticals in the distribution room and the design of the distribution protection is necessary to reduce the exposure in the direction of right oblique of the protection. The utmost endeavors are required to reduce the worker's individual exposure dose while doing IV.

방사선 구역 내부의 공간선량은 의학의 발전과 더불어 방호시설이 잘 되어 있어도 작업종사자의 피폭을 증가시킬 우려가 있다. 핵의학과 내의 분배실은 항상 공간선량이 존재하므로 작업종사자의 피폭선량을 예측하기 위하여 분배실 내부의 공간선량을 측정, 분석 하였다. 핵의학과 $^{18}F$ 분배실의 공간선량률 측정결과 최대 $6.78{\pm}0.083{\mu}Sv/h$, $^{99m}Tc$, $^{131}I$ 분배실의 공간선량률이 최대 $9.248{\pm}0.013{\mu}Sv/h$로 나타났다. 또한, $^{18}F$ 분배실의 경우 1m 거리에서 간호사가 IV시 연간 외부피폭선량은 $42.5{\mu}Sv$로 나타났다. 분배실의 분배창을 기준으로 오른쪽 사방향에서 공간선량률이 높게 나타났다. 따라서 방사성의약품을 분배실에서 분배할 경우 방사선 작업종사자의 머무르는 시간을 짧게 해야 하며, 분배창의 오른쪽 사방향의 경우 피폭을 줄이기 위한 분배창의 설계가 필요하며, IV시 작업종사자의 개인피폭선량을 줄이기 위한 최선의 노력이 필요하다고 사료된다.

Keywords

References

  1. ICRP : "Recommendation of the International Commi ssion on Radiological Protection", ICRP Publication 26, Pergamon Press, Oxford, New York, 1977
  2. 한성규,전수경,정재성, 송서연 "핵의학과내의 공간별 선량률과 개인피폭선량과의 비교", 제 43차 방사선사 학술대회, pp446, 2008
  3. 佐藤孝司, 小野光ー:X線撮影空間の散亂線の擧動, 日本放射線技術学会論文誌, 第49巻, 第8号, p1383, 1993
  4. R. S. Sloboda, M. G. Schmid, and C.P. Willis : Technologist radiation exposures from nuclear medicine imaging procedures, J. Nucl. Med. Tech., 15, 16-24,1987
  5. M. Velchik : Radiation exposure associated with the performance of radiologic studies in radioactive patients, J. Nucl. Med. Tech, 18, pp211-213, 1990
  6. L.K. Harding, A. B. Mostafa, L. Roden, N. Williams : Dose rates from patients having nuclear medicine investigations, Nucl. Med. Common., 6, pp191-194,1985 https://doi.org/10.1097/00006231-198504000-00002
  7. 박명환.이준일,"핵의학 검사에서 환자로부터의 공간 선량률 측정", 대한방사선기술학회지 25(1), pp73-76, 2002
  8. 오현주 외 "X선 촬영실내에서의 공간산란선량 변동에 관한 연구", 대한 방사선기술학회지, 17(2), pp21-27,1994
  9. Jung - Min Kim, Sung Chul Kim X-ray dose at the time of diagnosis Thickness Cu filter to reduce by half, Radiology Technology, No. 24, pp17-22, 2001
  10. 강호윤 외 "휴대용 핵종분석기의 방향의존성 측정", 대구보건대학 학술대회 논문집, 2010
  11. 박명환, "전신 PET/CT 검사에서 공간선량률 측정", 대한방사선기술과학회지 29(4), pp257-260, 2006
  12. Nuclear Safety Commission Notice "on radiation pr otection standards, such as" No. 2011-29
  13. Gwang-yeol Yu "Sunshine electron emission due to the use of radionuclides in nuclear medicine labor atory safety management," Nuclear Technology 5 (2), pp280-287, 2000
  14. Byung - Joon Kwak, "PET-CT scan study on the spatial dose rate measurements," Pusan Catholic Un iversity School of Health Sciences, Master Thesis, 2009

Cited by

  1. Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS) vol.27, pp.3, 2016, https://doi.org/10.14316/pmp.2016.27.3.146
  2. The comparison of angular dependence for optical stimulated luminescence dosimeter(OSLD) and electronic personal dosimeter(EPD) used in Diagnostic Radiology vol.16, pp.3, 2015, https://doi.org/10.9728/dcs.2015.16.3.463
  3. Study on the Decommissioning of Small Nuclear Facility through Analyzing Foreign Decommissioning Practices vol.9, pp.3, 2015, https://doi.org/10.7742/jksr.2015.9.3.125
  4. 방사성동위원소 투여 시 차폐기구를 이용한 방사선 피폭 저감 vol.13, pp.2, 2012, https://doi.org/10.7742/jksr.2019.13.2.291